Bac STI2D - independent subject practice study materials
Bac STI2D - independent subject practice study resources

Bac STI2D - independent subject practice cheat sheet

Bac STI2D - independent subject practice · Keep the key ideas within reach.

Quick reference

Engineering models, drawings, evidence and project decisions

  • State the system boundary and assumptions before calculation.

  • Units, sign conventions and uncertainty are part of the answer.

  • Verification against a specification differs from validation for an intended use.

  • Drawings need a declared convention and controlled revision.

  • Classroom models do not authorize physical operation or structural approval.

Quick reference

Materials, testing and selection

  • Engineering stress σ = F/S₀ uses original area; E = σ/ε applies to the linear elastic region. Engineering stress itself is not confined to that region.

  • Toughness = whole curve area; resilience = elastic area

  • Hardness is not fundamental but correlates with strength

  • Grain refinement commonly increases yield strength in conventional metallic microstructures, subject to material and scale limits.

  • Selection needs specific indices (σ/ρ, E/ρ) plus cost and durability

Quick reference

Building systems, load paths, heat and moisture

  • R=d/λ uses thickness in metres; total resistance includes the model’s surfaces and layers.

  • U=1/R_total is a steady-state element model, not the complete building energy demand.

  • Permanent, occupancy, wind and snow actions require the stated design framework.

  • Moisture, airtightness and intended ventilation must be considered together.

  • Example tie spacing is supplied data, not a code rule.

Quick reference

Energy, thermal machines and environmental assessment

  • 1 kWh = 3.6 MJ; 1 tep ≈ 41.86 GJ

  • Conversion efficiency must use a consistent useful output and input; it differs from a heat pump coefficient of performance, which can exceed one.

  • Carnot heat-engine efficiency is1−T_cold/T_hot using kelvin and the stated hot/cold reservoirs.

  • Hydro: P = η·ρ·g·Q·H

  • Wind power grows with v³; Betz limit C_p = 0.593

  • Sustainability is assessed per kWh: CO₂, life cycle, energy mix

Quick reference

Electrical circuits, machines and digital logic

  • For a sinusoid V_rms = V_peak/√2; the stated impedance magnitude is for a series RLC model.

  • Q_C = P(tan φ₁ − tan φ₂) for power-factor correction

  • Transformer: V₁/V₂ = N₁/N₂ = I₂/I₁

  • Induction motor: n = (1 − s)·60f/p

  • Thévenin voltage is open-circuit voltage; deactivate independent sources to obtain resistance while preserving dependent-source behavior.

  • Karnaugh: give the minimum sum of products

Quick reference

Measurement, feedback, PLC and automation

  • Sensitivity = Δoutput/Δinput; resolution = smallest detectable change

  • Closed-loop error compares reference and measurement; integral action can remove appropriate steady-state error only under suitable stability and operating assumptions.

  • PLC scan: read inputs → run program → update outputs

  • 4–20 mA live zero: (I − 4)/16 of the span

  • Repeatability ≠ accuracy, resolution ≠ sensitivity

  • Robot DOF come from its joints; workspace is the reachable volume

Quick reference

Computing Systems

  • Fetch-decode-execute uses the PC, IR, ALU, and registers.

  • Memory hierarchy: registers, cache, RAM, storage, offline.

  • RAM is volatile; SSDs retain data without power.

  • A process has its own address space; threads share one.

  • Authentication verifies identity; authorization grants permissions.

  • TCP is reliable and connection-oriented; UDP is connectionless and lower overhead.

  • IP addresses route between networks; MAC addresses work on the local link.

  • A /26 subnet has 64 addresses and 62 usable hosts.

  • DNS resolves names; DHCP assigns addresses.

  • Security protects data; privacy governs collection and use.

Quick reference

Calculus

  • Chain rule: never drop the inner derivative g'(x).

  • Integration by parts: choose u so du is simpler than u.

  • Change limits immediately when substituting in a definite integral.

  • Improper integrals require an explicit limit, not direct substitution.

  • Implicit differentiation collects dy/dx terms after differentiating both sides.

Quick reference

Algebra and Functions

  • State domain restrictions before simplifying; cancelled factors still exclude values.

  • Composition f(g(x)) is evaluated inside-out and is generally not commutative.

  • Inverses require one-to-one functions; domain and range swap.

  • Horizontal transformations act opposite to the sign or factor shown.

  • Log laws convert sums to products, enabling solution of log equations.

  • Always check candidate solutions against original domain restrictions.

Quick reference

Physical chemistry, amounts, reactions and equilibria

  • n = m/M, n = cV (V in dm3) and n = V/24.0 for gases at RTP are the three key conversions.

  • The limiting reagent is the one with the smallest moles ÷ coefficient; product amount depends on it.

  • Percentage yield measures practical success; atom economy measures how much reactant mass is useful.

  • Dilution uses c1V1 = c2V2 because the moles of solute do not change.

  • Always balance the equation before applying any molar ratio.

  • ΔH is negative for exothermic reactions; standard enthalpy of formation of an element in its standard state is zero.

  • q = mcΔT uses the total mass of solution, and ΔH per mole = −q/n.

  • Hess's law lets you combine any route; combustion data are used in the reverse order to formation data.

  • ΔH = Σ bonds broken − Σ bonds formed, and mean bond enthalpies are averages.

  • Feasibility is determined by ΔG = ΔH − TΔS, not by ΔH alone.

  • Orders are determined experimentally, not from stoichiometric coefficients.

  • Rate constant units depend on overall order: for second order overall, dm3 mol−1 s−1; for third order overall, dm6 mol−2 s−1.