- Critical angle
- The minimum incidence angle at which light in the core is totally internally reflected at the cladding boundary; it depends on the refractive indices of core and cladding.
- Numerical aperture
- A measure of the range of angles over which a fiber accepts light; single-mode fiber has a small NA, multimode a larger one.
- Modal dispersion
- Pulse spreading in multimode fiber caused by different modes traveling different path lengths; graded-index profiles reduce it, and it is absent in single-mode fiber.
- Chromatic dispersion
- Pulse spreading because different wavelengths travel at slightly different speeds; it affects all fibers and is minimized near 1310 nm in standard single-mode fiber.
- APC connector
- An angled physical contact connector with an 8-degree polished endface, usually green, offering lower reflectance than UPC; it must never be mated to a UPC connector.
- Fusion splice
- A permanent joint made by electrically arcing two prepared fiber ends together; typical loss is about 0.05 to 0.1 dB.
- WDM
- Wavelength division multiplexing sends multiple signals on separate wavelengths over one fiber; CWDM uses wide spacing and DWDM tight spacing for high capacity.
- Single-mode fiber
- Fiber with an approximately 8 to 10 micrometer core and small numerical aperture that carries one mode, giving low loss and long reach at 1310 and 1550 nm.
- Horizontal cabling limit
- The permanent horizontal link is limited to 90 meters, with up to 10 meters of patch cords, for a 100-meter maximum channel length.
- Plenum cable rating
- OFNP cable is rated for air-handling spaces and has low smoke and flame spread; it is required in plenums instead of riser-rated OFNR cable.
- Minimum bend radius
- The smallest radius a cable may be bent without damage or loss; commonly 10 times the cable diameter during installation and per manufacturer spec after installation.
- Entrance facility
- The point where outside plant cable enters a building and transitions to indoor-rated cable, typically within 15 meters of the entry point.
- OM3 and OM4
- Laser-optimized multimode fiber grades, usually aqua-jacketed, supporting 10 Gigabit Ethernet to roughly 300 and 400 meters respectively.
- Backbone cabling
- Cabling that connects entrance facilities, equipment rooms, and telecommunications rooms; it usually uses higher fiber counts and includes spare strands.
- ADSS cable
- All-dielectric self-supporting cable used for aerial spans without a messenger strand; it carries its own mechanical load and resists electrical interference.
- Loose-tube cable
- Outside plant cable design in which fibers sit in gel-filled or dry buffer tubes, protecting them from moisture and allowing length changes with temperature.
- Splice closure
- A re-enterable housing that protects fusion splices in outside plant; types include inline, butt, and dome closures sealed with gel or heat shrink.
- Tracer wire
- A wire installed alongside buried fiber so metallic locating equipment can find the route, since optical fiber itself cannot be detected by locators.
- Bidirectional OTDR testing
- Testing a span from both ends and averaging the results, which removes errors caused by differing backscatter coefficients at splices and events.
- Duct fill ratio
- The percentage of a conduit's cross-section occupied by cable; keeping it around 40 to 50 percent or less leaves room for pulling and future cables.
- Power budget
- The difference between transmitter output power and receiver sensitivity; it must exceed total link loss plus a margin, typically 3 dB, for the link to work.
- Link loss calculation
- Total loss equals connector count times connector loss, plus splice count times splice loss, plus fiber length times attenuation at the operating wavelength.
- PON split ratio
- The number of subscribers sharing one feeder fiber, commonly 1:32 or 1:64; a 1:32 splitter adds roughly 16 to 17 dB of loss to the budget.
- Diverse routing
- Designing physically separate cable paths so a single cut, fire, or construction event cannot disable both working and protection paths.
- Optical margin
- Extra loss allowance added to a design, often 3 dB, to cover aging, repairs, additional splices, and measurement uncertainty over the system life.
- One-jumper reference
- A test method using a single reference cord at each end, yielding lower measured loss than two- or three-jumper methods; the method must be reported with results.
- OTDR dead zone
- The distance after a reflective event where the OTDR cannot detect another event; shorter pulse widths reduce dead zones but shorten measurement range.
- Index of refraction setting
- The IOR value entered in an OTDR, taken from the cable manufacturer; an incorrect value makes all reported distances inaccurate.
- Visual fault locator
- A visible red laser tool that reveals breaks, tight bends, and damaged connectors by glowing at the fault; it does not measure loss.
- GPON wavelengths
- Gigabit PON uses 1490 nm downstream, 1310 nm upstream, and 1550 nm for optional video overlay, with 2.488 Gbps down and 1.244 Gbps up.
- XGS-PON
- A symmetric 10 Gbps PON standard using 1577 nm downstream and 1270 nm upstream, able to coexist with GPON on the same fiber via wavelength multiplexing.
- Optical network terminal
- The subscriber-side device in an FTTH network that converts optical signals to electrical service; receive power must fall within the PON optics window.
- Drop cable
- The small fiber cable, often one or two strands, running from the splitter or pedestal to the subscriber's ONT; it must be protected from tight bends and UV.