FOA CFOS/H flashcards
FOA CFOS/H · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Single-mode fiber core size
- SMF has a core of about 8-10 µm and carries one propagation mode at 1310 and 1550 nm, giving low attenuation and long reach for PON and home backbone links.
- MMF core and use
- Multimode fiber has a 50 or 62.5 µm core, carries many modes, and works with 850 nm VCSELs for short in-home backbone runs, with higher attenuation than SMF.
- GPON wavelengths
- GPON uses 1310 nm upstream and 1490 nm downstream, with 1550 nm reserved for RF video overlay, so filters and splitters must pass the correct bands.
- XGS-PON wavelengths
- XGS-PON uses 1270 nm upstream and 1577 nm downstream at 10 Gbit/s symmetric, coexisting with GPON on the same ODN through wavelength-selective coexistence elements.
- Splitter insertion loss
- Splitter loss is fixed by ratio: about 3.5 dB for 1:2, 7.2 dB for 1:4, 10.5 dB for 1:8 and 17 dB for 1:32, and it applies in both directions.
- APC versus UPC polish
- APC ferrules are angled 8° and return about -60 dB reflectance, while UPC returns about -50 dB; mating APC to UPC causes high loss and can damage both endfaces.
- SC and LC connectors
- SC uses a 2.5 mm ferrule with a square push-pull body; LC uses a 1.25 mm ferrule in a small form factor, common at ONTs and high-density panels.
- Bend-insensitive fiber G.657
- ITU-T G.657.A1 and A2 fiber tolerates tight bends of about 5-10 mm radius, unlike standard G.652.D at about 30 mm, which matters for in-wall and corner routing.
- Cable jacket ratings
- OFNP plenum cable goes in air-handling spaces, OFNR riser cable in vertical shafts, and LSZH jackets reduce smoke and halogen release in dwellings.
- Minimum bend radius rule
- Keep at least 10 times the cable outer diameter under load and 20 times unloaded for standard cable; G.657 drop cable allows tighter radii but never below the manufacturer's stated minimum.
- Pull tension limit
- Indoor drop cable typically rates 50-100 N short-term and 25-50 N long-term; pull on the strength members, never on bare fiber, and avoid jerking.
- Fiber slack allowance
- Leave 1-3 m of slack at the ONT or outlet and a service loop at the entry point so the link can be re-terminated, re-spliced or moved later.
- Fusion splice procedure
- Strip and clean the fiber, cleave it squarely, align the ends in the splicer, arc-fuse, then protect the joint with a splice protector sleeve seated in the tray.
- Visual fault locator
- A VFL is a red laser that makes breaks, tight bends and bad connectors glow; it locates faults but does not measure loss in dB.
- OLTS reference method
- The reference method sets the zero point: one-cord for a simple link, two-cord for patch cords, three-cord when both ends need a reference connector; record which was used.
- OTDR launch cable
- A launch cable of 100-300 m lets the OTDR see the near-end connector and first events; set the correct IOR, wavelength and pulse width before testing.
- IEC 61300-3-35 zones
- This standard defines endface inspection zones (core, cladding, contact, ferrule) and pass/fail criteria for scratches, pits and contamination seen with a video probe.
- Loss budget formula
- Link loss equals fiber attenuation times length plus connector pairs times connector loss plus splices times splice loss plus splitter loss plus a design margin.
- GPON loss classes
- GPON Class B+ allows 28 dB optical distribution network loss and Class C+ allows 32 dB; compare the calculated budget against the class before design.
- ONT placement rules
- Place the ONT near the entry point on a power outlet, with ventilation, access for testing and reasonable Wi-Fi coverage; avoid basements and closed metal enclosures.
- As-built documentation
- The as-built package holds the topology drawing, cable schedule, loss budget, test reports, equipment serials and labels, and it is the reference for later changes.
- Spare fiber per drop
- Reserve at least one spare fiber or conduit per drop so a future 10G service or second provider can be added without opening finished walls.
- Cleaving quality effect
- A square cleave from a clean cleaver gives splice loss near 0.1 dB; a chipped or angled cleave causes high loss or a failed splice and must be re-cleaved.
- Polarity test for duplex
- Duplex links must be checked A-to-B and B-to-A with a source and meter or VFL pair; reversed polarity shows as no light at the receiver.
- Macrobend symptom
- A tight bend adds loss that is worse at 1550 nm than at 1310 nm and often disappears when the cable is straightened, which distinguishes it from a bad splice.
- OTDR event signatures
- A reflective spike indicates a connector, a non-reflective step indicates a splice or bend, and the event distance is compared with the cable schedule to locate it.
- Field-installable connector loss
- Field-installable connectors typically show 0.5-0.75 dB insertion loss, higher than factory pigtails fusion-spliced at about 0.1-0.3 dB, so budget accordingly.
- Firestopping penetration rule
- Seal every penetration through fire-rated walls and floors with listed materials and use the jacket rating required by the space to keep the fire separation intact.
- Design margin rule
- Keep at least 3 dB of margin in the loss budget to cover aging, repairs, temperature variation and connectors added after the initial installation.
- Fiber scrap safety
- Cleaved fiber scraps are sharps: keep a labeled waste container, wear safety glasses when cleaving, and never leave scraps on floors or in clothing.
- Laser eye hazard
- Never look into a fiber end or unmated connector; infrared light at 1310 and 1550 nm is invisible and can damage the retina even at modest power.
- Acceptance handover gate
- Before handover confirm every link passes the loss budget, polarity is correct, labels match the as-built, and signed test reports are delivered to the owner.