Maharashtra HSC NSQF Micro Irrigation Technician flashcards
Maharashtra HSC NSQF Micro Irrigation Technician · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Distribution uniformity (DU)
- Ratio of the average of the lowest quarter of emitter or catch-can readings to the overall mean, expressed as a percentage. Drip design target is 85% or higher.
- Emission uniformity (EU)
- Uniformity measure combining manufacturing variation and pressure differences: EU = 100 × (1 − 1.27 × CV ÷ √n), where CV is the emitter coefficient of variation and n the emitters per plant.
- Pressure-compensating emitter
- A dripper with a flexible or labyrinth membrane that keeps discharge nearly constant across roughly 0.5 to 4.0 bar, allowing long laterals and level or gently sloping blocks.
- Subsurface drip irrigation
- Drip laterals buried 15 to 30 cm below the soil surface, reducing evaporation and surface damage while requiring care against root intrusion and rodent damage.
- Field capacity
- Soil water content retained after excess water drains under gravity, roughly at −0.33 bar matric potential. It is the upper limit of water available to plants.
- Permanent wilting point
- Soil water content at about −15 bar where plants can no longer extract water and remain permanently wilted. The difference from field capacity is available water.
- Management allowed depletion
- The fraction of available soil water that may be consumed before irrigation is triggered. Typical values are 0.5 for field crops and 0.3 to 0.4 for horticulture.
- Crop evapotranspiration (ETc)
- Water lost by the crop through transpiration and soil evaporation, computed as the reference evapotranspiration ETo multiplied by the crop coefficient Kc for the growth stage.
- Tensiometer
- A sealed water-filled tube with a porous ceramic tip and vacuum gauge that reads soil matric potential directly, used to trigger irrigation near the depletion threshold.
- Total dynamic head
- The sum of static lift, friction losses in suction and delivery pipes, required system operating pressure, and elevation difference, used to select the pump duty point.
- Media sand filter
- A pressure vessel with graded sand or gravel beds that traps fine organic and inorganic particles. It is cleaned by backwashing when differential pressure rises about 0.5 to 0.7 bar.
- Venturi injector
- A fertigation device that draws stock solution through suction created by a pressure differential of about 0.3 to 0.7 bar across a converging-diverging throat. No moving parts.
- Backflow prevention
- A check valve plus vacuum breaker installed between the injection point and the water source, stopping fertiliser or chemical from contaminating the supply or drinking water.
- Screen filter mesh rating
- The number of openings per linear inch of screen. Drip systems generally need 120 to 200 mesh, while micro-sprinklers can accept coarser 80 to 100 mesh filtration.
- Hazen-Williams equation
- An empirical pipe friction formula relating head loss to flow, pipe diameter, length, and a roughness coefficient C. It is used to size laterals, sub-mains, and mainlines.
- Christiansen uniformity coefficient
- A catch-can uniformity measure: CU = 100 × (1 − sum of absolute deviations from the mean ÷ total catch). Sprinkler designs target 80% or higher.
- Allowable pressure variation
- The pressure difference along a lateral or sub-main that keeps flow variation within about 10 percent, roughly a 20 percent pressure variation for non-compensating emitters.
- Basic soil intake rate
- The steady infiltration rate of a soil. Sprinkler application rate must stay below it to avoid ponding and runoff, especially on clay soils with low intake.
- Flush valve
- A valve fitted at the far end of laterals and sub-mains to discharge sediment and debris during routine flushing. It must be opened before commissioning and periodically thereafter.
- Pressure test
- A commissioning check that pressurises the network to 1.5 times design working pressure, or the pipe rated test pressure, and holds it to detect leaks at joints and fittings.
- Catch-can test
- A sprinkler field test using cans on a grid within the spacing, run for a set time, with depths measured to compute the uniformity coefficient and application rate.
- Chlorination of drip lines
- Injection of chlorine to about 1 to 2 ppm free chlorine to dissolve organic and bacterial clogging in laterals and emitters, followed by flushing with clean water.
- Differential pressure clogging signal
- A rise of about 0.5 to 0.7 bar across a filter indicates clogging. Backwash first, then inspect and clean or replace the screen or disc element.
- Acid injection for scale
- Controlled injection of acid to dissolve calcium carbonate scale in emitters and lines, always adding acid to water and flushing afterwards to protect the crop.
- Pump cavitation symptoms
- Noise, vibration, and falling discharge caused by vapour bubbles collapsing at the impeller, usually from a clogged suction strainer, air leak, or excessive suction lift.
- Electrical safety at pump panel
- Working earth connection, ELCB or RCCB protection, and an isolator at every pump panel. Isolate the supply before opening the panel or touching a wet pump.
- Confined space entry rule
- Sumps, tanks, and borewell pits require gas testing, a harness, and a standby observer outside. Entry alone is prohibited regardless of the task duration.
- Acid handling rule
- Always add acid slowly to water, never water to acid, while wearing gloves, goggles, and a face shield, with an eye-flush water source kept nearby.
- Emitter count per hectare
- Computed as 10,000 square metres divided by the product of row spacing and emitter spacing in metres, giving the number of drippers used for bottom-up costing.
- Subsidy documentation set
- Land records, soil and water test reports, layout drawing, quotation from an empanelled supplier, and beneficiary bank and identity details, submitted for micro irrigation subsidy.
- Job card
- A field record listing farmer details, survey number, crop, area, materials issued, labour hours, commissioning readings, and the farmer's signature on completion.
- As-built drawing
- A post-installation layout showing field boundary, blocks, mainline and sub-main routes, lateral spacing, valve numbers, and headworks location with scale and north arrow.