HK Engine Operator Grade 2 flashcards
HK Engine Operator Grade 2 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Watch handover briefing
- The relieving engineer receives a face-to-face report on machinery status, active alarms, fuel and water levels, ongoing work, and standing orders, then signs the logbook to accept responsibility.
- Exhaust temperature spread
- The difference in exhaust gas temperature between cylinders. A spread beyond roughly 30-50 C indicates a faulty injector, valve, or fuel rack setting on the affected unit.
- Bell book function
- A record of every engine telegraph order with its time and the engine response. Each order is repeated back to the bridge before execution during manoeuvring.
- Standby engine preparation
- Before arrival: pre-lubricate, warm fuel to correct viscosity, test telegraph and alarms, drain air bottle condensate, and confirm steering gear and generator readiness.
- Cylinder liner wear rate
- A normal wear rate is about 0.05-0.1 mm per 1000 running hours. A sudden increase suggests abrasion, poor combustion, or inadequate cylinder lubrication.
- Starting air pressure minimum
- Manoeuvring requires sufficient starting air, typically above 2.0-2.5 MPa, with compressors maintaining receiver pressure. Low air pressure prevents reliable engine starting.
- Unattended machinery space
- A space where alarms and safety systems allow operation without a permanent watch. The system must not be isolated while the engine is manoeuvring.
- Four-stroke cycle
- Intake, compression, power, and exhaust strokes complete in two crankshaft revolutions, giving one power stroke per cylinder per two revolutions.
- Two-stroke cycle
- Scavenging and compression occur together, with one power stroke per crankshaft revolution. Air is supplied by a blower or turbocharger through scavenge ports.
- Fuel oil viscosity control
- Fuel is heated to the injector specification, often 10-15 cSt at injection. Too viscous causes poor atomisation; too hot causes pump wear and leakage.
- Purifier gravity disc
- The disc bore is selected to match fuel density and sets the water-oil interface. An oversized bore allows water to escape with the clean oil outlet.
- Total base number
- TBN measures a lube oil's capacity to neutralise acids from combustion. Falling TBN shows the additive is being consumed and the oil may need renewal.
- Turbocharger surging
- Repeated whooshing with rpm fluctuation, caused by fouled blades, a blocked charge air cooler, or rapid load change. It can damage bearings if allowed to continue.
- Air distributor function
- Times pilot air to each cylinder head starting valve in the correct firing order, so the engine cranks in sequence during starting.
- Jacket water circuit
- Freshwater cooling loop serving cylinder liners and heads, kept hot to limit thermal stress, with heat rejected through a central cooler to seawater.
- Bilge mud box
- A strainer box on the bilge suction line that traps debris before the pump. It must be cleaned regularly to prevent blockage and loss of bilge suction.
- 15 ppm bilge alarm
- Monitors oily water separator output. If oil content exceeds 15 ppm the alarm activates and discharge stops automatically, as required by MARPOL Annex I.
- Fuel quick-closing valve
- A remotely operated valve on the fuel tank outlet, closed from outside the engine room in an emergency to cut fuel supply and limit a fire.
- Engine room fire response
- Raise the alarm, stop fuel and ventilation, close quick-closing valves, then release fixed CO2 or foam. Do not open the space until it has cooled.
- Enclosed space entry
- Requires a permit, atmosphere testing for oxygen, hydrocarbons, and toxic gases, a standby person at the entrance, and rescue equipment ready for immediate use.
- Emergency generator test
- Must start automatically on main power failure and accept load within the class time, commonly 45 seconds. It is tested weekly under load.
- MARPOL Annex V garbage
- Plastics are never discharged overboard. Other garbage discharge depends on category and distance from land, and every discharge is recorded in the Garbage Record Book.
- MARPOL Annex IV sewage
- Discharge is allowed with an approved treatment plant, or beyond 12 nautical miles from land when comminuted and disinfected using approved equipment.
- Hot work permit
- Required before welding or burning. It specifies fire watch, removal of combustibles, ventilation, and gas testing, and is signed by the responsible officer.
- Local vessel ordinance
- Hong Kong's Merchant Shipping (Local Vessels) Ordinance and regulations govern certification, operation, and safety of local vessels, including engine operator qualifications.
- Oil record book retention
- Local vessels must keep oil record book entries and engine room logs available for Marine Department inspection on request, showing bunkering and discharge records.
- Port reception facilities
- Shore facilities that receive oily waste, sewage, and garbage. Vessels must use them instead of discharging into Hong Kong waters and retain receipts.
- Typhoon Signal No. 3
- Strong wind signal. Vessels secure moorings and prepare machinery for possible worsening conditions while maintaining a listening watch on broadcasts.
- Typhoon Signal No. 8
- Gale or storm signal. Vessels move to designated typhoon shelters, secure moorings, and keep engines ready for immediate manoeuvring if needed.
- Vessel Traffic Centre
- Hong Kong Marine Department facility issuing harbour directions and traffic information. Vessels must comply with its instructions in harbour waters.
- Machinery defect reporting
- Any defect affecting seaworthiness or manoeuvrability must be reported to the Marine Department, which may require the vessel to stay in port.
- Muster list familiarity
- Crew must know their emergency stations and the location of firefighting and lifesaving appliances before the vessel sails, as shown on the posted muster list.