Acceptance testing
Verification that a new medical device meets manufacturer specifications and local safety standards before clinical use, including electrical safety, performance, and documentation.
Preventive maintenance
Scheduled inspection, cleaning, calibration, and performance verification of medical equipment to prevent failures and ensure safe operation, typically based on manufacturer recommendations and risk level.
Risk-based PM
A maintenance strategy that prioritizes devices by function, physical risk, incident history, and maintenance requirements, allocating more frequent attention to higher-risk equipment.
MTBF
Mean time between failures, calculated as total operating time divided by number of failures; used to assess reliability and plan equipment replacement.
FDA device classes
Class I (low risk, general controls), Class II (moderate risk, general and special controls, often 510(k)), Class III (high risk, premarket approval).
510(k) premarket notification
A FDA submission demonstrating that a new device is substantially equivalent to a legally marketed predicate device, allowing marketing without clinical trials.
Medical Device Reporting
FDA requirement for manufacturers and user facilities to report device-related deaths, serious injuries, and malfunctions to detect and address safety issues.
Recall classes
Class I: reasonable probability of serious adverse health consequences or death; Class II: temporary or reversible health consequences; Class III: unlikely to cause harm.
Ground continuity test
Electrical safety test verifying low resistance (typically <0.5 Ω) between the protective earth pin and exposed conductive parts, ensuring a safe fault current path.
Leakage current limits
IEC 60601-1 limits: earth leakage ≤500 µA normal; patient leakage ≤100 µA (Type B/BF) or ≤10 µA (Type CF) under normal conditions.
Defibrillator energy test
Verification that delivered energy is within ±15% of selected energy, charge time is acceptable, and synchronized cardioversion timing is accurate.
Calibration traceability
An unbroken chain of measurements linking test equipment to national or international standards (e.g., NIST) with documented uncertainty.
CMMS
Computerized maintenance management system: software tracking equipment inventory, work orders, PM schedules, parts, and costs for healthcare technology management.
MTTR
Mean time to repair: average time to restore a failed device to service, a key performance indicator for maintenance efficiency.
Capital equipment planning
Aligning technology acquisition with clinical strategic goals and budget cycles, including needs assessment, prioritization, and lifecycle cost analysis.
Technology assessment
Evaluation of clinical efficacy, safety, cost-effectiveness, and integration of a medical technology to inform adoption and management decisions.
HIPAA Security Rule
Requires administrative, physical, and technical safeguards to protect the confidentiality, integrity, and availability of electronic protected health information (ePHI).
Network segmentation
Isolating medical devices from enterprise IT networks to limit attack surface, contain breaches, and protect clinical operations.
HL7
A standard for exchanging clinical and administrative health data between healthcare information systems, enabling interoperability.
DICOM
A standard for storing, transmitting, and displaying medical imaging information, ensuring interoperability among imaging devices and systems.
Ohm's law
V = I × R; voltage equals current times resistance. Power P = V × I = I²R = V²/R.
Impedance
Total opposition to alternating current, combining resistance and reactance: Z = √(R² + X²), where X is reactance.
CMRR
Common-mode rejection ratio: a differential amplifier's ability to reject common-mode signals; higher values improve signal quality in biopotential measurements.
Microshock
Very small current (as low as ~100 µA) applied directly to the heart, which can cause ventricular fibrillation; requires strict isolation in intracardiac procedures.
Cardiac conduction system
SA node (pacemaker), AV node (delay), bundle of His, bundle branches, and Purkinje fibers, coordinating atrial and ventricular contraction.
ECG waveforms
P wave (atrial depolarization), QRS complex (ventricular depolarization), T wave (ventricular repolarization).
Cardiac output
Heart rate multiplied by stroke volume; normal resting value approximately 5 L/min.
Pulse oximetry
Noninvasive measurement of arterial oxygen saturation (SpO2) using light absorption; normal range 95–100%.
Environment of care
Standards addressing safety, security, hazardous materials, fire safety, medical equipment, and utilities to provide a safe healthcare facility.
Emergency power testing
Monthly and annual testing of emergency generators and essential electrical systems to ensure backup power for life safety and critical care.
Medical gas systems
Piped oxygen, vacuum, medical air, and other gases requiring verification, labeling, and alarm systems to ensure patient safety.
Clinical engineering ethics
Professional principles emphasizing patient safety, competence, confidentiality, integrity, and disclosure of conflicts of interest.