Applied Microbial Remediation Technician study materials
Applied Microbial Remediation Technician study resources

Applied Microbial Remediation Technician cheat sheet

Applied Microbial Remediation Technician · Keep the key ideas within reach.

Quick reference

Mold Remediation Techniques

  • Moisture source control precedes any removal: porous materials that stay above roughly 60% equilibrium moisture content or 16% wood moisture content support mold growth, so drying or repair must be documented before remediation is called complete.

  • Category 3 water (grossly contaminated) and mold contamination in HVAC systems are both triggers for containment; an HVAC system serving a mold-affected area must be isolated or the system itself remediated.

  • Containment decision rule: use critical barriers for small isolated areas, full containment with negative pressure (typically -5 to -10 Pa relative to adjacent spaces) and HEPA filtration for areas large enough that airborne spore release could reach occupied spaces.

  • Removal rule: porous materials with more than a small, surface-level area of mold growth are removed and discarded rather than cleaned; non-porous and semi-porous surfaces can be cleaned when structurally sound.

  • HEPA vacuuming is the only acceptable vacuum method during mold work; standard shop vacuums exhaust respirable particles and are not permitted in containment.

  • Biocide use follows cleaning, not replacement for it: dead spores remain allergenic and must be removed physically; a biocide is applied only after the surface is clean and only when the label permits the substrate.

  • Post-remediation verification is not the remediator's self-approval: clearance requires an independent assessment of settled spores, airborne spores, and visible condition in the work area.

  • Personal protective equipment for mold work: at minimum N-95 or better respiratory protection, eye protection, and gloves; full-face or powered air-purifying respirators are used when concentrations or work methods generate heavy aerosol.

Quick reference

Sewage Remediation Techniques

  • Water categories: Category 1 is sanitary, Category 2 is significantly contaminated (contains some harmful agents), Category 3 is grossly contaminated and includes sewage; Category 3 contamination degrades lower categories on contact.

  • Sewage is Category 3 water; porous materials contacted by it (carpet, pad, upholstered furniture, drywall, insulation) are removed and discarded rather than dried in place.

  • Category 3 water intrusion requires antimicrobial treatment of affected structural surfaces after removal of porous materials, and drying must be documented before reconstruction.

  • Black water (sewage) carries pathogens including bacteria, viruses, and parasites; the remediation plan must include disinfection of all contacted surfaces and protection of unaffected areas from cross-contamination.

  • Structural drying targets: wood framing is dried toward 16% moisture content or below, and materials are compared against a dry standard taken from an unaffected area of the same material.

  • Containment and engineering controls for sewage work: isolation of the affected area, negative air pressure where feasible, HEPA filtration, and exclusion of occupants until clearance.

  • Waste handling: sewage-contaminated debris is bagged or wrapped, transported in a covered container, and disposed of according to local regulations; workers do not eat, drink, or smoke in the work area.

  • Clearance for sewage work: visible cleanliness, no residual odor, and documented disinfection; an independent post-remediation evaluation is used to confirm the area is safe for reoccupancy.