IA Water Operator flashcards
IA Water Operator · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- Product of disinfectant residual concentration (mg/L) and contact time (minutes). Used to determine log inactivation credit for pathogens; required CT varies with disinfectant, temperature, and pH.
- Log inactivation
- A 1-log reduction removes 90% of pathogens; 2-log removes 99%; 3-log removes 99.9%; 4-log removes 99.99%. Used to express treatment credit under the Surface Water Treatment Rule.
- Jar test
- Bench-scale simulation of coagulation, flocculation, and sedimentation. Used to determine optimal coagulant dose, pH, and mixing conditions before full-scale application.
- Filter loading rate
- Flow rate divided by filter surface area, typically expressed in gpm/ft². Rapid sand filters commonly operate at 2–5 gpm/ft²; exceeding design rate may cause turbidity breakthrough.
- Chlorine demand
- The difference between the chlorine dose applied and the free chlorine residual remaining after a specified contact time. Demand must be satisfied before a persistent residual can be measured.
- Turbidity limit
- Under conventional filtration, finished water turbidity must be ≤0.3 NTU in at least 95% of monthly measurements and must never exceed 1 NTU. Measured in NTU by nephelometry.
- Distribution residual minimum
- A detectable disinfectant residual must be maintained throughout the distribution system. Typical minimums are 0.2 mg/L free chlorine or 0.5 mg/L chloramine at all sampling points.
- Water hammer
- Pressure surge caused by sudden changes in flow velocity, such as rapid valve closure or pump trip. Prevented by slow valve operation, surge tanks, air valves, and proper pump sequencing.
- Cross-connection control
- Prevention of backflow between potable and non-potable systems. An air gap provides absolute protection; reduced-pressure zone and pressure vacuum breaker devices are testable mechanical alternatives.
- Hazen-Williams formula
- Head loss equation: hf = 4.52 × Q^1.852 × C^-1.852 × d^-4.87, where Q is flow in cfs, d is pipe diameter in ft, and C is the roughness coefficient. Used for distribution main design.
- Storage tank turnover
- The time required to cycle the volume of a distribution storage tank. Maintaining 3–5 day turnover prevents stagnation, disinfectant decay, and water quality degradation.
- Specific capacity
- Pumping rate divided by drawdown, expressed in gpm per foot. Indicates well efficiency; declining specific capacity may signal clogging, pump wear, or aquifer depletion.
- GWUDI
- Groundwater under the direct influence of surface water. Determined by hydrogeologic and water quality analysis; if designated, the source must receive surface water treatment including filtration and disinfection.
- Cone of depression
- The drawdown shape formed around a pumping well. Its radius and depth depend on pumping rate, aquifer transmissivity, and storativity; overlapping cones indicate well interference.
- Saltwater intrusion
- Movement of saline water into freshwater aquifers when pumping lowers the freshwater head below the seawater interface. Managed by reducing pumping, relocating wells, or artificial recharge.
- TMDL
- Total maximum daily load: the maximum amount of a pollutant a waterbody can receive and still meet water quality standards. Used in source water protection and watershed planning.
- MCL vs MCLG
- MCL is an enforceable maximum contaminant level set as close to the MCLG as feasible. MCLG is a non-enforceable health-based goal with no known or anticipated health risk.
- Total coliform rule
- Requires routine coliform monitoring. For systems collecting more than 40 samples per month, no more than 5% may be positive. Any E. coli positive is a violation.
- Stage 2 DBPR limits
- Sets MCLs for total trihalomethanes at 80 µg/L and five haloacetic acids at 60 µg/L, calculated as a locational running annual average at each monitoring site.
- Lead and copper action levels
- Action level for lead is 0.015 mg/L and for copper is 1.3 mg/L, based on the 90th percentile of samples. Exceeding triggers corrosion control treatment and public education.
- Consumer Confidence Report
- Annual water quality report delivered to customers by July 1. Must include source water information, detected contaminants, health effects, and educational statements required by regulation.
- Public notification tiers
- Tier 1 requires immediate notice within 24 hours for acute violations. Tier 2 requires notice within 30 days; Tier 3 requires annual notice for less urgent violations.
- Confined space atmosphere
- Before entry, test for oxygen (acceptable 19.5–23.5%), flammable gases (below 10% LEL), and toxic gases. A permit and attendant are required for permit-required confined spaces.
- Chlorine gas IDLH
- Immediately dangerous to life or health concentration for chlorine is 10 ppm. Response requires supplied-air respiratory protection and upwind evacuation; air-purifying respirators are inadequate.
- Lockout/tagout
- Hazardous energy control procedure: isolate energy sources, apply locks and tags, and verify zero energy before maintenance. Prevents unexpected startup or release of stored energy.
- Trench protective systems
- Excavations 5 ft or deeper require shoring, sloping, or shielding. Spoil piles must be at least 2 ft from the edge; access ladders within 25 ft of workers.
- Eyewash and shower
- Emergency eyewash and safety shower must be within 10 seconds travel distance of chemical hazards and flush for at least 15 minutes. Weekly activation verification is recommended.
- GFCI protection
- Ground-fault circuit interrupter protection is required for portable electrical tools used in wet or damp locations. It interrupts power when a ground fault is detected to prevent shock.
- DPD free chlorine method
- Colorimetric method using DPD indicator; free chlorine reacts to form a magenta color read at 515 nm. Monochloramine interference is addressed by differentiated procedures.
- Turbidity measurement
- Nephelometric method measures light scattered by suspended particles, reported in NTU. Calibrate with primary standards such as formazin and verify with secondary standards.
- Heterotrophic plate count
- Pour plate method incubating at 35°C for 48 hours; results reported as CFU/mL. Indicates general bacterial population and treatment effectiveness, not a regulatory MCL.
- Chain of custody
- Documentation tracking sample possession from collection through analysis. Includes sample ID, date/time, collector, preservation, and requested analyses; ensures legal defensibility of results.
- Laboratory quality control
- Each analytical batch includes a method blank, duplicate, and matrix spike. Duplicate relative percent difference typically must be ≤20% to accept results.