Georgia Low Voltage Practice key terms
Georgia Low Voltage Practice · Get comfortable with the vocabulary.
- Ohm's Law
- Related: Voltage Drop, Power Formula (Watts Law)
The fixed relationship among voltage, current, and resistance in a circuit, expressed as voltage equals current times resistance. Knowing any two values lets you calculate the third for troubleshooting and sizing conductors.
- Power Formula (Watts Law)
- Related: Ohm's Law, Class 2 Circuit
The relationship stating that electrical power in watts equals voltage multiplied by current, with a power-factor correction for alternating-current loads. Used to estimate load on circuits and power supplies.
- Voltage Drop
- Related: Ohm's Law, AWG (American Wire Gauge)
The loss of voltage along a conductor caused by its resistance, which increases with length, current, and smaller wire size. Excessive drop causes devices to malfunction and is limited by design guidelines.
- AWG (American Wire Gauge)
- Related: Voltage Drop, Conductor Fill
The standard numbering system for conductor size in North America, where smaller numbers indicate larger conductors. Common low voltage sizes include 22, 18, 16, and 14 AWG.
- Class 2 Circuit
- Related: Class 3 Circuit, Power-Limited Circuit
A circuit supplied by a listed limited-power source, such as a transformer or power supply, that limits energy to levels considered safe for fire and shock under normal conditions. Most low voltage signaling and control wiring falls in this category.
- Class 3 Circuit
- Related: Class 2 Circuit, Power-Limited Circuit
A circuit supplied by a listed power source with energy limits higher than Class 2 but still controlled, used for certain remote-control and signaling applications. Its wiring rules differ from Class 2 in separation and permitted uses.
- Power-Limited Circuit
- Related: Class 2 Circuit, Class 3 Circuit
A circuit whose source is listed and restricts available energy to safe levels, allowing reduced wiring methods and fewer protection requirements. The installer must confirm the source listing rather than assume from low voltage alone.
- Plenum
- Related: CMP (Plenum-Rated Cable), Riser
A space used for air handling, such as above a suspended ceiling that serves as a return-air path. Cable installed there must have a plenum rating because of fire and smoke concerns.
- CMP (Plenum-Rated Cable)
- Related: Plenum, CMR (Riser-Rated Cable)
A communications cable listing indicating low smoke and flame spread, suitable for installation in ducts and plenums. It is the most restrictive and typically most expensive jacket rating.
- CMR (Riser-Rated Cable)
- Related: Riser, CMP (Plenum-Rated Cable)
A communications cable listing intended for vertical runs between floors in shafts, offering flame resistance for riser applications. It is not permitted in plenums unless also plenum rated.
- Riser
- Related: CMR (Riser-Rated Cable), Plenum
A vertical pathway, such as a shaft or chase, that carries cables between floors of a building. Cables installed there must carry the appropriate riser rating.
- Conductor Fill
- Related: AWG (American Wire Gauge), Pull Tension
The percentage of a raceway's internal cross-section occupied by cables or conductors. Limits keep pulling tension reasonable and prevent heat buildup or damage during installation.
- Pull Tension
- Related: Conductor Fill, Bend Radius
The longitudinal force applied to a cable while pulling it through a raceway or conduit. Exceeding the manufacturer's limit stretches conductors, changes impedance, and degrades data performance.
- Bend Radius
- Related: Pull Tension, Cable Category
The minimum curve a cable can tolerate without damage, usually stated as a multiple of its outer diameter. Violating it kinks conductors, cracks insulation, and degrades signal performance.
- Cable Category
- Related: Permanent Link, Crosstalk
A performance classification for twisted-pair cable and components, such as Category 5e, 6, or 6A, specifying supported frequencies and data rates. Higher categories demand tighter installation and testing tolerances.
- Permanent Link
- Related: Channel, Cable Category
The installed portion of a cabling run from the work-area outlet to the patch panel, excluding patch cords. It is the standard test configuration for verifying installed performance.
- Channel
- Related: Permanent Link, Cable Category
The complete end-to-end signal path, including the permanent link plus patch cords at both ends. Channel testing reflects real-world performance but is less repeatable than link testing.
- Crosstalk
- Related: Cable Category, Permanent Link
Unwanted signal coupling from one pair or cable to another, measured as near-end or far-end values. It is the primary impairment in twisted-pair cabling and is controlled by twist rates and installation care.
- TIA-568
- Related: Cable Category, Permanent Link
The widely adopted North American standard series governing commercial structured cabling design, installation, and performance. It defines cable categories, distances, topologies, and test requirements.
- Topology (Star)
- Related: Horizontal Cabling, Patch Panel
A cabling layout in which each work area connects by a dedicated cable to a central distribution point. It supports easy moves, adds, and changes and is the basis of structured cabling standards.
- Horizontal Cabling
- Related: Topology (Star), Patch Panel
The cabling from the telecommunications room to work-area outlets on the same floor, limited in length by standards. It excludes backbone and patch cords in its length budget.
