- Luminous flux
- Total light output emitted by a source in all directions, measured in lumens (lm). Luminaire lumen output is the basis for illuminance calculations and efficacy comparisons.
- Illuminance
- Light arriving at a surface per unit area, expressed in lux (lm/m²) or footcandles. One footcandle equals about 10.76 lux. Horizontal illuminance is used for roadway design criteria.
- Luminance
- Light reflected or emitted from a surface in a given direction, measured in candela per square meter (cd/m²). Roadway luminance and its uniformity drive driver visibility and comfort.
- Coefficient of utilization
- Fraction of luminaire lamp lumens that reaches the roadway surface, depending on luminaire distribution, mounting height, geometry, and surface reflectances. Used in the lumen method.
- Light loss factor
- Product of lamp lumen depreciation, luminaire dirt depreciation, ballast or driver factor, and ambient factors. Converts initial lumens to maintained lumens for design calculations.
- Mesopic vision
- Vision state at intermediate light levels where both rod and cone photoreceptors contribute. Higher correlated color temperature sources can improve perceived brightness at equal photopic luminance.
- Veiling luminance ratio
- Ratio of maximum veiling luminance from glare to average roadway luminance. Standards cap this ratio to limit disability glare, with stricter limits at higher design speeds.
- Luminance uniformity ratio
- Ratio of maximum to minimum (or average to minimum) roadway luminance. Uniformity limits prevent alternating bright and dark patches that impair driver detection.
- IES roadway classification
- Categories such as freeway, arterial, collector, and local road that set design criteria. Higher speed and volume classifications require higher luminance and stricter uniformity.
- BUG rating
- Backlight, uplight, and glare rating system for outdoor luminaires. Local ordinances use BUG ratings to limit light trespass, skyglow, and glare.
- NEC Article 410
- National Electrical Code article covering luminaires, lamp holders, and associated equipment. It sets installation, support, and wiring requirements but does not set photometric design levels.
- Warrant analysis
- Study of roadway classification, traffic volume, pedestrian activity, and nighttime crash history to decide whether lighting is justified. Results support funding and design decisions.
- LED driver
- Power supply converting AC line voltage to regulated constant current for LED modules. Output current, forward voltage range, dimming protocol, and programming must match the luminaire.
- L70 lumen maintenance
- Projected operating hours when LED lumen output falls to 70 percent of initial. Values are extrapolated using TM-21 methods from measured LM-80 data.
- High-pressure sodium lamp
- Arc discharge source with high efficacy and warm orange light. Requires a ballast with ignitor and capacitor; its low color rendering limits use where color matters.
- Ballast factor
- Ratio of lamp lumens produced on a given ballast to lumens on a reference ballast. It scales both light output and input power in fluorescent and HID systems.
- IES distribution type
- Luminaire light pattern classification from Type I (narrow, along roadway) to Type V (symmetric). Type and cutoff classification determine spacing and glare control.
- IP rating
- Ingress protection code giving resistance to dust and water, such as IP65 or IP66. It indicates suitability of luminaire and driver enclosures for outdoor roadway environments.
- Effective projected area
- Wind-facing area of luminaire and arm, used with wind pressure to compute pole loads. Manufacturer EPA values feed structural calculations for poles and foundations.
- Anchor bolt circle
- Pattern diameter and count of anchor bolts matching the pole base plate. Bolt projection, embedment, and torque must follow the pole manufacturer's drawings.
- Breakaway transformer base
- Frangiible pole base designed to yield on vehicle impact, reducing crash severity. Commonly required near high-speed traffic where fixed poles pose a hazard.
- Pole base moment
- Bending moment at the pole base equal to wind force times lever arm. It governs foundation size, anchor bolt design, and pole wall thickness selection.
- Direct-buried pole
- Pole set into soil without a concrete foundation, relying on embedment depth and soil resistance. Soil type, compaction, and groundwater affect overturning capacity.
- Voltage drop formula
- Single-phase two-wire: VD = 2 x I x R x L. Three-phase: VD = 1.732 x I x R x L. R is conductor resistance per unit length; L is one-way length.
- Series lighting circuit
- Constant-current loop feeding luminaires through isolation transformers. The regulator maintains current; opening the loop under load is hazardous and requires fault protection.
- Photocell control
- Sensor switching lighting at dusk and dawn. It typically operates a contactor coil so the contactor, not the photocell, carries full circuit current.
- Inrush current
- Brief high current when drivers or ballasts energize. Breakers and contactors must be sized with inrush in mind to prevent nuisance tripping on lighting circuits.
- Equipment grounding conductor
- Conductor bonding non-current-carrying metal parts to ground. It provides a low-impedance fault path and is required for poles and luminaires by the NEC.
- Adaptive lighting controls
- Networked systems that dim or schedule roadway lighting by time or traffic level. They report faults and energy use, and can reduce output during low-traffic hours.
- Lockout tagout
- Procedure isolating and locking energy sources before maintenance. Required for lighting circuit work; verify absence of voltage before touching conductors.
- Photometric field verification
- Measuring illuminance with a calibrated meter at grid points after installation. Results are compared with design criteria to confirm the system meets specification.
- MUTCD temporary traffic control
- Manual guidance for work-zone traffic control, including signs, cones, and flaggers. Roadway lighting maintenance near traffic must follow these layouts for worker safety.