IAPMO UPC PI study materials
IAPMO UPC PI study resources

IAPMO UPC PI key terms

IAPMO UPC PI · Get comfortable with the vocabulary.

Authority Having Jurisdiction (AHJ)

The organization, office, or individual responsible for enforcing the code, interpreting its provisions, and approving materials, equipment, and installations. Inspectors and plan reviewers act as the AHJ's representatives.

Related: Permit, Plan Review
Permit

A written authorization issued by the AHJ allowing work described in an application. Work may not begin until the permit is issued, and the permit lapses if work is not started or inspected within the time the code sets.

Related: Authority Having Jurisdiction (AHJ), Rough-In Inspection
Plan Review

The AHJ's pre-construction examination of submitted drawings and specifications to verify code compliance before a permit is issued. Reviewers check fixture counts, pipe sizing, venting, and gas load calculations against the code.

Related: Permit, Fixture Unit
Rough-In Inspection

An inspection performed after piping is installed but before it is covered, concealed, or permanently connected, allowing the inspector to verify sizing, slope, support, and venting while the work is still visible.

Related: Final Inspection, Hydrostatic Test
Final Inspection

The closing inspection conducted when the work is complete, confirming that fixtures, appurtenances, and connections are installed, tested, and functioning as approved before the system is placed in service.

Related: Rough-In Inspection, Backflow Preventer
Hydrostatic Test

A pressure test of a drainage or water supply system performed by filling it with water and observing it for a set period. Leaks, drops in pressure, or visible seepage indicate failure.

Related: Air Test, Rough-In Inspection
Air Test

A test in which a drainage system is sealed and pressurized with air to a specified pressure and monitored for leakage. It is an alternative to water testing where freezing, weight, or site conditions make hydrostatic testing impractical.

Related: Hydrostatic Test, Stack
Trap Seal

The depth of water held in a trap's dip that blocks sewer gas from entering a building. The code sets a required depth, and the seal is lost by evaporation, siphonage, backpressure, or capillary action.

Related: Trap Arm, Vent, Air Gap
Trap Arm

The pipe segment between a fixture trap and the point where it connects to a branch or stack. Its length and fall are limited by the code so the trap seal is not self-siphoned.

Related: Trap Seal, Fixture Branch, Vent
Vent

A pipe or opening that admits air into a drainage system to protect trap seals from siphonage and backpressure and to allow sewer gases to escape outdoors above the roof.

Related: Vent Stack, Trap Seal, Air Admittance Valve
Vent Stack

A vertical vent pipe that extends through the roof and serves one or more drainage stacks, providing relief air to the drainage system. It must terminate at the required height above roof and openings.

Related: Vent, Stack, Vent Terminal
Stack

A general term for a main vertical pipe in a drainage or venting system. A soil stack carries fixtures with solids; a waste stack carries fixtures without solids; a vent stack carries air.

Related: Vent Stack, Building Drain, Stack Vent
Building Drain

The lowest piping inside a building that receives the discharge of soil, waste, and other drainage pipes and conveys it to the building sewer. It is typically sized and sloped for gravity flow.

Related: Building Sewer, Stack, Cleanout
Building Sewer

The pipe conveying sewage from the building drain to the public sewer or private disposal system. It begins outside the building foundation wall and is often governed by separate requirements from the building drain.

Related: Building Drain, Sewer Lateral
Cleanout

An accessible fitting with a removable plug or cap that allows a drain or sewer to be rodded or cleared of blockages. The code prescribes where cleanouts are required and how they must be accessible.

Related: Building Drain, Trap Arm
Fixture Unit

A dimensionless measure of the probable drainage load or water supply demand of a plumbing fixture, used to size pipes and vents. One fixture unit approximates the load of a lavatory.

Related: Drainage Fixture Unit, Water Supply Fixture Unit, Plan Review
Drainage Fixture Unit (DFU)

The fixture-unit value assigned to a fixture based on its discharge rate and characteristics, used to size drainage pipes, branches, and stacks in accordance with code tables.

Related: Fixture Unit, Water Supply Fixture Unit, Building Drain
Water Supply Fixture Unit (WSFU)

The fixture-unit value reflecting a fixture's probable hot and cold water demand, used to size water distribution piping and the water service. Values differ for cold, hot, and total demand.

Related: Fixture Unit, Drainage Fixture Unit (DFU), Water Service
Water Service

The pipe and fittings that convey potable water from the public main or private source to the building, ending at the point where the building's water distribution system begins.

