Ohm's law
Current through a conductor is directly proportional to the voltage across it and inversely proportional to its resistance, giving V = I × R at constant temperature.
Electrical power formula
Power in watts equals voltage multiplied by current, P = V × I, and can also be written as I²R or V²/R for resistive loads.
Series circuit rule
In a series circuit the same current flows through every component, the total resistance is the sum of the resistances, and the supply voltage divides across them.
Parallel circuit rule
In a parallel circuit every branch has the same voltage, the branch currents add, and the total resistance is less than the smallest individual resistance.
Nichrome heating element
A nickel-chromium alloy with high resistivity, high melting point and resistance to oxidation at red heat, making it the standard material for heater elements.
Mica as insulator
A mineral insulator that withstands high temperature and has good dielectric strength, so it is used as a sheet between the element and the soleplate of irons.
Lockout and tagout
A safety procedure in which the supply is isolated, the fuse removed or breaker locked, a warning tag fixed, and the circuit proved dead before work begins.
Electrical fire extinguisher
Carbon dioxide or dry powder extinguishers are used on live electrical fires because they do not conduct; water and foam must never be used.
Conduit wiring
A wiring system in which insulated conductors are drawn through PVC or steel pipes fixed on or inside a wall, giving mechanical protection and, with steel, earth continuity.
Two-way switch
A three-terminal switch with one common and two way contacts, wired in pairs so a lamp can be controlled from two different positions.
Earth pin of a socket
The earth pin is longer and thicker than the live and neutral pins so the earth connection makes first and breaks last when a plug is inserted or removed.
Automatic iron thermostat
A bimetallic strip inside the iron bends as it heats and opens the element contacts at the set temperature, closing them again on cooling to hold the heat steady.
Universal motor
A series-wound motor with brushes and a commutator that runs on either AC or DC, giving high speed and high starting torque for mixers and drills.
Capacitor-start motor
A single-phase induction motor whose auxiliary winding is fed through a large capacitor to create starting torque; a centrifugal switch disconnects it near running speed.
Ceiling fan capacitor fault
If the run capacitor loses capacitance the fan hums without turning or needs a push to start, because the auxiliary winding no longer produces enough phase shift.
MCB function
A resettable miniature circuit breaker that trips on overload by thermal action and on short circuit by magnetic action, protecting wiring in the phase conductor.
RCCB 30 mA
A current-operated earth leakage device that trips when the phase and neutral currents differ by about 30 mA, the level chosen to protect people from fatal shock.
Purpose of earthing
Earthing connects metal appliance bodies to the ground so a fault current flows and trips the protective device, keeping the body at safe potential.
Earth continuity test
A dead test using a multimeter or ohmmeter between the appliance metal body and the earth pin, expected to read close to zero ohms.
Megger insulation test
A test applying 500 V DC between live parts and the metal body; a sound appliance shows insulation resistance above one megohm.
Open circuit fault
A break in the conductor path, such as a burnt element or broken wire, shown by infinite resistance and a completely dead appliance.
BEE star rating
An Indian label from one to five stars showing the energy efficiency of an appliance, with five stars the most efficient and annual consumption stated in kWh.
Energy efficiency formula
Efficiency equals useful output energy divided by total input energy, multiplied by one hundred and expressed as a percentage; losses appear mainly as heat.
Resistance of a conductor
Resistance equals resistivity times length divided by cross-sectional area, so a longer or thinner wire has more resistance than a short thick one.
Fuse wire material
A tin-lead alloy with a low melting point, chosen so the fuse melts and breaks the circuit before the wiring or appliance winding overheats.
Insulated hand tools
Tools with moulded insulation on the handles, rated for a stated voltage such as 1000 V, used to reduce shock risk during electrical work.
Wire gauge selection
Conductor size is chosen from the load current and permitted voltage drop: about 1.0 mm² for lighting, 1.5 to 2.5 mm² for socket circuits.
Loop-in wiring system
A wiring method in which the supply and switched wires are looped through the ceiling rose, so the switch drop cable runs from rose to switch.
Geyser thermal cut-out
A one-shot safety device that opens the element circuit permanently if the thermostat fails and water temperature exceeds a safe limit.
Thermal relay protection
A bimetal or heater-operated relay in a motor circuit that opens the contactor when sustained overload current raises winding temperature above a safe value.
Short circuit fault
An unintended low-resistance path between phase and neutral or phase and earth, causing very large current that blows the fuse or trips the breaker at once.
Standby power loss
Small continuous consumption by appliances left in standby mode, avoided by switching off at the socket or using a master switch strip.