FRA Signal Employee flashcards
FRA Signal Employee · Build recall with a focused review session.
34 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Fail-Safe Principle
- Any component failure, loss of energy, or broken wire must drive a signal system to its most restrictive aspect. Vital relays are energized for the permissive condition so that dropping out produces stop.
- Ohm's Law in Signal Circuits
- E = I × R, with P = I²R. Track lead, relay coil, and lamp resistance all add to the circuit; the current must still exceed pickup and fall below drop-away at the worst-case supply voltage.
- Relay Pickup and Drop-Away
- Pickup is the current at which a relay energizes; drop-away is the lower current at which it releases. Vital relays are tested to the release value because a partially stuck relay can hold a false clear.
- Vital Versus Non-Vital Circuit
- Vital circuits affect train movement and must be fail-safe and immune to single-component failure. Non-vital circuits, such as indications and alarms, may use standard industrial logic without fail-safe design.
- Coded Track Circuit
- A track circuit that alternates its energization in a code pattern to convey aspect information. Loss of code for the set interval is interpreted as occupancy or a broken rail, so the decoder drops to the restrictive state.
- Standard Shunt Test
- A specified resistance, commonly 0.06 ohm, applied across the rails to simulate a train. The track relay must drop at both the near and far ends of the circuit for the test to pass.
- Broken Rail Protection
- A properly designed track circuit loses current when a rail breaks, dropping the track relay to the restrictive state. The far-end shunt test verifies that this protection actually functions.
- Impedance Bond Function
- In electrified territory, an impedance bond carries propulsion return current around insulated joints while maintaining track circuit balance. A failed bond unbalances the circuit and can cause false operation.
- Insulated Joint Failure
- Insulated joints separate adjacent track circuits. A shorted or failed joint can bridge two circuits, producing a false clear or false occupancy that must be tested and reported as a defect.
- Constant Warning Time
- A grade crossing predictor measures train speed and distance to compute a consistent warning interval, commonly about 20 seconds, before the train reaches the crossing, regardless of train speed.
- Island Circuit
- The short track circuit at a grade crossing that detects a train occupying the crossing. Loss of island detection can cause gates to rise on a train, which is a critical defect.
- Grade Crossing Gate Timing
- Gates descend only after flashing lights and the bell start, and rise after the train clears the island plus a set delay. Timing is verified during inspection and recorded.
- Crossing Battery Backup
- Grade crossing warning systems require a primary supply and a battery backup sized for a specified operating period. Low battery or charger failure is a reportable defect under Part 234.
- Highway Signal Interconnection
- Preemption links a nearby highway traffic signal to the crossing so traffic clears before gates descend. A failed interconnection is a defect because vehicles may be trapped on the crossing.
- Route Locking
- An interlocking function that holds a cleared route so conflicting routes cannot be established while a train occupies or approaches it. Locking releases only when the route is proven clear.
- Switch Point Detection
- A circuit controller proves the switch points are fully seated in normal or reverse before a signal can clear. A broken detector rod or unseated point is a false-clear hazard.
- Part 236 Scope
- 49 CFR Part 236 sets the rules, standards, and instructions for signal systems, including required periodic inspections and tests and the records that must document them.
- Part 235 Malfunction Report
- Part 235 requires reporting signal malfunctions that affect train movement, including the cause and corrective action, within the regulatory time limit.
- Interim Protection for Defects
- When a safety device is defective and cannot be restored immediately, the affected movement is protected by restricting speed, flagging, or taking the signal out of service until repair is verified.
- Foul Time
- A dispatcher-granted period during which a worker may occupy a track with protection from train movements. The worker must not foul the track before receiving it and must release it when done.
- Watchman/Lookout Duty
- A lookout is positioned to see approaching trains and warn workers in time to clear, using a whistle or horn. Restricted sight distance requires additional lookouts or foul time.
- Job Briefing Content
- Before work, the briefing covers location, tracks affected, train movements, working limits, and the protection method. Workers must understand and acknowledge it before fouling any track.
- Lone Worker On-Track Safety
- An individual worker must establish on-track safety, such as train approach warning or foul time, before fouling a track. Walking near tracks without protection is prohibited.
- Lead-Acid Battery Hazard
- Lead-acid batteries contain corrosive electrolyte and lead, and charging produces explosive hydrogen gas. Use PPE, ventilate the area, avoid sparks, and neutralize spills with the approved agent.
- Safety Data Sheet Access
- An SDS must be available for every hazardous material on site, including batteries, solvents, and cleaners. Workers must know the hazards, handling, and first aid before use.
- Capacitor Stored Energy
- Signal capacitors can retain a charge after power is removed. Discharge them and verify zero voltage before handling, or the worker may receive a shock from stored energy.
- Hazardous Waste Shipping
- Batteries and other regulated waste shipped off site must be packaged, labeled, and manifested per DOT rules, with shipping papers prepared by a trained employee.
- Lockout/Tagout Steps
- Isolate every energy source, apply a personal lock and tag, and verify zero energy by testing for voltage. Only the person who applied the lock may remove it.
- Test Before Touch
- Verify the voltage tester on a known live source, test the circuit, then re-verify the tester. A failed tester can give a false dead reading and cause a shock.
- Voltage-Rated Gloves
- Rubber insulating gloves must be rated for the voltage class of the work, inspected before each use, and removed from service if damaged. Leather protectors are worn over them.
- Signal Test Record Content
- Each record must identify the device, location, date, test performed, results, and tester, and must be legible and retained for the required period. Missing or altered records are defects.
- Defect Closure Verification
- A defect is not closed until the repair is verified by a test that proves the failure mode is corrected. The log shows discovery, interim protection, repair, and verification.
- PTC Enforcement
- PTC enforces movement authority and speed profiles; exceeding the profile or passing a stop point triggers a penalty brake application. It is a safety overlay, not a replacement for signals.
- PTC Wayside Interface
- Signal aspects and switch positions feed the PTC onboard system. A failed interface must be detected so authority is not granted beyond what the signal system permits.