IAI CLPE study materials
IAI CLPE study resources

IAI CLPE cheat sheet

IAI CLPE · Keep the key ideas within reach.

Quick reference

Latent Print Identification

  • ACE-V is the documented comparison method: Analysis, Comparison, Evaluation, Verification; each stage is recorded before the next begins.

  • Analysis establishes the features of the latent (clarity, distortion, matrix, substrate, development technique) and the features of the known print independently.

  • Comparison is a side-by-side assessment of corresponding features in sequence, not a global visual impression; the examiner documents what was compared.

  • Evaluation yields one of three conclusions: identification (individualization), exclusion, or inconclusive; no probability or 'possible match' conclusion is permitted.

  • Individualization requires sufficient quantity and quality of corresponding ridge features in agreement, with no unexplained dissimilarities.

  • Level 1 detail = ridge flow and pattern type; Level 2 = ridge path, bifurcations, endings, and their spatial relationships; Level 3 = pores, edge shape, and ridge width.

  • Verification is an independent re-examination by another qualified examiner who reaches the same conclusion; it is not a review of the first examiner's notes for agreement.

  • Exclusion requires an area of the latent that is clear and undistorted enough to show a true discrepancy in ridge path or feature relationship.

  • Inconclusive applies when the latent lacks sufficient quality or quantity for either identification or exclusion; it is a valid, reportable outcome.

Quick reference

Latent Print Development

  • Development sequence for porous items: visual examination, then amino acid reagents (ninhydrin, DFO, 1,2-indanedione), then physical developers (PD, oil red O) for lipids.

  • Ninhydrin reacts with amino acids and is developed with heat and humidity (roughly 80 °C and 65% RH); it yields Ruhemann's purple and can overdevelop.

  • DFO and 1,2-indanedione are fluorogenic amino acid reagents read under laser/ALS with filters; 1,2-indanedione generally gives stronger luminescence than DFO.

  • Physical developer works on porous surfaces after amino acid reagents and detects lipid/water-insoluble components; it is incompatible with prior wetting by aqueous reagents.

  • Cyanoacrylate fuming polymerizes on non-porous surfaces; acceleration is achieved with heat and controlled humidity (around 80% RH); dye staining (rhodamine, basic yellow 40) follows.

  • Powder application suits non-porous, dry surfaces; powder choice depends on substrate color and texture; magnetic powders are used on smooth or flexible surfaces.

  • Iodine fuming is a reversible, temporary visualization best used on porous or thermal paper and must be photographed or fixed immediately.

  • Silver nitrate reacts with chloride (salt) deposits and is used on porous items such as wood and paper; it is typically applied after ninhydrin.

  • Sequencing matters: a reagent used out of order can destroy or mask later development; document each step and any negative result.

Quick reference

Overall Policies and Procedures

  • Chain of custody records every transfer of evidence: who, what, when, and where; gaps are documented and explained, not omitted.

  • Evidence packaging must prevent contamination and loss: porous items in paper, non-porous in paper or breathable containers; never seal damp items in plastic.

  • Quality assurance includes proficiency testing, case review, and documented corrective action when errors are found.

  • Examiners must disclose conflicts of interest, prior involvement, and any limitation on the examination in the report.

  • Reports state the conclusion, the basis (features compared), and any limitations; they avoid statistical probability language for individualization.

  • Testimony is limited to the examiner's own analysis and the discipline's accepted methodology; the examiner does not opine beyond the scope of the examination.

  • Laboratory accreditation (e.g., ISO/IEC 17025) and certification (e.g., IAI certification) are separate: accreditation applies to the lab, certification to the individual.

  • Documentation must be sufficient for an independent examiner to reconstruct the analysis without the original examiner's presence.

  • Bias mitigation includes linear sequential unmasking: the examiner analyzes the latent before seeing the known print, and any exposure is documented.