Floor Care Technician flashcards
Floor Care Technician · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Saponification
- The alkaline conversion of fats and oils into water-soluble soap, which is why high-pH cleaners cut grease effectively but can damage wool and dull floor finish.
- Dwell time
- The period a cleaning solution stays on the surface before agitation, allowing detergent to emulsify soil; usually 3-10 minutes for floor cleaners.
- 1:64 dilution
- A mixing ratio meaning one part concentrate to 64 parts water, equal to 2 fluid ounces of product per gallon of water.
- Neutral cleaner
- A cleaner with pH near 7 that lifts light soil without attacking floor finish, making it the default for routine damp mopping of finished floors.
- Acidic cleaner use
- Low-pH products dissolve mineral scale, rust, and hard-water film, but they etch marble, terrazzo, and concrete and should not contact those surfaces.
- Particulate soil
- Dry grit, sand, and dust that should be removed before wet cleaning, because wetting it turns it into an abrasive slurry that scratches finish.
- Color-coded mopping
- A zone system assigning distinct mop and bucket colors to restrooms, food areas, and general spaces to prevent cross-contamination between areas.
- Wicking
- The upward migration of soil or moisture through carpet backing and pile during drying, which leaves recurring spots unless the source is extracted and dried.
- Over-concentration residue
- Sticky film left when cleaner is mixed stronger than the label ratio; it attracts soil and makes the floor re-soil faster than a correctly diluted application.
- Grazing-angle inspection
- Holding a bright light low and nearly parallel to the floor so scratches, swirls, and gloss variation become visible instead of washing out under overhead light.
- Gloss meter reading
- A 60-degree reflectance measurement in gloss units; compare against a baseline for the same product rather than a universal pass threshold.
- Finish blush
- A whitish haze in floor finish caused by moisture trapped under the film, typically from applying coats before the previous coat dried or in high humidity.
- Finish yellowing
- A gradual amber discoloration of floor finish, usually from excessive coat build, repeated recoating without stripping, or incompatible products.
- Calcium chloride test
- ASTM F1869 method that measures moisture vapor emission from a concrete slab before coating or flooring installation to predict adhesion failure.
- In-situ RH probe
- ASTM F2170 method placing a probe in a drilled hole in concrete to measure internal relative humidity, a more direct moisture check than surface tests.
- Straightedge flatness check
- Laying a 10-foot straightedge on the subfloor and measuring gaps; resilient flooring generally tolerates about 3/16 inch deviation in 10 feet.
- Telegraphing
- Subfloor defects, debris, or texture showing through thin resilient flooring as bumps or ridges, indicating surface preparation was inadequate.
- Soil transfer test
- Rubbing a suspect mark with a white cloth and neutral cleaner; transfer means soil, no transfer means finish damage or substrate defect.
- Coating failure taxonomy
- A classification of finish problems into scratches, scuffs, blush, yellowing, and peeling, each with a distinct cause and repair path.
- Baseline documentation
- A recorded set of photos, gloss readings, dates, and product data taken at the same locations each cycle to support wear claims and scheduling.
- Seam and cove inspection
- Probing seams, cove base, and thresholds for gaps or lift, since these edges admit water and are common origins of subfloor damage.
- Stripping sequence
- Dry soil removal, stripper application, dwell, agitation, wet-vac of slurry, two clean-water rinses, and full drying before any new finish.
- Stripper incompatibility
- High-pH strippers react dangerously with acids and chlorine products, releasing heat or gas, so mixing chemicals during stripping is prohibited.
- Thin-coat finish rule
- Applying multiple thin coats, each dried to touch before the next, prevents trapped solvent, blush, and uneven film build.
- Sealer versus finish
- Sealer bonds to the substrate and fills porosity; finish forms the wear layer and gloss. Both are used together on porous resilient tile.
- High-speed burnishing
- Running a 1500-3000 rpm machine with a soft pad to restore gloss on cured finish; excess heat or pressure burns the film permanently.
- Screen and recoat
- Lightly abrading a clean finish with a screen or pad, then applying new coats, which restores gloss without a full strip and rebuild.
- Spot stripping
- Removing finish from an isolated damaged area, neutralizing, and recoating to blend with surrounding film, avoiding a full-floor strip.
- Full strip trigger
- A full strip and rebuild is indicated when finish is contaminated, yellowed, peeling, or has too many coats to recoat evenly.
- Cure and traffic window
- Typical floor finish accepts foot traffic in 30-60 minutes, furniture after 24 hours, and heavy rolling loads after 24-72 hours.
- Carpet drying window
- Extracted carpet should dry within 24-48 hours using air movers; slower drying promotes mold, delamination, and recurring wicking spots.
- Power stretching
- Using a power stretcher to re-tension loose carpet from the wall rather than patching, restoring a taut surface and closing stretched seams.