HKIE Professional Assessment - Mechanical Discipline study materials
HKIE Professional Assessment - Mechanical Discipline study resources

HKIE Professional Assessment - Mechanical Discipline cheat sheet

HKIE Professional Assessment - Mechanical Discipline · Keep the key ideas within reach.

Quick reference

Mechanical Engineering Science and Analysis

  • Steady-flow energy equation: q − w = Δh + ΔKE + ΔPE; for adiabatic nozzle/ diffuser w = 0 and h₁ + V₁²/2 = h₂ + V₂²/2.

  • Carnot efficiency η = 1 − T_L/T_H with absolute temperatures; no real cycle between the same reservoirs can exceed it.

  • Reynolds number Re = ρVD/μ = VD/ν; pipe flow is laminar below about 2,000 and fully turbulent above about 4,000 in circular pipes.

  • Darcy–Weisbach head loss h_f = f(L/D)(V²/2g); friction factor f from Moody chart using relative roughness ε/D and Re.

  • Bernoulli with losses: p₁/γ + V₁²/2g + z₁ = p₂/γ + V₂²/2g + z₂ + h_L; pump head added on the left side.

  • Bending stress σ = My/I; maximum at extreme fibre y = c; section modulus Z = I/c gives σ = M/Z.

  • Euler buckling load P_cr = π²EI/(KL)²; effective length factor K depends on end restraint (K = 1 pinned–pinned, 0.5 fixed–fixed, 2 fixed–free).

  • Single-degree-of-freedom vibration: natural frequency ω_n = √(k/m), damping ratio ζ = c/(2√(km)), resonance near ω/ω_n = 1.

Quick reference

Design, Specification and Material Selection

  • Design factor (safety factor) = failure strength / allowable stress; applied to yield for ductile members and to ultimate for brittle members.

  • Ashby material index method: express objective (mass, stiffness, strength) as a function of material properties, then select the material maximising or minimising that index.

  • Stiffness-limited light beam index E^(1/2)/ρ for a bending beam of fixed length and stiffness; strength-limited index σ_y^(2/3)/ρ.

  • Ductile-to-brittle transition: carbon steels show a Charpy transition temperature; specify steel with transition temperature below the minimum service temperature.

  • Galvanic corrosion risk rises with the potential difference between dissimilar metals; avoid coupling stainless steel to aluminium in wet environments or insulate the joint.

  • Tolerance stack-up: worst-case arithmetic sum of tolerances versus statistical (root-sum-square) method; specify fits per ISO 286 hole-basis or shaft-basis systems.

  • Weld symbols follow ISO 2553; a fillet weld leg length and throat thickness relate by throat = 0.707 × leg.

  • Pressure vessel design to BS EN 13445 or ASME VIII uses minimum thickness t = pD/(2SE − p) plus corrosion allowance for cylindrical shells.

Quick reference

Manufacturing, Installation, Commissioning and Maintenance

  • Fit-up and alignment tolerances for rotating machinery are checked with dial gauges or laser alignment; allowable shaft offset and angularity are typically below 0.05 mm for high-speed sets.

  • Commissioning sequence: static checks, pressure/leak testing, flushing, no-load run, load test, performance verification, then handover with as-built records.

  • Hydrostatic test pressure for pipework is commonly 1.5 times design pressure (or per the applicable code), held for a defined duration with no pressure loss.

  • Preventive maintenance intervals derive from manufacturer data, failure history and criticality; condition monitoring (vibration, thermography, oil analysis) drives predictive maintenance.

  • Vibration severity for rotating machines is judged against ISO 10816/20816 zone boundaries (A/B/C/D) measured as RMS velocity in mm/s.

  • Non-destructive testing methods: dye penetrant (surface-breaking defects), magnetic particle (ferromagnetic surface/near-surface), ultrasonic (internal), radiography (internal volumetric).

  • Balancing grades follow ISO 1940-1; permissible residual unbalance e_per × rotor mass per balance quality grade G.

  • Factory acceptance test (FAT) and site acceptance test (SAT) are separate gates; FAT results do not replace site commissioning verification.

Quick reference

Building Services and Environmental Control Engineering

  • Sensible heat gain Q_s = 1.23 × airflow (L/s) × ΔT (°C) for air at standard conditions; latent heat uses moisture content difference.

  • Cooling coil apparatus dew point and bypass factor determine supply air condition; room load ratio fixes the supply air temperature difference.

  • Fan and pump laws: flow ∝ speed, head ∝ speed², power ∝ speed³; affinity laws underpin variable-speed control savings.

  • Coefficient of performance COP = cooling output / electrical input; chiller efficiency in kW/tonne or COP, with IPLV for part-load performance.

  • Hong Kong energy code (Building (Energy Efficiency) Regulation and BEC) sets maximum allowable power densities and requires energy audits for prescribed buildings.

