IAPMO PPE flashcards
IAPMO PPE · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Uniform Plumbing Code
- IAPMO's model plumbing code establishing minimum requirements for plumbing installation, adopted with local amendments by the authority having jurisdiction in each jurisdiction.
- Authority having jurisdiction
- The official or agency responsible for enforcing the plumbing code, approving installations, issuing permits, and interpreting code provisions where the text is silent.
- Rough-in inspection
- Inspection performed after piping is installed and tested but before it is concealed by walls, floors, or ceilings, verifying code compliance of drains, vents, and water lines.
- Listed fixture
- A fixture or device evaluated by an approved testing agency and bearing its label, confirming compliance with recognized standards for the intended installation.
- Plumbing permit
- Official authorization required before installing, altering, or repairing a plumbing system; exempt work is defined in the code's administrative provisions.
- Code edition in force
- The specific published edition of the model code that a jurisdiction has formally adopted, which may differ from the most recently published edition.
- Existing installation
- Plumbing lawfully installed under a prior code edition, generally permitted to remain unless the code or authority having jurisdiction requires upgrade.
- Fixture unit
- A dimensionless measure of probable load a fixture places on the plumbing system, used to size both water supply and drainage piping.
- Drainage slope
- Required fall per unit length of horizontal drain; commonly one-quarter inch per foot for 2-inch pipe and one-eighth inch per foot for 3-inch pipe.
- Trap arm length
- Maximum distance from the trap weir to the vent connection, limited by pipe diameter per code tables to prevent self-siphonage of the trap.
- Vent stack sizing
- Determination of vent pipe diameter based on drainage fixture units connected and stack length, using code tables to ensure adequate air flow.
- Closet flange rough-in
- Distance from the finished wall to the center of the closet flange, commonly 12 inches, used to position the water closet drain correctly.
- Sanitary tee restriction
- A sanitary tee may connect a vertical drain to a horizontal branch but cannot be used where flow changes from horizontal to horizontal or horizontal to vertical drainage.
- T&P relief valve
- Temperature and pressure relief valve on a water heater, piped full size to a safe discharge location without traps, reductions, or uphill runs.
- Thermal expansion tank
- Device installed in a closed water system to absorb water expansion from heating, preventing excessive pressure buildup and protecting piping and fixtures.
- Residual pressure
- Water pressure measured while water is flowing; the code sets a minimum at fixtures during peak demand, commonly 8 psi.
- Static pressure
- Water pressure measured with no flow occurring, reflecting elevation and supply pressure without friction losses in the piping system.
- Probable demand
- Estimated peak water flow in gallons per minute derived from total supply fixture units using code tables, used to size water service and distribution piping.
- Velocity limit
- Maximum allowable water velocity in piping, typically about 8 feet per second cold and 5 feet per second hot, to limit noise and erosion.
- Building drain sizing
- Selection of drain pipe diameter based on total drainage fixture units and available slope, using code tables for horizontal drainage piping.
- Storm drainage sizing
- Sizing of roof drains and storm piping based on roof area and local rainfall intensity, kept separate from the sanitary drainage system.
- Water hammer arrestor
- Device installed near quick-closing valves to absorb pressure surges, preventing pipe noise and damage from sudden flow stoppage.
- Backwater valve
- Device installed on a drainage line to prevent sewage from reversing into a building, required where fixtures are below the upstream manhole elevation.
- Cross-connection
- Any actual or potential connection between potable water piping and a source of contamination or pollution that could allow backflow into the drinking water supply.
- Air gap
- Unobstructed vertical separation between a water supply outlet and the flood level rim of a receptor; the only absolute protection against backflow.
- Backsiphonage
- Backflow caused by negative or reduced pressure in the supply piping, drawing contaminated liquid into the potable water system.
- Backpressure
- Backflow caused when downstream pressure exceeds the supply pressure, forcing nonpotable liquid into the potable water system.
- RPZ assembly
- Reduced pressure zone backflow assembly providing protection against both backsiphonage and backpressure at high hazard, with test cocks and shutoff valves.
- Double check assembly
- Backflow assembly with two check valves providing protection against backsiphonage and backpressure at low hazard only, not high hazard.
- Pressure vacuum breaker
- Backflow device protecting against backsiphonage only, installed at least 12 inches above the highest downstream outlet and not subject to backpressure.
- Atmospheric vacuum breaker
- Backflow device protecting against backsiphonage only, installed at least 6 inches above the highest downstream point and not under continuous pressure.
- Annual backflow testing
- Requirement for certified testers to verify performance of reduced pressure and double check assemblies yearly, with results reported to the water authority.