Optical Line Terminal (OLT)

The service-provider endpoint of a PON that sits in the central office or headend, aggregates subscriber traffic, manages ONTs, and drives the downstream and upstream optical signals on each PON port.

Related: Optical Network Unit (ONU), PON Port, Passive Optical Network (PON)
Optical Network Unit (ONU)

The subscriber-side device that terminates the PON fiber, converts between optical and electrical signals, and delivers Ethernet or voice services to the customer's premises equipment.

Related: Optical Network Terminal (ONT), Optical Line Terminal (OLT), Power Budget
Optical Network Terminal (ONT)

A single-subscriber ONU, usually mounted at the home, that converts the PON optical signal into the customer's service interfaces such as Ethernet, Wi-Fi, and analog phone ports.

Related: Optical Network Unit (ONU), Demarcation Point
Passive Optical Network (PON)

A point-to-multipoint fiber architecture in which unpowered splitters fan one feeder fiber out to many subscribers, sharing the OLT port's bandwidth and reducing outside-plant electronics.

Related: Optical Splitter, Feeder Cable, Optical Line Terminal (OLT)
GPON

An ITU-T PON standard using 2.488 Gbit/s downstream and 1.244 Gbit/s upstream with fixed-length GTC frames, supporting up to 128 splits and multiple service types over one fiber.

Related: XGS-PON, Optical Splitter, Passive Optical Network (PON)
XGS-PON

Symmetric 10 Gbit/s PON standard (ITU-T G.9807.1) that can coexist with GPON on the same outside plant by using a different downstream wavelength, easing upgrades without re-splicing the ODN.

Related: GPON, Wavelength Division Multiplexing (WDM), Optical Distribution Network (ODN)
Optical Distribution Network (ODN)

The passive portion of a PON between the OLT and the ONTs, comprising feeder, distribution, and drop cables plus splitters, connectors, and closures that together define the optical loss.

Related: Feeder Cable, Distribution Cable, Optical Splitter
Feeder Cable

The high-fiber-count cable running from the central office to the first splitting or distribution point, carrying all subscribers' traffic on shared fibers before any branching occurs.

Related: Distribution Cable, Optical Splitter, Optical Distribution Network (ODN)
Distribution Cable

The cable segment between the splitter or distribution hub and the access points near subscribers, typically with fewer fibers than the feeder and routed through pedestals or closures.

Related: Feeder Cable, Drop Cable, Fiber Distribution Hub (FDH)
Drop Cable

The final short cable from an access terminal, closure, or splitter port to the subscriber premises, often a small-diameter or ruggedized single-fiber cable designed for aerial or buried routing.

Related: Distribution Cable, Demarcation Point, Optical Network Terminal (ONT)
Fiber Distribution Hub (FDH)

A cabinet or enclosure where feeder fibers are spliced to splitters and distribution fibers, providing cross-connect, splitting, and test access points in the outside plant.

Related: Optical Splitter, Feeder Cable, Distribution Cable
Optical Splitter

A passive component that divides one optical input among several outputs, commonly in 1x2, 1x4, 1x8, 1x16, or 1x32 ratios, each stage adding insertion loss to the optical budget.

Related: Insertion Loss, Power Budget, Optical Distribution Network (ODN)
Insertion Loss

The optical power lost when a component such as a connector, splice, or splitter is inserted into a link, expressed in decibels as the ratio of output to input power.

Related: Optical Splitter, Return Loss, Power Budget
Return Loss

A measure in decibels of how much optical power is reflected back toward the source at a connector, splice, or fiber end, with higher values indicating cleaner, better-matched terminations.

Related: Insertion Loss, Optical Time Domain Reflectometer (OTDR), Connector Polish
Power Budget

The allowable optical loss between transmitter and receiver, calculated from launch power minus receiver sensitivity, which must exceed total fiber, splice, connector, and splitter losses.

Related: Insertion Loss, Optical Splitter, Optical Link Loss
Optical Link Loss

The measured or calculated total attenuation of a complete fiber path from OLT to ONT, including cable attenuation, splice loss, connector loss, and splitter loss.

Related: Power Budget, Insertion Loss, Optical Time Domain Reflectometer (OTDR)
Optical Time Domain Reflectometer (OTDR)

A test instrument that launches light pulses into a fiber and graphs backscatter and reflections versus distance, revealing splice and connector loss, breaks, bends, and overall link attenuation.

Related: Event Dead Zone, Optical Link Loss, Return Loss
Event Dead Zone

The minimum fiber distance after a reflective event over which an OTDR can still detect and measure a following event, shortened by narrower pulses but traded against dynamic range.

