Illinois Elevator Safety Act
The Illinois statute (225 ILCS 320) that establishes licensing, permitting, and inspection authority for elevators and escalators in the state.
ASME A17.1 scope
The Safety Code for Elevators and Escalators covering electric and hydraulic elevators, escalators, moving walks, and material lifts, with separate Parts for each equipment type.
Escalator maximum rise
A single escalator unit is limited to a maximum rise of 60 ft unless a code variance is granted by the authority having jurisdiction.
Escalator step width
Escalator steps are furnished in nominal widths of 24 in (600 mm) or 40 in (1000 mm), and the step edges must be marked with a contrasting color.
Combplate clearance limit
The combplate teeth must mesh with the step cleats with a total clearance not exceeding 3/16 in (4.8 mm) in the direction of travel.
Certificate of operation
A document issued after a satisfactory inspection that must be posted in the car and shows the inspection date and expiration date.
Traction drive principle
A sheave driven by a geared or gearless machine pulls ropes over the sheave to raise the car, with a counterweight balancing part of the load.
Counterweight balance
The counterweight typically balances the car weight plus about 40-50% of the rated load, reducing the machine's required lifting effort.
Hydraulic relief valve setting
The relief valve must be set to open at no more than 2.5 times the pressure required to lift the rated load, protecting the system from overpressure.
Telescopic jack
A hydraulic jack with multiple concentric plungers that extend in stages, allowing a long car rise with a shorter overall jack length.
2:1 roping
A reeving arrangement in which the rope travels twice the car distance and the rope tension is half the load, so rope speed is twice car speed.
Governor tripping speed
The speed at which the governor trips and applies the car safety, typically set at 115-125% of the car's rated speed.
Safety chain
A series circuit of normally closed switches, including pit, car top, door locks, governor, and final limits, that stops the car when any switch opens.
Door interlock function
A positively operated device that prevents the car from starting unless the landing door is closed and locked, and is part of the safety chain.
Variable-frequency drive
An electronic motor controller that varies the frequency and voltage supplied to an AC induction motor for smooth acceleration and accurate leveling.
Main line disconnect
A lockable switch that opens all ungrounded conductors and is located where it is accessible to the mechanic, not in the hoistway or pit.
Equipment grounding conductor
A conductor, identified green or green with yellow stripe, that bonds the machine, controller, and car frame to ground for fault protection.
Car safety
A governor-operated device that applies wedges or rollers to the guide rails to stop and hold the car when it overspeeds in the down direction.
Governor tension sheave
A weighted sheave that keeps the governor rope under tension so the governor can trip the safety if the rope goes slack or breaks.
Final limit switch
A separate, non-resettable switch that stops the car if it overtravels past the normal terminal landing and must be reset by a mechanic.
Door reopening device
A mechanical safety edge or infrared curtain that reverses the door on contact or obstruction, with reopening force limited by code.
Annual safety test
A documented test by a licensed mechanic covering the car safety, governor, buffers, door interlocks, and counterweight safety.
Pit ladder requirement
A securely fastened ladder providing pit access without moving the car, with rungs spaced not more than 12 in apart and extending near the pit floor.
Fire service Phase I
A key switch that recalls the car to the designated landing and opens the doors when a fire alarm is received.
Fire service Phase II
A mode that allows firefighters to control the car with the doors open under restricted conditions using the in-car key switch.
Insulation resistance test
A megger test performed with the circuit de-energized and isolated; a reading below the manufacturer's minimum indicates degraded insulation.
Oil buffer
A buffer required for car speeds above 200 ft/min that uses oil to absorb impact energy and must be kept filled to the marked level.
Brake holding capacity
The traction machine brake must set automatically when power is removed and hold 125% of rated load without slipping.
Rupture valve
A hydraulic valve that closes to stop oil flow and prevent a runaway car if a pipe or fitting ruptures.
Escalator emergency stop
A clearly marked button at each landing that stops the escalator within the code's stopping distance when pressed.
Skirt guard clearance
The gap between the escalator step and the skirt panel, checked with a gauge to prevent entrapment of shoes or clothing.
Machine room requirements
The machine room must be locked, ventilated, kept within the equipment's temperature rating, and not used for storage of unrelated materials.