Administration, Scope and Enforcement of the Residential Energy Code

  • Residential scope covers detached one- and two-family dwellings and townhouses not more than three stories above grade plane, plus associated systems and sites.

  • Construction documents must identify the compliance path and show envelope, mechanical, water heating, and lighting information needed for inspection.

  • A permit is required before new construction, alteration, addition, or change of occupancy regulated by the code.

  • The building official enforces the code and may require approved inspections, tests, and third-party verification.

  • A permanent energy certificate must list insulation R-values, fenestration U-factors/SHGC, HVAC efficiencies, and water heating efficiencies.

  • Mandatory provisions-such as air sealing and equipment efficiency-apply even when the project uses a performance or ERI path.

  • Alternate materials or methods require approval by the building official based on demonstrated compliance with code intent.

  • Additions, alterations, repairs, and changes of occupancy must comply with the provisions applicable to the scope of work; unaltered portions are generally not retrofitted.

Quick reference

Building Envelope (Insulation, Fenestration, Air Leakage)

  • Envelope compliance requires meeting insulation, fenestration, and air-leakage requirements for the project's climate zone.

  • Insulation R-values are selected from the adopted envelope table based on assembly type: ceiling, wall, floor, slab edge, basement, or crawl space.

  • Fenestration must meet maximum U-factor and, where required, maximum SHGC values; skylights often have separate limits.

  • The building thermal envelope must be continuously sealed to form an air barrier at joints, penetrations, sill plates, and fenestration.

  • Tested air leakage must not exceed 5 ACH50 in climate zones 3–8 or 6 ACH50 in climate zones 1–2 under the 2021 residential provisions.

  • Recessed luminaires in insulated ceilings must be IC-rated and sealed to limit air leakage into or out of the envelope.

  • Access hatches and doors to unconditioned attics or crawl spaces must be insulated and weatherstripped.

  • Slab-edge and foundation insulation requirements depend on climate zone and assembly; insulation must be installed to the required depth or R-value.

  • Insulation must fill cavities and be installed without gaps, compression, or misalignment that reduce rated R-value.

Quick reference

Mechanical Systems (Heating, Cooling, Ventilation, Ducts)

  • HVAC equipment must be sized with ACCA Manual J or an approved load calculation, and ducts designed with Manual D.

  • Equipment must meet the minimum efficiency ratings in the adopted code or federal standards; ratings are verified by AHRI or manufacturer data.

  • Ducts outside conditioned space must be insulated to the adopted table R-value; supply ducts in attics often need higher R-value.

  • Ducts, plenums, boots, and air handlers must be sealed; duct leakage testing is required unless all ducts and air handler are in conditioned space.

  • Duct leakage limit is commonly 4 cfm per 100 ft² of conditioned floor area at 0.1 in. w.c. (25 Pa) across the system.

  • Whole-house mechanical ventilation must be provided and sized per ASHRAE 62.2 or an approved method.

  • Bath exhaust must be ducted outdoors; intermittent rates are commonly 50 cfm for baths and 100 cfm for kitchens, with lower continuous rates.

  • HVAC piping and refrigerant lines requiring insulation must be insulated per the adopted table to prevent energy loss.

  • Heating and cooling systems must have a thermostat capable of controlling the system; some adopted editions require setback or programmable capability.

Quick reference

Service Water Heating

  • Water heaters must meet minimum efficiency standards for fuel type and size; verify with AHRI or manufacturer ratings.

  • Hot water piping from the water heater and in unconditioned spaces must be insulated to the code-required R-value.

  • Circulating hot water systems require insulated piping and automatic controls that disable circulation when demand is low.

  • Heated pools require a vapor-retardant cover or approved evaporation-reducing measure and may require pool heater controls.

  • Pool heaters must have a readily accessible on/off switch and may require time clocks or automatic shutoff controls.

  • Solar water heating systems and drain-water heat recovery must be listed and installed per manufacturer instructions and referenced standards.

  • Water heater tanks and piping must be installed to limit heat loss, with insulation not covering safety devices or access.

  • Point-of-use water heaters must meet efficiency and installation requirements; storage units are subject to standby loss limits.

Quick reference

Electrical Power

  • Lighting efficacy is lumens per watt; high-efficacy fixtures use lamps such as LEDs that meet the adopted threshold.

  • A minimum percentage of permanently installed lighting fixtures must contain high-efficacy lamps where the adopted edition retains that requirement.

  • Exterior lighting must be controlled by a photocell, time switch, or other automatic control.

  • Solar-ready provisions, where adopted, require a designated roof area and conduit pathway to the service panel.

  • EV-ready provisions, where adopted, require reserved electrical capacity and a pathway for future EV charging.

  • Electrical power provisions may require energy monitoring or metering in some adopted editions; verify the edition in force.

  • Lighting and electrical equipment must be listed and labeled for the application and installed per manufacturer instructions.

  • Dwelling-unit electrical distribution must provide capacity for required equipment; load calculations follow the electrical code, not energy code tables.

Quick reference

Lighting and Appliances

  • Permanently installed lighting fixtures must meet efficacy requirements; the percentage and efficacy threshold depend on the adopted code edition.

  • Federal appliance efficiency standards set minimum performance for refrigerators, dishwashers, clothes washers, and similar appliances.

  • EnergyGuide labels disclose estimated annual energy use or cost but do not replace code or federal compliance documentation.

  • Clothes dryers, ranges, and ovens are generally covered by federal standards or labeling rather than residential energy-code tables.

  • Pool pumps and heaters must have controls such as timers; larger pools may require variable-speed pumps under adopted provisions.

  • Ceiling fans and other appliances may be subject to labeling or efficiency rules; verify the adopted edition and federal preemption.

  • Lighting controls such as vacancy sensors may be required in some adopted editions for specific spaces.

  • Appliances and lighting must be installed per listing and manufacturer instructions; improper installation can void efficiency ratings.

Quick reference

Compliance Paths

  • Prescriptive path: each envelope, mechanical, water heating, and lighting component meets its individual code requirement.

  • Performance path: approved software shows proposed annual energy cost is no greater than the standard reference design.

  • ERI path: a certified rater calculates an Energy Rating Index; lower scores mean better performance and must meet the climate-zone threshold.

  • Mandatory requirements apply to every compliance path and cannot be traded away in performance or ERI modeling.

  • The total UA alternative allows envelope trade-offs when overall heat loss coefficient does not exceed the baseline.

  • Performance and ERI software must be approved by the code official and use the code's standard reference design assumptions.

  • Compliance documentation must be retained and available to the building official; ERI requires a certified HERS or equivalent report.

  • Additions and alterations may use prescriptive or performance methods where allowed, but the scope of work determines which requirements apply.

Quick reference

Referenced Standards and Existing Buildings

  • Referenced standards are enforceable parts of the code; the edition cited in the adopted code governs.

  • ASHRAE 62.2 is referenced for residential ventilation sizing and indoor air quality.

  • ACCA Manual J, D, and S are referenced for load calculation, duct design, and equipment selection.

  • ANSI/RESNET/ICC 380 is referenced for duct and envelope leakage testing where adopted.

  • AHRI directories or manufacturer data verify equipment efficiency ratings used for compliance.

  • Existing buildings: additions and alterations must comply for the scope of work; repairs have limited requirements.

  • Historic buildings may be exempt or subject to alternative requirements where the code official determines compliance would be infeasible.

  • The building official may approve alternative materials or methods when performance is demonstrated by test data or approved analysis.

  • Replacement equipment must meet the efficiency requirements of the adopted code unless a specific existing-building exception applies.