Break-even point
The sales volume at which total revenue equals total cost; calculated as fixed costs divided by the difference between unit selling price and unit variable cost.
Markup versus margin
Markup is the percentage added to cost, while margin is the percentage of the selling price; a 25 percent markup produces a 20 percent gross margin.
Working capital
Current assets minus current liabilities. It measures the funds available to cover day-to-day operations such as payroll, materials, and supplier payments.
Current ratio
Current assets divided by current liabilities. A ratio below 1.0 indicates the business cannot meet its short-term obligations with short-term assets.
Notice to Owner
A Florida written notice that a subcontractor or material supplier serves on the owner and lender within 45 days of first furnishing in order to preserve lien rights.
Change order
A written modification to a construction contract, signed by the owner and contractor, that changes the contract price, the contract time, or the scope of work.
Critical path
The longest chain of dependent activities in a project schedule. It sets the shortest possible project duration, and any delay on it delays completion.
Retainage
A percentage of each progress payment withheld by the owner until the work is complete. Florida limits public-work retainage to 5 percent after 50 percent completion.
Air gap
An unobstructed vertical distance between a potable water outlet and the flood-level rim of the receiving fixture; at least twice the pipe diameter and never less than 1 inch.
Trap seal depth
The vertical distance between the trap weir and the top of the trap dip; codes require a minimum of 2 inches and a maximum of 4 inches.
Vent through roof
A vent extending through a roof must terminate at least 6 inches above the roof surface, or 7 feet if the roof is used for purposes other than weather protection.
Water closet clearance
A water closet must have at least 15 inches from its centerline to any side wall and at least 30 inches of clear space between the surrounding walls.
Fixture unit
A unitless measure of the probable water demand of a plumbing fixture, used to size both water supply piping and drainage piping in a building.
Pressure per foot of rise
Each foot of elevation change in a water column equals 0.434 psi, so a 10-foot rise reduces static pressure by about 4.34 psi.
Water hammer arrestor
A device containing a trapped air chamber or piston, installed near quick-closing valves to absorb the shock wave created when flow stops suddenly.
Thermal expansion tank
A tank installed on the cold-water inlet of a water heater to absorb the volume increase when heated water expands in a closed system.
Drainage slope
Horizontal drainage pipe must slope at 1/4 inch per foot for 2-1/2 inch and smaller pipe and at 1/8 inch per foot for 3 inch and larger pipe.
Backwater valve
A one-way valve installed on a drain serving fixtures whose flood-level rim is below the next upstream manhole cover, preventing sewage backup into the building.
Cleanout placement
Cleanouts are required at the base of each stack, at the end of the building drain, and at changes of direction greater than 45 degrees.
Stack vent
The extension of a soil or waste stack above the highest fixture connection, which serves as the vent for the fixtures discharging into that stack.
Temperature and pressure relief valve
A valve on a water heater that opens at 210 degrees Fahrenheit or 150 psi to relieve excess temperature or pressure and prevent tank rupture.
Grease interceptor
A tank installed in the drain line from a food-service establishment that traps fats, oils, and grease and keeps them out of the building sewer.
Clothes washer standpipe
A vertical pipe that receives washing-machine discharge; it must be at least 18 inches and not more than 42 inches above the trap weir.
Trap primer
A device that automatically adds water to a floor drain trap to replace evaporation and keep the trap seal intact between periods of use.
Competent person
An individual who can identify existing and predictable hazards, is authorized to take prompt corrective action, and inspects excavations as required by OSHA.
Trench protective system
Sloping, benching, shoring, or a trench shield that protects workers; required in excavations 5 feet deep or more, or at any depth where hazards exist.
Fall protection height
In construction, employers must provide fall protection whenever workers are exposed to falls of 6 feet or more to a lower level.
Confined space oxygen
Acceptable atmospheric oxygen for entry is 19.5 to 23.5 percent; testing must occur before entry and continue while the space is occupied.
Quarter-inch scale
A drawing note of 1/4 inch = 1 foot means a measured quarter inch on paper represents one foot; multiply the scaled measurement by 48.
Cubic foot to gallons
One cubic foot contains 7.48 gallons of water, and one gallon of water weighs 8.34 pounds; use both factors to convert volume to weight.
Psi to feet of head
One psi equals 2.31 feet of water column, and one foot of head equals 0.433 psi; these convert between pressure and elevation.
Copper tube types
Type K has the thickest wall, Type L is medium, and Type M is thinnest; Type L is commonly used for interior water distribution piping.