Related: Optical Time Domain Reflectometer (OTDR), Attenuation Dead Zone, Splice Loss
Attenuation Dead Zone

The distance after a reflective event over which an OTDR can accurately measure loss of a subsequent non-reflective event, a key specification when testing closely spaced splices or connectors.

Related: Event Dead Zone, Optical Time Domain Reflectometer (OTDR), Splice Loss
Optical Power Meter (OPM)

A calibrated instrument that reads absolute or relative optical power at a given wavelength, used to verify transmitter output and receiver input levels during activation and troubleshooting.

Related: Optical Light Source, Optical Loss Test Set (OLTS), Power Budget
Optical Loss Test Set (OLTS)

A paired light source and power meter used to measure end-to-end insertion loss of a fiber link at one or more wavelengths, typically following a reference or one-jumper method.

Related: Optical Power Meter (OPM), Optical Light Source, Optical Link Loss
Optical Light Source

A stabilized laser or LED transmitter emitting at a defined wavelength, such as 1310, 1490, or 1550 nm, paired with a power meter for loss testing.

Related: Optical Power Meter (OPM), Optical Loss Test Set (OLTS)
Fusion Splicing

Joining two fibers permanently by aligning and fusing their cleaved ends with an electric arc, producing a low-loss, low-reflection joint protected by a splice protector sleeve.

Related: Mechanical Splice, Splice Loss, Cleaving
Mechanical Splice

A field-installable device that aligns and holds two cleaved fibers together, often with index-matching gel, giving a quick but generally higher-loss joint than fusion splicing.

Related: Fusion Splicing, Splice Loss
Splice Loss

The optical attenuation contributed by a splice, typically a few tenths of a decibel for fusion splices, caused by core misalignment, end quality, or mode-field mismatch.

Related: Fusion Splicing, Insertion Loss, Cleaving
Cleaving

Scoring and breaking a fiber to produce a flat, perpendicular end face within a tight angle tolerance, a prerequisite for low-loss splicing and reliable connector termination.

Related: Fusion Splicing, Connector Polish
Connector Polish

The end-face geometry of a fiber connector, such as PC, UPC, or APC, where APC's angled, typically green, ferrule reduces back-reflection and must not be mated with flat-polish connectors.

Related: Return Loss, Insertion Loss, Cleaving
SC Connector

A push-pull square-bodied fiber connector with a 2.5 mm ferrule, widely used on PON ports, splitters, and ONTs because it latches securely and is easy to field-mate.

Related: LC Connector, Connector Polish
LC Connector

A small-form-factor connector with a 1.25 mm ferrule and latch, common on high-density patch panels and equipment ports where space and port count matter.

Related: SC Connector, Patch Panel
Bend-Insensitive Fiber

Single-mode fiber designed with a depressed cladding or trench to confine light tightly, allowing tight cable bends at drop and in-home routing without excessive macrobend loss.

Related: Macrobending, Drop Cable
Macrobending

Radiated loss caused by bending fiber beyond its minimum bend radius, showing up as increased attenuation at longer wavelengths and often as a distinct loss event on an OTDR trace.

Related: Bend-Insensitive Fiber, Optical Time Domain Reflectometer (OTDR)
Wavelength Division Multiplexing (WDM)

Combining multiple optical signals at different wavelengths onto one fiber, used in FTTH to carry separate services or to overlay GPON and XGS-PON traffic on shared outside plant.

Related: XGS-PON, GPON
Aerial Fiber Installation

Stringing fiber cable on poles, using strand, lashed or ADSS cable, with attention to sag, clearance, and messenger attachment so the cable is not over-tensioned or abraded.

Related: Drop Cable, Minimum Bend Radius
Minimum Bend Radius

The tightest curvature a cable or fiber may be subjected to without damage or excess loss, usually stated as a multiple of cable diameter and enforced during pulling and storage.

Related: Macrobending, Bend-Insensitive Fiber, Aerial Fiber Installation
Demarcation Point

The boundary where the provider's outside-plant responsibility ends and the customer's premises wiring begins, commonly at the ONT or an external enclosure and important for fault isolation.

Related: Optical Network Terminal (ONT), Drop Cable
Patch Panel

A rack- or wall-mounted assembly of adapter ports that terminates incoming fibers and allows flexible cross-connection via patch cords, simplifying moves, adds, and testing.

Related: LC Connector, Pigtail
Pigtail

A short factory-terminated fiber with a connector on one end and bare fiber on the other, fusion spliced to a cable fiber to provide a reliable connectorized end.

Related: Fusion Splicing, Patch Panel
PON Port

A single optical interface on the OLT serving one PON branch, with a defined split ratio and power budget; its count and split sizing drive the network's subscriber capacity.

Related: Optical Line Terminal (OLT), Optical Splitter, Power Budget