31 cards. Read the term and the definition here. The deck at the top of this page is optional.

Pascal's principle
Pressure applied to a confined fluid is transmitted undiminished in all directions, allowing force multiplication in hydraulic systems with different piston areas.
Flow continuity equation
For steady flow in a closed system, Q = A × v, meaning flow rate equals cross-sectional area times fluid velocity; velocity rises as area decreases.
Hydraulic power formula
Power equals pressure times flow rate. In US units, horsepower = (psi × gpm) / 1714; in SI, watts = pascals × cubic meters per second.
Gauge versus absolute pressure
Gauge pressure is measured relative to atmospheric pressure, while absolute pressure equals gauge pressure plus atmospheric pressure, about 101.3 kPa.
Boyle's law
At constant temperature, the product of pressure and volume of a fixed gas mass is constant: p1V1 = p2V2. Applies to pneumatic compression and expansion.
Force multiplication ratio
Output force divided by input force equals the ratio of output piston area to input piston area; greater output force comes with proportionally shorter stroke.
Cylinder extend force
Extend force equals system pressure times the full bore area. This is the maximum force a cylinder can produce during extension.
Cylinder retract force
Retract force equals pressure times the annulus area, which is bore area minus rod area. It is always less than extend force for the same pressure.
Relief valve function
A normally closed, pressure-actuated valve that opens to bypass flow to tank when system pressure exceeds a set value, protecting components from overpressure.
Tandem center valve
A directional valve center condition that connects the pressure port to tank while blocking both work ports, allowing the pump to unload at low pressure.
Meter-out flow control
A flow control valve placed in the actuator exhaust line to regulate speed; it provides back pressure and stabilizes motion against overrunning loads.
Accumulator precharge
The gas charge set in a bladder or piston accumulator before installation; it is typically set below minimum system working pressure to allow usable fluid storage.
Beta ratio
The ratio of particles upstream to particles downstream of a filter at a specified micron size; higher beta values indicate better filtration efficiency.
ISO VG viscosity grade
A classification of hydraulic fluid viscosity measured at 40 °C; for example, ISO VG 46 has a nominal viscosity of 46 mm²/s.
Pneumatic force variability
Because air is compressible, pneumatic cylinder force varies with load and flow; force is not constant through the stroke, unlike hydraulics.
FRL unit
An air preparation assembly combining a filter to remove water and particles, a regulator to set pressure, and a lubricator to add oil mist downstream.
Free air delivery
The volume of air a compressor delivers referenced to standard atmospheric conditions, used to compare compressor capacity independent of working pressure.
Meter-out pneumatic control
Speed control achieved by restricting exhaust air from the cylinder; preferred in pneumatics because it stabilizes motion with overrunning loads.
Refrigerated air dryer
A dryer that cools compressed air to condense moisture, achieving pressure dew points around +3 °C, suitable for general industrial use.
Desiccant air dryer
A dryer using moisture-absorbing material to reach pressure dew points of −40 °C or lower, used where very dry air is required.
Rotary screw compressor
A positive displacement compressor using two intermeshing rotors to compress air continuously; common in industrial plants for steady-duty compressed air supply.
Shuttle valve function
A pneumatic logic valve that passes the higher of two input pressures to the output, performing an OR function in pneumatic circuits.
Double-solenoid valve
A directional valve with two solenoids and detents that holds its last position when both solenoids are de-energized, providing memory function.
Proportional valve
An electrically controlled valve whose flow or pressure output varies proportionally with input current or voltage, offering control between on-off and servo performance.
LVDT feedback
A linear variable differential transformer that measures spool or valve position and provides feedback for closed-loop control of proportional and servo valves.
Sinking versus sourcing
Sinking (NPN) sensors switch the load to ground; sourcing (PNP) sensors switch the load to positive supply. PLC input type must match the sensor.
PLC output types
Relay outputs handle AC and higher currents, transistor outputs switch DC quickly for high cycle rates, and triac outputs switch AC loads.
Emergency stop category
Per ISO 13850, an emergency stop is a category 0 (immediate power removal) or category 1 (controlled stop then power removal) action.
Performance Level
A rating from ISO 13849-1 (PL a through e) describing the reliability of a safety-related control system against random and systematic failures.
Valve null offset
The spool position where flow is zero; null shift causes drift in proportional valve control and requires adjustment or closed-loop correction.
Three-phase power formula
For balanced three-phase AC, real power P = √3 × V × I × power factor, where V is line voltage and I is line current.