Georgia Low Voltage Practice · Get comfortable with the vocabulary.

Ohm's Law

The fixed relationship among voltage, current, and resistance in a circuit, expressed as voltage equals current times resistance. Knowing any two values lets you calculate the third for troubleshooting and sizing conductors.

Related: Voltage Drop, Power Formula (Watts Law)
Power Formula (Watts Law)

The relationship stating that electrical power in watts equals voltage multiplied by current, with a power-factor correction for alternating-current loads. Used to estimate load on circuits and power supplies.

Related: Ohm's Law, Class 2 Circuit
Voltage Drop

The loss of voltage along a conductor caused by its resistance, which increases with length, current, and smaller wire size. Excessive drop causes devices to malfunction and is limited by design guidelines.

Related: Ohm's Law, AWG (American Wire Gauge)
AWG (American Wire Gauge)

The standard numbering system for conductor size in North America, where smaller numbers indicate larger conductors. Common low voltage sizes include 22, 18, 16, and 14 AWG.

Related: Voltage Drop, Conductor Fill
Class 2 Circuit

A circuit supplied by a listed limited-power source, such as a transformer or power supply, that limits energy to levels considered safe for fire and shock under normal conditions. Most low voltage signaling and control wiring falls in this category.

Related: Class 3 Circuit, Power-Limited Circuit
Class 3 Circuit

A circuit supplied by a listed power source with energy limits higher than Class 2 but still controlled, used for certain remote-control and signaling applications. Its wiring rules differ from Class 2 in separation and permitted uses.

Related: Class 2 Circuit, Power-Limited Circuit
Power-Limited Circuit

A circuit whose source is listed and restricts available energy to safe levels, allowing reduced wiring methods and fewer protection requirements. The installer must confirm the source listing rather than assume from low voltage alone.

Related: Class 2 Circuit, Class 3 Circuit
Plenum

A space used for air handling, such as above a suspended ceiling that serves as a return-air path. Cable installed there must have a plenum rating because of fire and smoke concerns.

Related: CMP (Plenum-Rated Cable), Riser
CMP (Plenum-Rated Cable)

A communications cable listing indicating low smoke and flame spread, suitable for installation in ducts and plenums. It is the most restrictive and typically most expensive jacket rating.

Related: Plenum, CMR (Riser-Rated Cable)
CMR (Riser-Rated Cable)

A communications cable listing intended for vertical runs between floors in shafts, offering flame resistance for riser applications. It is not permitted in plenums unless also plenum rated.

Related: Riser, CMP (Plenum-Rated Cable)
Riser

A vertical pathway, such as a shaft or chase, that carries cables between floors of a building. Cables installed there must carry the appropriate riser rating.

Related: CMR (Riser-Rated Cable), Plenum
Conductor Fill

The percentage of a raceway's internal cross-section occupied by cables or conductors. Limits keep pulling tension reasonable and prevent heat buildup or damage during installation.

Related: AWG (American Wire Gauge), Pull Tension
Pull Tension

The longitudinal force applied to a cable while pulling it through a raceway or conduit. Exceeding the manufacturer's limit stretches conductors, changes impedance, and degrades data performance.

Related: Conductor Fill, Bend Radius
Bend Radius

The minimum curve a cable can tolerate without damage, usually stated as a multiple of its outer diameter. Violating it kinks conductors, cracks insulation, and degrades signal performance.

Related: Pull Tension, Cable Category
Cable Category

A performance classification for twisted-pair cable and components, such as Category 5e, 6, or 6A, specifying supported frequencies and data rates. Higher categories demand tighter installation and testing tolerances.

Related: Permanent Link, Crosstalk
Permanent Link

The installed portion of a cabling run from the work-area outlet to the patch panel, excluding patch cords. It is the standard test configuration for verifying installed performance.

Related: Channel, Cable Category
Channel

The complete end-to-end signal path, including the permanent link plus patch cords at both ends. Channel testing reflects real-world performance but is less repeatable than link testing.

Related: Permanent Link, Cable Category
Crosstalk

Unwanted signal coupling from one pair or cable to another, measured as near-end or far-end values. It is the primary impairment in twisted-pair cabling and is controlled by twist rates and installation care.

Related: Cable Category, Permanent Link
TIA-568

The widely adopted North American standard series governing commercial structured cabling design, installation, and performance. It defines cable categories, distances, topologies, and test requirements.

Related: Cable Category, Permanent Link
Topology (Star)

A cabling layout in which each work area connects by a dedicated cable to a central distribution point. It supports easy moves, adds, and changes and is the basis of structured cabling standards.

Related: Horizontal Cabling, Patch Panel
Horizontal Cabling

The cabling from the telecommunications room to work-area outlets on the same floor, limited in length by standards. It excludes backbone and patch cords in its length budget.

