HAAG Roof Inspector · Keep the key ideas within reach.

Quick reference

Residential Roofing

  • Slope is rise over run expressed as X:12; slope ratio = rise ÷ 12. Roofs below 3:12 generally require a full underlayment system and are treated as low-slope by most shingle manufacturers.

  • Asphalt shingle minimum slope is typically 2:12 with double underlayment; 4:12 and steeper may use a single layer. Always confirm the specific manufacturer's published installation instructions, which govern over generic rules.

  • Attic ventilation balance rule: total net free vent area (NFVA) is split roughly 50/50 between intake (soffit/eave) and exhaust (ridge/static). Net free area is the vent's stated NFVA, not its gross opening size.

  • Ice dam control: ice barrier membrane is required along eaves in cold climates, extending from the eave edge inward to at least 24 inches past the interior line of the exterior wall.

  • Flashing failure points on residential roofs: step flashing at sidewalls, counterflashing at chimneys, valley metal, pipe boots, and kick-out flashing where a roof meets a wall above a lower roof.

  • Fastener rules for asphalt shingles: nails must penetrate at least 3/4 inch into solid decking or through the deck; high-nail placement (above the nail line) is a common cause of shingle blow-off and is a defect.

  • Decking: minimum 5/8-inch plywood or OSB is common; gaps between panels of 1/8 inch allow expansion. Soft, delaminated, or rotted decking must be replaced, not covered.

  • Valley types: open metal valley, closed-cut valley, and woven valley. Closed-cut and woven are not permitted on slopes below the manufacturer's stated minimum for those methods.

Quick reference

Commercial Roofing

  • Low-slope commercial roofs are defined as less than 3:12 (some codes use 2:12 as the membrane threshold); steep-slope is 3:12 and above. Membrane selection follows slope, not just building type.

  • TPO and PVC are thermoplastic single-ply membranes joined by hot-air welding; EPDM is thermoset and joined with adhesive or tape. Weld seams are tested with a probe or seam tester, not by visual inspection alone.

  • Modified bitumen is applied in plies (often base plus cap sheet) by torch, hot-mop, or self-adhered methods. Torch application requires a fire watch and is restricted near combustibles.

  • Built-up roofing (BUR) consists of alternating layers of felt and bitumen topped with surfacing (gravel, cap sheet, or coating). Ply count and surfacing determine the membrane's durability and warranty class.

  • Roof drains and scuppers: primary drainage plus secondary (emergency) drainage is required by code on most commercial roofs. Ponding water is a defect when it persists more than 48 hours after rain.

  • Insulation attachment: mechanically fastened, adhered, or ballasted. Ballasted systems rely on paver or aggregate weight and require a perimeter zone with additional ballast for wind uplift resistance.

  • Roof curbs, expansion joints, and penetration details require a minimum 8-inch curb height above the roof surface for many HVAC units, and flashing height is measured from the finished roof surface, not the deck.

  • Recover vs. tear-off: a recover adds a new membrane over the existing roof; most codes limit to one recover and require tear-off when the existing roof is wet, blistered, or already has two layers.

Quick reference

Wind Damage

  • Wind pressure on a roof is proportional to the square of wind speed (dynamic pressure q = 0.00256 × V² in psf at standard conditions). Doubling wind speed quadruples the pressure.

  • Roof zones for wind uplift: field, edge, and corner. Corner zones see the highest uplift coefficients, edge zones next, field lowest. Damage patterns follow these zones.

  • Uplift is negative pressure: wind flowing over a roof creates suction that pulls the covering upward. Missing shingles or membrane are often torn, not pushed in, and creased or flipped tabs indicate uplift.

  • Fastener pull-through and shiner (missed nail) patterns are the leading causes of wind blow-off on shingle roofs. Shiner nails and high nails are installation defects, not storm damage.

  • Wind-borne debris causes impact damage (dents, punctures, granule loss). Impact marks on metal or membrane, and granule displacement on shingles, are documented with close-up photos and measurements.

  • Membrane billowing and seam peel on single-ply roofs are wind damage indicators. Check seam edges for peeling, and check perimeter edge metal for lifting, fastener withdrawal, and deformation.

  • Direction of damage helps establish wind direction: shingles torn from the windward edge and creased toward leeward, or edge metal bent in the direction of flow. Document with orientation notes.

  • Wind speed estimation from damage is approximate; use a damage indicator scale (such as a roof-covering damage scale) alongside weather data rather than relying on visual estimates alone.