ICC BCS flashcards
ICC BCS · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Occupancy classification purpose
- Assigning a use to an occupancy group establishes the baseline requirements for egress, fire separation, sprinkler thresholds, and allowable height and area.
- Type of construction
- A classification from I to V, with protected and unprotected subtypes, that limits building height and area based on combustibility and fire-resistance of structural elements.
- Allowable area calculation
- Tabular base area is adjusted by a frontage increase for open perimeter and a sprinkler increase, producing the maximum permitted floor area per story.
- Height in stories vs feet
- Both limits apply independently; a building must satisfy the story limit and the feet limit, and exceeding either one requires a different construction type or compliance alternative.
- Means of egress components
- The continuous path consists of exit access, the exit itself, and exit discharge, each governed by separate width, enclosure, and travel-distance provisions.
- Fire-resistance rating
- A time in hours that an assembly resists fire exposure under standardized testing, used to size fire barriers, fire walls, and opening protectives.
- Occupant load factor
- A floor area allowance per occupant assigned by use; dividing the floor area by this factor yields the occupant load used for egress sizing.
- Egress capacity
- Required width equals occupant load multiplied by the capacity factor for each egress component, with stairways and level components having different factors.
- Travel distance
- The measured length along the natural path from the most remote point to an exit, capped by occupancy-specific limits and often increased where sprinklers are provided.
- Common path of travel
- The distance a occupant must travel before reaching a point with two distinct routes, limited separately from total travel distance.
- Dead-end corridor limit
- A maximum corridor length with only one direction of escape, set by occupancy and sprinkler status to prevent occupants from being trapped.
- Remoteness of exits
- Where two exits are required, they must be separated so a single fire cannot block both, commonly by at least half the diagonal of the floor area.
- Mixed occupancy options
- Designers may apply the most restrictive provisions to the entire building or separate occupancies with rated fire barriers and evaluate each independently.
- Incidental use areas
- Small rooms such as mechanical or storage spaces that must be separated from the main occupancy by rated construction when they exceed listed size thresholds.
- Opening protective rating
- Doors and windows in rated walls require fire protection assemblies rated in proportion to the wall, often with a maximum rating cap for the opening.
- Fire wall vs fire barrier
- A fire wall divides a building into separate buildings for area purposes and must be structurally stable; a fire barrier separates spaces within one building.
- Sprinkler trade-offs
- Automatic sprinkler systems commonly permit increases in allowable area and travel distance and reductions in required fire separation and exit remoteness.
- Accessible route continuity
- An accessible path must connect site arrival points, entrances, and all accessible spaces without steps, using ramps or elevators where grade changes occur.
- Clear width at doors
- Door clear width is measured with the door open at ninety degrees, and the required dimension depends on occupant load and accessibility criteria.
- Alteration compliance methods
- The work area method scales upgrades to the portion altered, while the prescriptive method applies fixed improvements regardless of project scope.
- Change of occupancy review
- Moving to a more hazardous occupancy classification can trigger new fire separations, egress capacity, and sprinkler requirements even without new construction.
- Certificate of occupancy
- Issued after required inspections pass, it documents the approved use and occupant load and is required before a building may be legally occupied.
- Referenced standards role
- Adopted codes incorporate standards such as ASTM test methods and ASCE load criteria; those standards carry the force of code once referenced.
- Most restrictive provision rule
- Where code documents conflict, the requirement producing the greater level of safety or the more restrictive outcome is the one that governs design.
- Exit enclosure rating
- Interior exit stairways and ramps require fire-resistance-rated enclosures, with the rating set by building height and occupancy.
- Exit discharge requirement
- The path from the exit terminal to a public way must remain protected or be separated from the building, with limits on distance traveled outside.
- Number of exits threshold
- The required number of exits increases with occupant load, and each additional exit adds capacity and redundancy to the egress system.
- Horizontal exit
- A rated wall with openings protected so occupants can pass to an adjacent area of refuge, counting as an exit for egress capacity.
- Areas of refuge
- Designated spaces where occupants unable to use stairs can wait for assistance, required where accessible egress depends on elevators or protected areas.
- Guard and handrail height
- Guards protect open-sided walking surfaces above grade, and handrails along stairs and ramps must fall within specified height ranges for graspability.
- Stairway dimensional limits
- Riser height, tread depth, headroom, and landing dimensions are prescribed so that stairways maintain consistent and safe stepping geometry.
- Permit application content
- Submittal documents must show occupancy, construction type, and egress design sufficient for the official to determine code compliance before work begins.
- Inspector authority limits
- The building official may interpret code provisions and require corrected work, but approval does not waive the owner's duty to comply fully.