Related: Topology (Star), Patch Panel
Patch Panel

A rack-mounted assembly of ports where horizontal cables terminate and are cross-connected to network equipment. It provides organization, labeling, and flexibility for changes.

Related: Horizontal Cabling, Permanent Link
Fire Alarm Control Panel (FACP)

The central unit that monitors initiating devices, controls notification appliances, and reports system status and alarms. It may be conventional, addressable, or networked, and its programming must match the approved design.

Related: Initiating Device Circuit, Notification Appliance Circuit (NAC)
Initiating Device Circuit

The wiring loop connecting detectors and manual pull stations to the fire alarm panel. Conventional circuits report by zone, while addressable circuits identify individual devices.

Related: Fire Alarm Control Panel (FACP), Addressable Device
Notification Appliance Circuit (NAC)

The circuit that powers horns, strobes, and speakers, requiring supervision and adequate voltage at the end of the line. Voltage drop calculations are critical because appliances must operate at their listed minimum.

Related: Voltage Drop, Supervision (Circuit)
Addressable Device

A detector, module, or appliance that has its own unique address on a signaling line circuit, allowing individual identification. Addressable systems simplify troubleshooting and support detailed annunciation.

Related: Initiating Device Circuit, Signaling Line Circuit
Signaling Line Circuit

The addressable data and power pathway connecting intelligent devices to the fire alarm panel. It requires specific cable types and supervision to detect opens, shorts, and ground faults.

Related: Addressable Device, Supervision (Circuit)
Supervision (Circuit)

A monitoring method that detects opens, shorts, or ground faults on wiring so a failure is annunciated rather than silently disabling protection. It is required for most fire alarm and life safety circuits.

Related: Signaling Line Circuit, Notification Appliance Circuit (NAC)
Surge Protective Device (SPD)

A component that shunts or clamps transient overvoltages to protect equipment, rated by surge current capacity and clamping voltage. Proper installation requires short, low-impedance leads and correct grounding.

Related: Grounding Electrode System, Equipotential Bonding
Grounding Electrode System

The set of electrodes, such as rods, plates, or building steel, that establishes a connection to earth. It provides a reference and path for lightning and fault currents.

Related: Bonding Jumper, Equipotential Bonding
Bonding Jumper

A conductor that intentionally connects metal parts to ensure electrical continuity and equal potential. It is distinct from a grounding conductor, which carries current to earth.

Related: Equipotential Bonding, Grounding Electrode System
Equipotential Bonding

Connecting conductive surfaces together so they sit at the same potential, preventing dangerous voltage differences. It is essential in communications rooms and around sensitive electronics.

Related: Bonding Jumper, Surge Protective Device (SPD)
Ground Fault

An unintended path from a current-carrying conductor to earth or metalwork, which can cause shock, fire, or nuisance tripping. Ground fault detection is required on many fire alarm circuits.

Related: Supervision (Circuit), Bonding Jumper
Lockout/Tagout

A safety procedure that isolates energy sources and applies locks and tags to prevent unexpected energization during work. Only the person who applied the lock should remove it under normal circumstances.

Related: Personal Protective Equipment (PPE), Confined Space
Personal Protective Equipment (PPE)

Wearable safety gear such as eye protection, gloves, and hard hats selected for the hazards of the task. It supplements, but never replaces, safe work practices and engineering controls.

Related: Lockout/Tagout, Confined Space
Confined Space

A space with limited entry or exit that is not designed for continuous occupancy, such as a vault or crawlspace. Entry may require atmospheric testing, a permit, and an attendant.

Related: Lockout/Tagout, Personal Protective Equipment (PPE)
Ladder Safety

The set of practices for selecting, setting, and using ladders, including the four-to-one angle rule and three-point contact. It prevents falls, the leading cause of serious injury in the trade.

Related: Personal Protective Equipment (PPE), Confined Space
Permit and Licensing Board

The Georgia state board that issues licenses for electrical and low voltage contractors and enforces qualification requirements. It sets examination, insurance, and continuing education rules.

Related: Low Voltage Contractor License, Continuing Education
Low Voltage Contractor License

The Georgia credential authorizing a business to contract for low voltage work such as alarm, communications, and control systems. It generally requires a qualifying agent, insurance, and board approval.

Related: Permit and Licensing Board, Qualifying Agent
Qualifying Agent

An individual who holds the required license and is responsible for the technical competence and code compliance of a contracting business. The business license depends on that person's standing.

Related: Low Voltage Contractor License, Continuing Education
Continuing Education

Required periodic training hours that license holders complete to renew their credential and stay current. Hours must come from approved providers and be documented for audit.

Related: Qualifying Agent, Permit and Licensing Board
Contract and Lien Rights

The legal framework in Georgia governing written agreements, payment terms, and a contractor's ability to place a lien for unpaid work. Missing notices or deadlines can forfeit those rights.

Related: Permit and Licensing Board, Low Voltage Contractor License