gh-ec-electrical-wiring-industrial key terms
gh-ec-electrical-wiring-industrial · Get comfortable with the vocabulary.
- Ground-fault circuit interrupter (GFCI)
- Related: Equipment grounding conductor, Arc-fault circuit interrupter (AFCI)
A protective device that compares current leaving and returning on a circuit and opens the circuit when the imbalance exceeds a few milliamps, limiting electric shock risk to people.
- Equipment grounding conductor
- Related: Ground-fault circuit interrupter (GFCI), Grounding electrode conductor
The conductor that bonds non-current-carrying metal parts of equipment to the system grounding point, providing a low-impedance fault path so overcurrent devices clear faults quickly.
- Grounding electrode conductor
- Related: Equipment grounding conductor, Bonding jumper
The conductor that connects the grounded circuit conductor or equipment grounding system to the grounding electrode, establishing a reference to earth potential.
- Bonding jumper
- Related: Grounding electrode conductor, Equipment grounding conductor
A conductor sized to ensure electrical continuity between metal parts, used to connect raceways, enclosures, or electrodes so they remain at the same potential.
- Overcurrent protective device (OCPD)
- Related: Time-current curve, Series rated system
A fuse or circuit breaker that opens a circuit when current exceeds a set value for a set time, protecting conductors and equipment from overheating and fault damage.
- Time-current curve
- Related: Selective coordination, Overcurrent protective device (OCPD)
A graph showing how long a protective device takes to open at various current levels, used to coordinate devices so only the nearest one trips during a fault.
- Selective coordination
- Related: Time-current curve, Series rated system
The intentional arrangement of overcurrent devices so that the device closest to a fault opens first, leaving upstream devices closed and minimizing outage scope.
- Series rated system
- Related: Interrupting rating, Selective coordination
A combination of a main breaker and downstream breakers tested together so the downstream device may have a lower interrupting rating than the available fault current, relying on the main to assist.
- Interrupting rating
- Related: Series rated system, Available fault current
The maximum short-circuit current a device is rated to safely clear at a stated voltage, expressed in kiloamps, without failing or endangering personnel.
- Available fault current
- Related: Interrupting rating, Impedance (transformer percent impedance)
The maximum short-circuit current a system can deliver at a given point, determined by utility capacity, transformer impedance, and conductor impedance, used to select adequately rated equipment.
- Impedance (transformer percent impedance)
- Related: Available fault current, Voltage drop
The voltage drop across a transformer winding at rated current, expressed as a percentage of rated voltage; it limits short-circuit current and affects voltage regulation.
- Voltage drop
- Related: Conductor ampacity, Impedance (transformer percent impedance)
The reduction in voltage along a circuit caused by conductor resistance and reactance carrying current; excessive drop causes poor equipment performance and motor overheating.
- Conductor ampacity
- Related: Ampacity adjustment factors, Voltage drop
The maximum continuous current a conductor can carry under stated conditions without exceeding its temperature rating, adjusted for ambient temperature and number of current-carrying conductors.
- Ampacity adjustment factors
- Related: Conductor ampacity, Raceway fill
Derating multipliers applied to a conductor's tabulated ampacity when ambient temperature differs from the table basis or when multiple current-carrying conductors share a raceway.
- Raceway fill
- Related: Ampacity adjustment factors, Conduit body
The percentage of a raceway's cross-sectional area occupied by conductors, limited by code to keep conductors from jamming and to allow heat dissipation.
- Conduit body
- Related: Raceway fill, Box fill calculation
A fitting installed in a conduit run that provides access for pulling conductors and making splices or bends, with volume limits on contained conductors.
- Box fill calculation
- Related: Conduit body, Pull box sizing
The method of counting conductors, devices, fittings, and grounding conductors by volume allowances to confirm an enclosure is large enough for its contents.
- Pull box sizing
- Related: Box fill calculation, Conduit body
The rules that set minimum dimensions for junction and pull boxes based on conduit trade size and whether the run is straight or angled, ensuring conductors can be pulled without damage.
- Continuous load
- Related: Overcurrent protective device (OCPD), Demand factor
A load expected to operate at maximum current for three hours or more, requiring conductors and overcurrent devices to be sized at 125 percent of the load.