  • Fire services installations in Hong Kong are governed by the Fire Services Department Circular Letters and Codes of Practice for minimum fire service installations and equipment.

  • Plumbing and drainage design follows the Water Supplies Department requirements and the Building (Plumbing) Regulations; soil and waste stacks require venting to protect trap seals.

  • Smoke control: pressurised staircases and smoke extraction systems are designed to maintain tenability; fan sizing must account for leakage through closed doors.

Quick reference

Codes, Standards and Statutory Requirements in Hong Kong

  • Buildings Ordinance (Cap. 123) and its subsidiary regulations govern building works; Buildings Department codes of practice give deemed-to-satisfy design rules.

  • Builders' lift and escalator installations are regulated under the Lifts and Escalators Ordinance (Cap. 618), with registration of contractors and periodic examination.

  • Pressure equipment and gas installations fall under the Gas Safety Ordinance (Cap. 51) and related regulations; registered gas contractors must carry out installation work.

  • The Factories and Industrial Undertakings Ordinance (Cap. 59) and subsidiary regulations (including safety management) set duties on contractors and employers.

  • Registration of engineers is under the Engineers Registration Ordinance (Cap. 409); the HKIE assesses professional competence for corporate membership and the professional assessment.

  • Fire safety in buildings is covered by the Code of Practice for Fire Safety in Buildings, covering means of escape, fire resisting construction and access for firefighting.

  • Occupational safety legislation requires risk assessments, safe systems of work and reporting of accidents to the Labour Department under the relevant regulations.

  • Statutory submissions for building services works require coordination with Buildings Department, Fire Services Department and Water Supplies Department approvals.

Quick reference

Health, Safety and Environmental Management

  • Risk assessment hierarchy of control: eliminate, substitute, engineering controls, administrative controls, then personal protective equipment as last resort.

  • Risk score = likelihood × severity; ALARP principle requires reducing risk so far as is reasonably practicable.

  • Confined space entry requires a permit, atmospheric testing for oxygen (19.5–23.5%), flammable gas and toxic gas, plus rescue arrangements and standby person.

  • Incident investigation models: Swiss cheese (Reason) model and 5-why / root cause analysis; findings should address system failures, not only individual error.

  • Lifting operations require a lifting plan, competent person, certified lifting gear and exclusion zones; SWL must not be exceeded.

  • Environmental impact assessment under the Environmental Impact Assessment Ordinance (Cap. 499) requires a permit for designated projects.

  • Noise control under the Noise Control Ordinance (Cap. 400) covers construction noise permits, restricted hours and prescribed noise standards.

  • Waste management follows the Waste Disposal Ordinance (Cap. 354); construction and demolition waste should be reduced, reused and recycled before disposal.

Quick reference

Project and Engineering Management

  • Critical path method: float = late start − early start; activities on the critical path have zero total float and drive project duration.

  • Earned value: CV = EV − AC, SV = EV − PV, CPI = EV/AC, SPI = EV/PV; CPI below 1 indicates cost overrun.

  • Standard contract forms in Hong Kong include the HKIA/HKIS Standard Form of Building Contract and the Government General Conditions of Contract; risk allocation differs between them.

  • Variation valuation follows the contract's rates and prices; where no rate applies, a fair valuation based on reasonable cost plus profit is used.

  • Quality assurance uses the plan–do–check–act cycle; inspection and test plans (ITP) define hold points and witness points for verification.

  • Stakeholder communication plan records audience, message, channel, frequency and owner; reporting lines must match the project organisation structure.

  • Liquidated damages must be a genuine pre-estimate of loss, not a penalty, to be enforceable.

  • Programme float ownership and extension of time entitlement depend on the contract; concurrent delay treatment should be stated in the contract.

Quick reference

Professional Ethics, Sustainability and the Engineer's Role in Society

  • Core ethical duties: competence, honesty, public safety and health first, confidentiality, avoidance of conflicts of interest, and fair dealing.

  • Whistleblowing duty: where a serious risk to public safety exists, the engineer should escalate internally and, if unresolved, to the appropriate authority.

  • Sustainable design applies life-cycle assessment; embodied carbon plus operational carbon gives whole-life carbon for a system.

  • Energy efficiency hierarchy: reduce demand, improve conversion efficiency, recover waste energy, then use low-carbon supply.

  • Declaring conflicts of interest in writing and withdrawing from decisions where impartiality is compromised is a standard professional requirement.

  • Continuing professional development (CPD) is expected of registered engineers to maintain competence in a changing technical and regulatory environment.

  • Signing and certifying work implies personal responsibility for its technical adequacy; only sign within your own competence.

  • Environmental and social impacts should be considered at concept stage, when the greatest opportunity to influence whole-life performance exists.