- Patch Panel
- Related: Horizontal Cabling, Permanent Link
A rack-mounted assembly of ports where horizontal cables terminate and are cross-connected to network equipment. It provides organization, labeling, and flexibility for changes.
- Fire Alarm Control Panel (FACP)
- Related: Initiating Device Circuit, Notification Appliance Circuit (NAC)
The central unit that monitors initiating devices, controls notification appliances, and reports system status and alarms. It may be conventional, addressable, or networked, and its programming must match the approved design.
- Initiating Device Circuit
- Related: Fire Alarm Control Panel (FACP), Addressable Device
The wiring loop connecting detectors and manual pull stations to the fire alarm panel. Conventional circuits report by zone, while addressable circuits identify individual devices.
- Notification Appliance Circuit (NAC)
- Related: Voltage Drop, Supervision (Circuit)
The circuit that powers horns, strobes, and speakers, requiring supervision and adequate voltage at the end of the line. Voltage drop calculations are critical because appliances must operate at their listed minimum.
- Addressable Device
- Related: Initiating Device Circuit, Signaling Line Circuit
A detector, module, or appliance that has its own unique address on a signaling line circuit, allowing individual identification. Addressable systems simplify troubleshooting and support detailed annunciation.
- Signaling Line Circuit
- Related: Addressable Device, Supervision (Circuit)
The addressable data and power pathway connecting intelligent devices to the fire alarm panel. It requires specific cable types and supervision to detect opens, shorts, and ground faults.
- Supervision (Circuit)
- Related: Signaling Line Circuit, Notification Appliance Circuit (NAC)
A monitoring method that detects opens, shorts, or ground faults on wiring so a failure is annunciated rather than silently disabling protection. It is required for most fire alarm and life safety circuits.
- Surge Protective Device (SPD)
- Related: Grounding Electrode System, Equipotential Bonding
A component that shunts or clamps transient overvoltages to protect equipment, rated by surge current capacity and clamping voltage. Proper installation requires short, low-impedance leads and correct grounding.
- Grounding Electrode System
- Related: Bonding Jumper, Equipotential Bonding
The set of electrodes, such as rods, plates, or building steel, that establishes a connection to earth. It provides a reference and path for lightning and fault currents.
- Bonding Jumper
- Related: Equipotential Bonding, Grounding Electrode System
A conductor that intentionally connects metal parts to ensure electrical continuity and equal potential. It is distinct from a grounding conductor, which carries current to earth.
- Equipotential Bonding
- Related: Bonding Jumper, Surge Protective Device (SPD)
Connecting conductive surfaces together so they sit at the same potential, preventing dangerous voltage differences. It is essential in communications rooms and around sensitive electronics.
- Ground Fault
- Related: Supervision (Circuit), Bonding Jumper
An unintended path from a current-carrying conductor to earth or metalwork, which can cause shock, fire, or nuisance tripping. Ground fault detection is required on many fire alarm circuits.
- Lockout/Tagout
- Related: Personal Protective Equipment (PPE), Confined Space
A safety procedure that isolates energy sources and applies locks and tags to prevent unexpected energization during work. Only the person who applied the lock should remove it under normal circumstances.
- Personal Protective Equipment (PPE)
- Related: Lockout/Tagout, Confined Space
Wearable safety gear such as eye protection, gloves, and hard hats selected for the hazards of the task. It supplements, but never replaces, safe work practices and engineering controls.
- Confined Space
- Related: Lockout/Tagout, Personal Protective Equipment (PPE)
A space with limited entry or exit that is not designed for continuous occupancy, such as a vault or crawlspace. Entry may require atmospheric testing, a permit, and an attendant.
- Ladder Safety
- Related: Personal Protective Equipment (PPE), Confined Space
The set of practices for selecting, setting, and using ladders, including the four-to-one angle rule and three-point contact. It prevents falls, the leading cause of serious injury in the trade.
- Permit and Licensing Board
- Related: Low Voltage Contractor License, Continuing Education
The Georgia state board that issues licenses for electrical and low voltage contractors and enforces qualification requirements. It sets examination, insurance, and continuing education rules.
- Low Voltage Contractor License
- Related: Permit and Licensing Board, Qualifying Agent
The Georgia credential authorizing a business to contract for low voltage work such as alarm, communications, and control systems. It generally requires a qualifying agent, insurance, and board approval.
- Qualifying Agent
- Related: Low Voltage Contractor License, Continuing Education
An individual who holds the required license and is responsible for the technical competence and code compliance of a contracting business. The business license depends on that person's standing.
- Continuing Education
- Related: Qualifying Agent, Permit and Licensing Board
Required periodic training hours that license holders complete to renew their credential and stay current. Hours must come from approved providers and be documented for audit.
- Contract and Lien Rights
- Related: Permit and Licensing Board, Low Voltage Contractor License
The legal framework in Georgia governing written agreements, payment terms, and a contractor's ability to place a lien for unpaid work. Missing notices or deadlines can forfeit those rights.