FOA CFOS/W study materials
FOA CFOS/W study resources

Cascaded splitter proposed for an 8-home extension

FOA CFOS/W · Put your knowledge to work in context.

All case studies

Cascaded splitter proposed for an 8-home extension

A 96-home subdivision is served by an FDT containing four 1:32 splitters (128 ports), with 12 FATs of 8 homes each. A developer adds an 8-home cul-de-sac 480 m beyond FAT-12. FAT-12 is full. The FDT has 32 unused splitter ports and two unused PON ports on the OLT; 12 spare feeder fibers reach the FDT. The designer proposes feeding a new 1:8 splitter at a new FAT-13 from one spare 1:32 splitter port, creating a 1:32 + 1:8 cascade. The installer says this is cheaper than a new 12-fiber cable and an OLT port, and argues that the extra splitter only costs 10.5 dB, and we have 28 dB. The developer wants service in six weeks. Class B+ optics are used throughout; the longest existing link measures 22.1 dB.

1. Calculate whether the proposed 1:32 + 1:8 cascade closes the optical budget.

Read the worked answer

Use the standard values and add every element:

  • 1:32 splitter: 17.0 dB
  • 1:8 splitter: 10.5 dB
  • 480 m fiber at 0.35 dB/km: 0.17 dB
  • Connectors, two mated pairs: about 0.6 dB
  • Splices, three: about 0.3 dB
  • Total: about 28.6 dB

The Class B+ budget is 28 dB, so the cascade fails even before any aging margin. Adding the normal 3 dB planning margin makes it clearly unacceptable. The installer compared 10.5 dB with a 28 dB budget but ignored the existing 17 dB splitter and the feeder loss already consumed upstream. This is not a close call.

A 1:32 + 1:4 cascade would total about 25.3 dB, which fits on paper, but it serves only four homes and leaves only 2.7 dB of margin before aging - still a poor design choice.

2. Recommend a compliant design and justify the port and fiber use.

Read the worked answer

Run a new 12-fiber cable 480 m from the FDT to a new FAT-13 and install a 1:8 splitter there, fed directly from one of the two unused OLT PON ports through one spare feeder fiber.

Loss for that path:

  • 1:8 splitter: 10.5 dB
  • 480 m fiber: 0.17 dB
  • Connectors: 0.6 dB
  • Splices: 0.3 dB
  • Total: about 11.6 dB

This leaves more than 16 dB of budget for future growth and aging. It uses one OLT port and one feeder fiber, leaving one OLT port and 11 feeder fibers spare at the FDT. The new cable also provides spare fibers for future homes or business services. The extra cost of 480 m of cable and a few splices is justified because the cascade cannot be certified. Do not consume a 1:32 splitter port for a single subscriber drop when eight homes need service; that wastes capacity and still fails the budget.

3. What if no OLT PON port were available? What fallback would you evaluate?

Read the worked answer

If no OLT port were available, the only way to serve eight homes from existing 1:32 ports would be two 1:4 splitters at FAT-13, each fed by a separate spare 1:32 port. Each path would be 17.0 + 7.2 + 0.17 + 0.9 ≈ 25.3 dB, leaving about 2.7 dB against the 28 dB budget. That is marginal once temperature, aging, and repair margin are considered, and it consumes two scarce 1:32 ports for eight homes.

A better fallback is to rebalance the subdivision: move an existing 1:8 FAT onto a new 1:8 splitter fed from a spare OLT port, freeing a 1:32 port, or negotiate a new OLT card. The key judgment is that a cascade which totals 28.6 dB cannot be rescued by calling it a temporary solution. It will produce intermittent ONTs and repeated truck rolls.