- Building official authority
- The building official's enforcement power comes from statute or local ordinance adopting the code, not from the code text itself; the official reviews, permits, inspects, and enforces.
- Stop-work order
- A written order halting work that is contrary to the code or the permit. Work may not resume until the building official authorizes resumption in writing.
- Right of entry
- Inspectors may enter premises at reasonable times to inspect. If entry is refused, the official must obtain a warrant or other legal process instead of forcing entry.
- Alternative materials approval
- The official may approve materials and methods not specifically prescribed by the code when the proposed alternative is at least equivalent in quality, strength, effectiveness, fire resistance, durability, and safety.
- Board of appeals role
- The board hears appeals of the building official's interpretations and decisions. Appeals must be filed within the ordinance's time limit and do not stay enforcement unless the board orders a stay.
- Permit lapse
- A permit becomes invalid if work does not start within the ordinance period, commonly 180 days, or if work is suspended or abandoned for the stated period after starting.
- Certificate of occupancy
- Issued after final inspection confirms the work complies with the permitted documents and code. A temporary certificate may be issued for a stated term with conditions.
- Change of occupancy review
- A change in use requires compliance with the new occupancy's requirements, including egress, fire separation, and applicable height and area limits for the construction type.
- Required inspection stages
- Typical required inspections are footing or foundation, framing, rough-in, insulation, and final. The permit holder must request each inspection when that stage is ready.
- Occupancy group letters
- Uses are classified as assembly A, business B, educational E, factory F, high-hazard H, institutional I, mercantile M, residential R, storage S, and utility U.
- Construction Type I versus V
- Type I is the most fire-resistive construction, with high ratings on structural elements. Type V is the least, and Type V-B is unprotected wood-frame construction.
- Mixed occupancy methods
- Mixed uses may be treated as accessory occupancies, nonseparated occupancies, or separated occupancies. Each method carries its own area, height, and fire-separation rules.
- Frontage increase
- Allowable building area may be increased where the building fronts a public way or open space. The increase is computed from the open perimeter and the code's frontage formula.
- Incidental use separation
- Small hazardous rooms such as boiler rooms, furnace rooms, and trash rooms require separation from the rest of the building by fire barriers with ratings from the incidental-use table.
- Means of egress components
- The means of egress consists of exit access, the exit, and exit discharge. Each component has separate requirements for width, protection, and travel distance.
- Occupant load calculation
- Occupant load equals floor area divided by the occupant load factor for the use. Fixed seating is counted by seat, and the calculated load may be increased where justified.
- Egress width rule
- Required egress width is based on occupant load, with different capacity per unit width for stairs versus level components. Width may not decrease along the path of travel.
- Remote exits requirement
- Where two exits are required, they must be separated by the code-specified distance so that a single fire cannot block both means of egress.
- Door swing threshold
- Egress doors must swing in the direction of travel where the occupant load is 50 or more, be side-hinged, and have panic hardware in certain assembly and educational occupancies.
- Exit enclosure
- An exit stair enclosure must be separated from the building by fire-resistance-rated construction and must discharge directly outside or through a protected exit passageway.
- Sprinkler threshold table
- The code's sprinkler threshold table shows where automatic suppression is required by occupancy, height, area, and construction type, and where it substitutes for fire resistance.
- Fire wall function
- A fire wall divides a building into separate buildings for area and height purposes. It must be structurally independent, and openings must have fire-rated protective assemblies.
- Smoke barrier versus partition
- Smoke barriers resist smoke migration and are required in institutional and some assembly occupancies. Smoke partitions have lesser requirements and serve different containment purposes.
- Standpipe trigger
- Standpipes are required where the highest occupied floor exceeds the code's height threshold and in certain large-area buildings, so hose lines can reach all floors.
- Live load reduction limits
- Live loads may be reduced only as the code permits, based on tributary area and number of floors supported. Reductions are not allowed for certain occupancies such as public assembly.
- Accessible route
- An accessible route must connect the site arrival point, building entrance, and all accessible spaces. Changes in level must be ramped or otherwise resolved within code limits.
- Path of travel upgrade
- Alterations and additions trigger accessibility upgrades to the path of travel serving the altered area, capped at a cost limit proportional to the project cost.
- Special inspection trigger
- The code requires special inspection and testing for specified elements such as high-strength bolting, welding, and certain foundations, performed by approved agencies.
- Existing building work classes
- Existing building provisions classify work as repair, alteration, addition, or change of occupancy. Each class sets the level of code compliance required for the work.
- Energy code documentation
- Energy compliance is shown by prescriptive or performance methods. The building official verifies that permit documents include the required compliance documentation before issuing the permit.
- Partial occupancy approval
- A portion of a building may be occupied before completion only where it meets all life-safety requirements, including egress, fire separation, and fire-protection systems.
- Concealed work inspection
- Work that will be concealed must be inspected and approved before it is covered. Approval of one stage does not relieve the permit holder of responsibility for overall compliance.