Luminous flux
Total light output emitted by a source in all directions, measured in lumens (lm). Luminaire lumen output is the basis for illuminance calculations and efficacy comparisons.
Illuminance
Light arriving at a surface per unit area, expressed in lux (lm/m²) or footcandles. One footcandle equals about 10.76 lux. Horizontal illuminance is used for roadway design criteria.
Luminance
Light reflected or emitted from a surface in a given direction, measured in candela per square meter (cd/m²). Roadway luminance and its uniformity drive driver visibility and comfort.
Coefficient of utilization
Fraction of luminaire lamp lumens that reaches the roadway surface, depending on luminaire distribution, mounting height, geometry, and surface reflectances. Used in the lumen method.
Light loss factor
Product of lamp lumen depreciation, luminaire dirt depreciation, ballast or driver factor, and ambient factors. Converts initial lumens to maintained lumens for design calculations.
Mesopic vision
Vision state at intermediate light levels where both rod and cone photoreceptors contribute. Higher correlated color temperature sources can improve perceived brightness at equal photopic luminance.
Veiling luminance ratio
Ratio of maximum veiling luminance from glare to average roadway luminance. Standards cap this ratio to limit disability glare, with stricter limits at higher design speeds.
Luminance uniformity ratio
Ratio of maximum to minimum (or average to minimum) roadway luminance. Uniformity limits prevent alternating bright and dark patches that impair driver detection.
IES roadway classification
Categories such as freeway, arterial, collector, and local road that set design criteria. Higher speed and volume classifications require higher luminance and stricter uniformity.
BUG rating
Backlight, uplight, and glare rating system for outdoor luminaires. Local ordinances use BUG ratings to limit light trespass, skyglow, and glare.
NEC Article 410
National Electrical Code article covering luminaires, lamp holders, and associated equipment. It sets installation, support, and wiring requirements but does not set photometric design levels.
Warrant analysis
Study of roadway classification, traffic volume, pedestrian activity, and nighttime crash history to decide whether lighting is justified. Results support funding and design decisions.
LED driver
Power supply converting AC line voltage to regulated constant current for LED modules. Output current, forward voltage range, dimming protocol, and programming must match the luminaire.
L70 lumen maintenance
Projected operating hours when LED lumen output falls to 70 percent of initial. Values are extrapolated using TM-21 methods from measured LM-80 data.
High-pressure sodium lamp
Arc discharge source with high efficacy and warm orange light. Requires a ballast with ignitor and capacitor; its low color rendering limits use where color matters.
Ballast factor
Ratio of lamp lumens produced on a given ballast to lumens on a reference ballast. It scales both light output and input power in fluorescent and HID systems.
IES distribution type
Luminaire light pattern classification from Type I (narrow, along roadway) to Type V (symmetric). Type and cutoff classification determine spacing and glare control.
IP rating
Ingress protection code giving resistance to dust and water, such as IP65 or IP66. It indicates suitability of luminaire and driver enclosures for outdoor roadway environments.
Effective projected area
Wind-facing area of luminaire and arm, used with wind pressure to compute pole loads. Manufacturer EPA values feed structural calculations for poles and foundations.
Anchor bolt circle
Pattern diameter and count of anchor bolts matching the pole base plate. Bolt projection, embedment, and torque must follow the pole manufacturer's drawings.
Breakaway transformer base
Frangiible pole base designed to yield on vehicle impact, reducing crash severity. Commonly required near high-speed traffic where fixed poles pose a hazard.
Pole base moment
Bending moment at the pole base equal to wind force times lever arm. It governs foundation size, anchor bolt design, and pole wall thickness selection.
Direct-buried pole
Pole set into soil without a concrete foundation, relying on embedment depth and soil resistance. Soil type, compaction, and groundwater affect overturning capacity.
Voltage drop formula
Single-phase two-wire: VD = 2 x I x R x L. Three-phase: VD = 1.732 x I x R x L. R is conductor resistance per unit length; L is one-way length.
Series lighting circuit
Constant-current loop feeding luminaires through isolation transformers. The regulator maintains current; opening the loop under load is hazardous and requires fault protection.
Photocell control
Sensor switching lighting at dusk and dawn. It typically operates a contactor coil so the contactor, not the photocell, carries full circuit current.
Inrush current
Brief high current when drivers or ballasts energize. Breakers and contactors must be sized with inrush in mind to prevent nuisance tripping on lighting circuits.
Equipment grounding conductor
Conductor bonding non-current-carrying metal parts to ground. It provides a low-impedance fault path and is required for poles and luminaires by the NEC.
Adaptive lighting controls
Networked systems that dim or schedule roadway lighting by time or traffic level. They report faults and energy use, and can reduce output during low-traffic hours.
Lockout tagout
Procedure isolating and locking energy sources before maintenance. Required for lighting circuit work; verify absence of voltage before touching conductors.
Photometric field verification
Measuring illuminance with a calibrated meter at grid points after installation. Results are compared with design criteria to confirm the system meets specification.
MUTCD temporary traffic control
Manual guidance for work-zone traffic control, including signs, cones, and flaggers. Roadway lighting maintenance near traffic must follow these layouts for worker safety.