Diagnostic Radiographer · Keep the key ideas within reach.

Quick reference

Radiation Protection and Radiobiology

  • ALARA: occupational dose limit 20 mSv/year averaged over 5 years (100 mSv per 5 years), with no single year exceeding 50 mSv.

  • Public dose limit: 1 mSv/year effective dose; lens of eye equivalent dose limit 15 mSv/year for workers (ICRP 2011).

  • Effective dose E = Σ w_T · H_T, where w_T is tissue weighting factor and H_T is equivalent dose; H_T = w_R · D_T.

  • Radiation weighting factors w_R: photons and electrons = 1; protons = 2; alpha particles = 20; neutrons = 2.5–20 depending on energy.

  • Linear energy transfer (LET) is the energy deposited per unit path length; high-LET radiation (alpha, neutrons) has greater relative biological effectiveness (RBE) and higher oxygen enhancement ratio.

  • Law of Bergonié and Tribondeau: cells are most radiosensitive when undifferentiated, rapidly dividing, and have a long mitotic future (e.g., basal cells, lymphocytes, intestinal crypt cells).

  • Acute radiation syndrome thresholds: prodromal syndrome ~1 Gy, hematopoietic syndrome ~2–5 Gy, gastrointestinal syndrome ~5–12 Gy, cerebrovascular syndrome >20 Gy.

  • Inverse square law: intensity I₁/I₂ = (d₂/d₁)²; doubling distance from a point source reduces exposure to one quarter.

  • Half-value layer (HVL): thickness of material that reduces beam intensity to 50%; for diagnostic X-rays, typical HVL is 2.5–4 mm Al at 70–80 kVp.

Quick reference

Equipment Operation and Quality Control

  • X-ray tube cathode: tungsten filament thermionic emission; anode: tungsten-rhenium target with focal spot sizes; stationary anode for low-power, rotating anode for high-power applications.

  • Heel effect: X-ray intensity is lower on the anode side of the beam; place thicker body parts toward the cathode side to compensate.

  • Automatic exposure control (AEC) uses ionization chambers or solid-state detectors to terminate exposure when a preset receptor dose is reached; density controls adjust the reference signal.

  • Quality control tests: kVp accuracy ±5% or ±5 kVp; timer accuracy ±5% for times >10 ms; mAs linearity ±10%; exposure reproducibility ±5%; HVL within manufacturer specification.

  • Collimator alignment: X-ray field must coincide with light field to within 2% of source-to-image distance (SID) on each side.

  • Focal spot size measured by pinhole camera or star pattern; nominal focal spot sizes 0.6 mm and 1.2 mm common; small focal spot improves spatial resolution.

  • Digital detector calibration: flat-field (gain) calibration corrects for detector nonuniformity; bad pixel maps are generated during QC.

  • Processor QC: sensitometry for film processors measures speed, contrast, and base-plus-fog; base-plus-fog should not exceed 0.20 optical density.

Quick reference

Image Production and Evaluation

  • Photoelectric effect dominates at low kVp (below ~50 keV) and in high-Z materials; it provides high subject contrast but increases patient dose.

  • Compton scatter dominates at higher kVp and in low-Z materials (soft tissue); scatter reduces contrast and increases fog.

  • Beam attenuation: I = I₀ e^(−μx), where μ is linear attenuation coefficient and x is thickness; half-value layer HVL = 0.693/μ.

  • Spatial resolution is limited by focal spot size, detector element (del) size, and motion; modulation transfer function (MTF) quantifies resolution performance.

  • Contrast resolution (low-contrast detectability) depends on noise, which is inversely proportional to the square root of the number of photons (quantum mottle).

  • Grid ratio = height of lead strips / distance between strips; higher grid ratio removes more scatter but requires higher mAs and precise centering.

  • Grid cutoff occurs when the central ray is not perpendicular to the grid or when the grid is used outside its focal range; it appears as a uniform or bilateral density loss.

  • Deviation index (DI) = actual exposure index (EI) − target EI; DI within ±3 is generally acceptable, indicating exposure within ~30% of optimal.

Quick reference

Radiographic Procedures and Positioning

  • AP projection: central ray enters anterior and exits posterior; PA projection: enters posterior and exits anterior; lateral: enters side and exits opposite side.

  • Oblique positions are named by the side closest to the image receptor (e.g., RAO = right anterior oblique).

  • Chest radiography: PA erect at 180 cm (72 in) SID, 110–125 kVp, high mA with short exposure time; lateral at 180 cm with arms elevated.

  • Abdomen: supine AP (KUB) at 100 cm SID, 70–80 kVp; upright abdomen to demonstrate air-fluid levels and free air.

  • Cervical spine lateral: 180 cm SID, patient upright, chin slightly elevated; ensure all seven cervical vertebrae and C7-T1 junction are visible.

  • Lumbar spine AP: 100 cm SID, 75–85 kVp; lateral: 100 cm SID, patient in lateral recumbent or standing position with knees flexed.

