31 cards. Read the term and the definition here. The deck at the top of this page is optional.

Total internal reflection
The confinement of light in the core when it strikes the core-cladding boundary above the critical angle; requires the core refractive index to exceed the cladding index.
Numerical aperture
A measure of a fiber's light-gathering ability, computed as the square root of n_core squared minus n_cladding squared; it equals the sine of the maximum acceptance angle.
Graded-index multimode
Multimode fiber whose core refractive index decreases gradually toward the cladding, reducing modal dispersion and raising bandwidth compared with step-index multimode.
Attenuation formula
Loss in decibels equals ten times the base-10 logarithm of input power divided by output power; fiber attenuation is normally stated in dB per kilometer.
Single-mode core size
Single-mode fiber uses a core of roughly 8 to 10 micrometers inside a 125-micrometer cladding, allowing only one propagation mode at the operating wavelengths.
Horizontal cabling limit
The permanent horizontal cable run from the telecommunications room to the work area is limited to 90 meters within a 100-meter channel that includes patch cords.
Plenum-rated cable
Cable with low-smoke, low-flame-spread jacket materials, marked CMP or OFNP, permitted in air-handling spaces where smoke propagation must be minimized.
APC versus UPC polish
APC connectors use an 8-degree angled ferrule with better return loss than flat UPC; the two polish types must never be mated because of high loss and damage risk.
LC connector
A small-form-factor fiber connector with a 1.25-millimeter ferrule and a push-pull latch, commonly used for high-density patch panels and equipment ports.
MPO connector
A multi-fiber push-on connector holding 8 to 24 fibers in a single ferrule, used for parallel optics and high-density backbone or data center links.
OM3 and OM4 fiber
Laser-optimized 50-micrometer multimode fiber types; OM4 has higher bandwidth and supports longer 10-gigabit distances than OM3.
Tight-buffered cable
Indoor fiber cable construction with a protective buffer applied directly to each fiber, allowing direct field connectorization and flexible routing inside buildings.
Fiber color code order
The standard 12-fiber sequence is blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, and aqua, repeated with tracers for higher counts.
Pull tension limit
The maximum force allowed on cable during installation, set by the manufacturer; tight-buffered indoor fiber is commonly limited to about 25 pounds-force.
Bend radius rule
Cable must not be bent tighter than about 20 times its diameter during installation or 10 times its diameter after installation, per manufacturer and standard requirements.
Service loop
Extra cable slack of at least one meter left at each end and in enclosures so the cable can be reterminated or rerouted without pulling a new run.
Firestopping
A listed system that restores the fire rating of a floor or wall where cable penetrates it; required at every rated penetration and recorded in documentation.
Cable labeling
Unique identifiers applied to both ends of every cable and to individual fiber strands before pulling, matched to the cable schedule and as-built records.
Tier 1 testing
Fiber testing with a light source and power meter to measure insertion loss and length; it confirms that a link meets its loss budget.
Tier 2 testing
Tier 1 testing plus an optical time-domain reflectometer trace that locates splices, connectors, and faults along the fiber for detailed analysis.
Reference method
The one-, two-, or three-jumper setup used to zero the test equipment before measuring; it determines whether connector loss is included in results.
End-face inspection
Examining every connector with a magnification scope before mating to detect contamination, scratches, or pits that cause loss and permanent damage.
Loss budget formula
Total allowed loss equals fiber attenuation times length plus splice losses plus connector losses plus a margin, commonly three decibels for aging and future repairs.
OTDR launch cable
A known-length fiber (typically 100 meters or more) attached before the fiber under test so the near-end connector and first events can be measured accurately.
Insertion loss
The reduction in optical power caused by a component such as a connector or splice, measured in decibels as the difference between input and output power.
Channel length model
The 100-meter channel consists of 90 meters of horizontal cable plus up to 5 meters at the work area and 5 meters in the telecommunications room.
10GBASE-SR distance
A 10-gigabit multimode standard reaching about 300 meters on OM3 and 400 meters on OM4 fiber at 850 nanometers.
10GBASE-LR distance
A 10-gigabit single-mode standard operating at 1310 nanometers and supporting links up to 10 kilometers on OS2 fiber.
As-built documentation
Closeout records including cable schedules, strand assignments, rack elevations, test reports, and firestop records that reflect the installed cable plant.
Change control
A written process requiring approval and an updated drawing before any deviation from the design, such as altered routing, connector type, or fiber count.
Site survey
A pre-design walkthrough recording distances, pathways, access, power, and obstructions so the cabling design and bill of materials reflect actual conditions.