Odisha CHSE +2 VOC Micro Irrigation Technician flashcards
Odisha CHSE +2 VOC Micro Irrigation Technician · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Field capacity
- Water content of soil after excess water has drained by gravity, held at about -10 to -33 kPa. It is the upper limit of plant-available water and a key design reference for irrigation scheduling.
- Permanent wilting point
- Soil water content at about -1500 kPa where plants can no longer extract water and wilt permanently. The difference between field capacity and this point gives plant-available water.
- Reference evapotranspiration ETo
- Evapotranspiration from a well-watered reference grass surface, computed by FAO-56 Penman-Monteith from weather data. Crop water use is ETo multiplied by the crop coefficient Kc.
- Readily available water
- Fraction p of plant-available water that a crop can use without stress, typically 0.4 to 0.6 of the field capacity minus wilting point range. It sets the irrigation interval.
- Wetted bulb shape
- Three-dimensional wetted soil volume below an emitter. Sandy soils produce narrow deep bulbs, clay soils wide shallow bulbs, so emitter spacing and discharge must match texture.
- Pressure-compensating emitter
- Drip emitter that maintains a nearly constant discharge, usually within ten percent, over a wide pressure range of roughly 0.5 to 4 bar. It allows long laterals and level differences.
- Media filter
- Sand or gravel bed filter that removes fine organic and inorganic particles from surface water. It is backwashed when differential pressure reaches about 0.5 to 0.8 bar.
- Air release valve
- Valve installed at high points of mains and sub-mains to discharge trapped air. It prevents air locks, protects against water hammer and improves flow stability in the network.
- Emission uniformity
- Design measure of discharge variation across a drip system, calculated from emitter coefficient of variation and number of emitters per plant. Values of 90 percent or more are targeted.
- Lateral flushing velocity
- Minimum flow speed at the open lateral end, about 0.3 to 0.5 metres per second, needed to carry out accumulated sediment. Flushing is done at least fortnightly.
- Chlorination for clogging
- Injection of chlorine to control organic and bacterial clogging of drip emitters and filters. Continuous dosing uses 1 to 2 ppm free chlorine, shock treatment 50 to 100 ppm.
- Christiansen uniformity coefficient
- Uniformity measure for sprinkler systems computed from the absolute deviations of individual catch depths from the mean. Values of 80 percent or more are generally acceptable.
- Sprinkler spacing rule
- Recommended spacing of about 50 to 60 percent of wetted diameter along laterals and 40 to 50 percent between laterals. Closer spacing raises uniformity in wind.
- Wind effect on sprinklers
- Wind above about 3 metres per second distorts sprinkler patterns, causing drift and uneven distribution. Irrigating at night or reducing spacing reduces the effect.
- Best efficiency point
- Operating point on a pump curve where efficiency is highest. The duty point, where pump curve meets system curve, should lie close to this point for energy savings.
- NPSH
- Net positive suction head, the absolute pressure margin at the pump suction. Available NPSH must exceed required NPSH to prevent cavitation, noise and impeller damage.
- Venturi injector
- Fertigation device that uses a pressure drop to draw stock solution into the water line. It is cheap but causes 10 to 30 percent head loss.
- Backflow prevention
- Check valve and vacuum breaker arrangement that stops fertilizer or chemical solution from flowing back into the water source. It is mandatory for fertigation safety.
- Emitter clogging diagnosis
- Open emitters at head, middle and tail of laterals and compare discharge. Uniform low flow indicates filter or pressure problems; scattered low flow indicates clogging.
- Filter differential pressure
- Pressure difference across a filter element, measured by two gauges. A rise of about 0.5 bar signals clogging and the need to clean or backwash.
- Goof plug
- Small plug used to close an unwanted emitter hole or repair a punctured lateral. It is a standard item in a micro irrigation repair kit.
- Drip water quality limits
- Guideline values for clogging risk: EC below 1.5 dS/m is safe, pH 6.5 to 8.0, suspended solids below 50 mg/L, iron below 0.5 mg/L and manganese below 0.1 mg/L.
- Bicarbonate scaling risk
- Bicarbonate above about 2 milliequivalents per litre, or hardness above 200 mg/L as calcium carbonate, indicates calcium carbonate scaling. Acidification controls it.
- Solar pump sizing
- Pump power is calculated from water density, gravity, discharge and total head divided by pump efficiency. Solar array size must cover peak daily hydraulic energy.
- Crop coefficient Kc
- Factor that adjusts reference evapotranspiration to a specific crop and growth stage. Values rise from initial to mid-season and decline in late season.
- Tensiometer scheduling
- Scheduling method using soil matric potential readings. Irrigation is started when the tensiometer reaches a threshold, commonly -30 to -50 kPa for many horticultural crops.
- Protected cultivation ET
- Evapotranspiration inside a polyhouse or shade net, reduced by roughly 20 to 50 percent compared with open field. Irrigation scheduling must be adjusted to this microclimate.
- Per Drop More Crop subsidy
- Component of the national micro irrigation programme giving capital subsidy, typically 55 percent for small and marginal farmers and 45 percent for others, with possible state top-up.
- Payback period
- Capital cost of a micro irrigation system divided by annual net benefit. It shows how many years are needed to recover the investment from increased income or savings.
- Annual maintenance contract
- Service agreement in which the provider performs scheduled flushing, filter cleaning, chemical treatment and repairs for a fixed annual fee. It is a core micro irrigation service business.
- Electrical safety in irrigation
- Earthing of pump and controller, use of RCCB or ELCB protection, dry locked panels and never working on live circuits. Water and electricity together make this critical.
- Chemical handling safety
- Use of gloves, goggles and mask when handling acids, chlorine and fertilizers, with labelled separate storage away from water sources and immediate flushing of skin contact.