Related: Water Distribution Pipe, Backflow Preventer, Water Supply Fixture Unit (WSFU)
Water Distribution Pipe

Piping within a building that conveys potable water from the service to fixtures and appliances. Sizing depends on fixture-unit demand, developed length, pressure, and allowable friction loss.

Related: Water Service, Pressure-Reducing Valve, Water Hammer Arrestor
Pressure-Reducing Valve

A device installed in a water supply line to lower incoming pressure to a safe, usable level for the building's piping and fixtures. It is required where supply pressure exceeds the code limit.

Related: Water Distribution Pipe, Thermal Expansion, Water Hammer Arrestor
Backflow Preventer

An assembly or device that prevents reverse flow of contaminated water into the potable supply. Selection depends on the degree of hazard and must match the assembly type approved for that hazard.

Related: Air Gap, Cross-Connection, Vacuum Breaker
Cross-Connection

Any actual or potential link between the potable water supply and a source of contamination or pollution. Cross-connections must be eliminated or protected by an approved backflow prevention method.

Related: Backflow Preventer, Air Gap, Vacuum Breaker
Air Gap

An unobstructed vertical separation between a water supply outlet and the flood-level rim of a receiving vessel. It is the most reliable form of backflow protection because it relies on no moving parts.

Related: Backflow Preventer, Cross-Connection, Trap Seal
Vacuum Breaker

A device that admits air into piping to break a vacuum and prevent backsiphonage. Atmospheric and pressure-type versions are applied to specific fixtures and must be installed in the orientation the listing requires.

Related: Backflow Preventer, Cross-Connection, Air Gap
Water Hammer Arrestor

A device containing a trapped air chamber or piston that absorbs the pressure surge created when a valve closes quickly, protecting piping and fixtures from noise and damage.

Related: Water Distribution Pipe, Pressure-Reducing Valve
Thermal Expansion

The increase in water volume as it is heated, which raises pressure in a closed system. A thermal expansion tank or other approved means must control this pressure to protect piping and components.

Related: Pressure-Reducing Valve, Backflow Preventer
Trap Primer

A device or arrangement that supplies a small amount of water to a floor drain or similar trap to maintain its seal where infrequent use would otherwise allow evaporation to break the seal.

Related: Trap Seal, Floor Drain
Floor Drain

A drain fitting set in a floor to receive surface water and discharges. It requires a trap, must be accessible for cleaning, and often needs a trap primer where it is used infrequently.

Related: Trap Primer, Trap Seal, Cleanout
Gas Piping

The system of pipe, tubing, and fittings that conveys fuel gas from the point of delivery to appliances. Sizing, materials, support, and bonding are governed by code and manufacturer listing.

Related: Sediment Trap, Gas Connector, Combustion Air
Sediment Trap

A dirt pocket or drip leg installed at the appliance connection to capture debris and condensate before it reaches the gas controls. It must be installed in the direction the code and listing specify.

Related: Gas Piping, Gas Connector
Gas Connector

A listed flexible or semirigid connector used to join a gas appliance to the building piping. It must be sized for the appliance input, protected from damage, and not used to make rigid pipe runs.

Related: Gas Piping, Sediment Trap
Combustion Air

Air supplied to a fuel-burning appliance for proper combustion and draft. The code specifies opening sizes or mechanical means to provide adequate indoor or outdoor combustion air.

Related: Gas Piping, Water Heater
Water Heater

An appliance that heats potable water for domestic use. Installation requirements cover relief valves, discharge piping, seismic strapping, venting, and clearances from combustible construction.

Related: Temperature and Pressure Relief Valve, Combustion Air, Thermal Expansion
Temperature and Pressure Relief Valve

A safety device on a water heater that opens to relieve excess temperature or pressure. Its discharge must terminate in an approved location, typically outside or to a safe drain, without reduction in pipe size.

Related: Water Heater, Thermal Expansion
Fixture Clearance

The minimum unobstructed space required in front of and beside a plumbing fixture so it can be used and cleaned. Clearances vary by fixture type and are checked during plan review and inspection.

Related: Water Closet, Plan Review
Water Closet

A plumbing fixture that receives human waste and discharges it through a trap to the drainage system. Installation requires proper rough-in dimensions, clearance, water supply, and a code-compliant flush volume.

Related: Fixture Clearance, Trap Arm
Accessible Plumbing Fixture

A fixture designed and installed to be usable by people with disabilities, meeting requirements for height, reach, clearance, controls, and insulation of exposed piping, as referenced by accessibility standards.

Related: Fixture Clearance, Water Closet