- Demand factor
- Related: Continuous load, Load calculation
The ratio of the maximum demand of a system to the total connected load, allowing feeders and services to be sized smaller than the sum of all loads.
- Load calculation
- Related: Demand factor, Continuous load
A structured method of summing general lighting, receptacle, appliance, and motor loads with applicable demand factors to determine feeder and service capacity.
- Motor branch-circuit short-circuit and ground-fault protection
- Related: Motor overload protection, Full-load current (FLC)
The overcurrent device protecting a motor branch circuit against short circuits and grounds, sized from motor full-load current using code tables rather than conductor ampacity.
- Motor overload protection
- Related: Motor branch-circuit short-circuit and ground-fault protection, Full-load current (FLC)
A device that senses sustained excess current in a motor and opens the circuit to prevent winding damage from overheating, separate from short-circuit protection.
- Full-load current (FLC)
- Related: Motor overload protection, Motor branch-circuit short-circuit and ground-fault protection
The current a motor draws at rated load and voltage, taken from code tables or the nameplate, used to size branch-circuit conductors and protective devices.
- Motor controller
- Related: Across-the-line starter, Variable frequency drive (VFD)
A device or assembly that starts and stops a motor and may provide overload protection, speed control, or reversing functions, rated for the motor's voltage and horsepower.
- Across-the-line starter
- Related: Motor controller, Variable frequency drive (VFD)
A motor controller that connects the motor directly to the supply at full voltage through contactors, providing simple start-stop control and overload protection.
- Variable frequency drive (VFD)
- Related: Motor controller, Harmonics
An electronic controller that varies motor speed by changing supply frequency and voltage, often used for energy savings and process control, with special cable and grounding requirements.
- Harmonics
- Related: Variable frequency drive (VFD), Power factor
Voltages or currents at integer multiples of the fundamental frequency, produced by nonlinear loads such as drives and rectifiers, causing conductor heating and neutral overload.
- Power factor
- Related: Harmonics, Demand factor
The ratio of real power in watts to apparent power in volt-amperes, indicating how much current is doing useful work versus circulating as reactive current.
- Hazardous (classified) location
- Related: Class/Division system, Intrinsic safety
An area where flammable gases, vapors, dusts, or fibers may be present in quantities sufficient to ignite, requiring special equipment and wiring methods.
- Class/Division system
- Related: Zone classification system, Hazardous (classified) location
The traditional classification scheme that groups hazardous materials by class and rates the likelihood of their presence by division, guiding equipment selection and installation rules.
- Zone classification system
- Related: Class/Division system, Intrinsic safety
An international scheme that classifies gas and dust hazards by zone numbers reflecting how often or how long an ignitable atmosphere is expected to exist.
- Intrinsic safety
- Related: Hazardous (classified) location, Explosionproof enclosure
A protection method that limits electrical energy in a circuit to levels too low to ignite a hazardous atmosphere, using barriers or isolators and special wiring rules.
- Explosionproof enclosure
- Related: Intrinsic safety, Hazardous (classified) location
An enclosure designed to contain an internal explosion and prevent ignition of surrounding flammable atmosphere, with flame paths that cool escaping gases.
- Arc-fault circuit interrupter (AFCI)
- Related: Ground-fault circuit interrupter (GFCI), Overcurrent protective device (OCPD)
A device that detects the current and voltage signature of arcing and opens the circuit to reduce the chance of fire from damaged wiring or connections.
- Working space (clearance)
- Related: Lockout/tagout (LOTO), Arc flash boundary
The clear area required in front of electrical equipment, with depth based on voltage and condition, so workers can safely operate and service energized parts.
- Arc flash boundary
- Related: Working space (clearance), Lockout/tagout (LOTO)
The distance from energized equipment within which a person could receive a second-degree burn from an arcing fault, used to select protective clothing.
- Lockout/tagout (LOTO)
- Related: Working space (clearance), Arc flash boundary
A procedure that isolates energy sources with locks and tags before work, preventing accidental energization or release of stored energy during maintenance.
- Approved
- Related: Working space (clearance), Hazardous (classified) location
Acceptable to the authority having jurisdiction, typically because a product is listed by a recognized testing laboratory or meets an established safety standard.