Refrigeration cycle
A closed loop in which refrigerant is compressed, condensed, expanded, and evaporated to move heat from a cold space to a warmer surroundings.
Evaporator function
The heat exchanger where low-pressure liquid refrigerant boils and absorbs heat from the space or product being cooled.
Condenser function
The heat exchanger where high-pressure hot refrigerant vapour gives up heat to the surrounding air or water and condenses to liquid.
Compressor role
It raises the pressure and temperature of refrigerant vapour, creating the pressure difference that drives flow around the whole circuit.
Expansion valve
A metering device that throttles high-pressure liquid refrigerant to low pressure and controls the flow into the evaporator.
Superheat
The number of degrees a vapour is above its saturation temperature at the same pressure; measured at the evaporator outlet.
Subcooling
The number of degrees liquid refrigerant is below its saturation temperature at the same pressure; measured at the condenser outlet.
Coefficient of performance
The ratio of refrigerating effect produced to the work input of the compressor; higher values indicate a more efficient cycle.
Saturation temperature
The boiling or condensing temperature of a refrigerant at a given pressure; it rises as pressure rises and falls as pressure falls.
Latent heat
Heat absorbed or released during a change of state without a change in temperature, such as boiling or condensing refrigerant.
Sensible heat
Heat that changes the temperature of a substance without changing its state, such as warming air across a coil.
Non-condensable gases
Air or other gases that do not condense in the condenser; they raise discharge pressure and reduce system capacity.
Refrigerant leak symptoms
Low suction pressure, high superheat, bubbles in the sight glass, and reduced cooling capacity often indicate a refrigerant charge loss.
Liquid line sight glass
A window in the liquid line used to observe refrigerant flow; continuous bubbles suggest a shortage of liquid refrigerant.
Moisture in system
Water contamination can freeze at the expansion valve and form acids; filter driers and evacuation remove it during service.
Evacuation
Removing air and moisture from a system with a vacuum pump before charging, verified by holding a deep vacuum.
Recovery of refrigerant
Removing refrigerant from a system into a suitable container for reuse, recycling, or disposal rather than venting it to atmosphere.
Air conditioning purpose
It controls air temperature, humidity, cleanliness, and movement to provide comfortable or process-required indoor conditions.
Dry-bulb temperature
The ordinary air temperature measured by a thermometer exposed to the air, unaffected by moisture or radiant heat.
Wet-bulb temperature
The temperature of air measured with a wetted bulb; it reflects evaporative cooling and indicates moisture content and humidity.
Relative humidity
The amount of water vapour in air expressed as a percentage of the maximum the air could hold at that temperature.
Dew point
The temperature to which air must be cooled for water vapour to condense; cooling below it produces condensate.
Latent heat of vaporisation
The heat needed to change a liquid to vapour at constant temperature; for water it is about 2260 kJ per kg.
Specific heat capacity
The heat needed to raise one kilogram of a substance by one kelvin; for water it is about 4.18 kJ/kg·K.
Heat load
The total heat that must be removed from a space, including product, transmission, people, lights, and equipment gains.
Ton of refrigeration
A cooling rate equal to 3.517 kW, the heat needed to melt one short ton of ice in 24 hours.
Pressure-enthalpy diagram
A chart plotting refrigerant pressure against enthalpy, used to calculate refrigerating effect, work, and system performance.
Discharge pressure
The high-side pressure at the compressor outlet; it rises with condensing temperature and with non-condensable gases.
Suction pressure
The low-side pressure at the compressor inlet; it corresponds to the evaporating temperature and influences cooling capacity.
Head pressure control
Methods that maintain adequate condenser pressure in cold weather, such as fan cycling, dampers, or receiver pressure regulators.
Thermostatic expansion valve
A valve using a sensing bulb to regulate refrigerant flow and keep a set superheat at the evaporator outlet.
Filter drier
A device in the liquid line that traps moisture and solid particles to protect the expansion valve and compressor.
Air-cooled condenser
A condenser that rejects heat to ambient air moved across its coils by fans; capacity depends on air temperature and airflow.