  • Skull: PA (Caldwell) at 100 cm SID with 15° caudal tube angle; lateral at 100 cm SID with interpupillary line perpendicular to IR.

  • Extremity radiography: SID 100 cm; use small focal spot; collimate to include joint above and below the area of interest.

Quick reference

Patient Care and Management

  • Informed consent must include the nature of the procedure, risks, benefits, alternatives, and the patient's right to refuse.

  • Universal precautions: treat all blood and body fluids as potentially infectious; use gloves, gown, mask, and eye protection as indicated.

  • Contrast media reactions: mild (nausea, flushing, urticaria) managed supportively; moderate (vomiting, bronchospasm) require antihistamines and monitoring; severe (anaphylaxis, laryngeal edema) require epinephrine and emergency response.

  • Metformin and iodinated contrast: withhold metformin for 48 hours after contrast in patients with renal impairment or at risk of lactic acidosis.

  • Pregnancy screening: ask all patients of childbearing age about last menstrual period and possibility of pregnancy; use lead shielding and optimize exposure.

  • Patient identification: use at least two identifiers (name and date of birth or medical record number) before every procedure.

  • Immobilization devices: sandbags, sponges, and tape reduce motion; use for pediatric and uncooperative patients.

  • Vital signs: normal adult heart rate 60–100 bpm, respiratory rate 12–20/min, blood pressure <120/80 mmHg, temperature 36.5–37.5°C.

Quick reference

Anatomy and Physiology / Cross-Sectional Anatomy

  • Standard anatomical position: body erect, face forward, arms at sides with palms forward, feet parallel.

  • Anatomical planes: sagittal (divides left and right), coronal (divides anterior and posterior), transverse/axial (divides superior and inferior).

  • Body cavities: thoracic (heart, lungs, mediastinum), abdominal (liver, spleen, kidneys, intestines), pelvic (bladder, reproductive organs, rectum).

  • Vertebral column regions: cervical (7), thoracic (12), lumbar (5), sacral (5 fused), coccygeal (3–4 fused); total 33 vertebrae in adults.

  • Liver occupies right upper quadrant, extends across midline; spleen lies in left upper quadrant posterior to stomach.

  • Kidneys are retroperitoneal at T12–L3 level; right kidney slightly lower due to liver.

  • Cross-sectional CT: Hounsfield units (HU) = 1000 × (μ_tissue − μ_water) / μ_water; water = 0 HU, air = −1000 HU, bone = +1000 HU or higher.

  • Chest CT: mediastinal window (W ~350, L ~50 HU) for soft tissue; lung window (W ~1500, L ~−600 HU) for parenchyma.

Quick reference

Radiologic Physics

  • X-ray production: bremsstrahlung (continuous spectrum from electron deceleration) and characteristic X-rays (discrete energies from electron shell transitions).

  • Maximum X-ray energy (keV) equals the kVp applied across the tube; the continuous spectrum has a maximum at approximately one-third to one-half of kVp.

  • mAs controls the quantity of X-rays (exposure); kVp controls the quality (penetrating power) and also affects quantity approximately as kVp².

  • Filtration: inherent filtration (glass envelope, oil) equivalent to ~0.5–1.0 mm Al; added filtration brings total to at least 2.5 mm Al for tubes operating above 70 kVp.

  • Half-life of common radionuclides: Tc-99m 6 hours, I-131 8 days, F-18 110 minutes, Mo-99 66 hours.

  • Radioactive decay: N = N₀ e^(−λt); activity A = λN; half-life T½ = 0.693/λ.

  • Electromagnetic spectrum: X-rays have wavelengths 0.01–10 nm and frequencies 3×10^16–3×10^19 Hz; they travel at the speed of light in a vacuum.

  • Photoelectric absorption cross-section increases with atomic number (Z³) and decreases with photon energy (1/E³).

Quick reference

Professionalism, Ethics, and Regulatory Compliance

  • ARRT Standards of Ethics: Code of Ethics (aspirational) and Rules of Ethics (enforceable); violations may result in sanctions, suspension, or revocation of certification.

  • Patient confidentiality: HIPAA Privacy Rule protects individually identifiable health information; minimum necessary standard applies to disclosures.

  • Informed consent is required for invasive procedures and research; documentation must be in the patient's record.

  • Scope of practice: radiographers must perform only procedures for which they are educationally prepared and legally authorized; state licensure may add requirements.

  • Radiation protection regulations: 10 CFR Part 20 (occupational dose limits), 21 CFR Part 1020 (performance standards for diagnostic X-ray systems), and state radiation control programs.

  • Continuing education: ARRT requires 24 credits every 2 years, including at least 12 in the discipline of certification and 1 credit in ethics.

  • Medical error reporting: report errors and near misses through institutional incident reporting systems; disclosure to patients is an ethical obligation.

  • Professional boundaries: avoid dual relationships, maintain patient dignity, and obtain consent before any physical contact or exposure.