Week 1

Electrical Circuits and Network Theory & Electrical Machines (Transformers, DC, Induction and Synchronous Machines)

  • Apply Kirchhoff's laws, mesh and nodal analysis to DC resistive networks containing independent and dependent sources, working 15 problems by hand.

  • Reduce multi-source networks with Thevenin, Norton, superposition and maximum power transfer theorems and verify each result by a second method.

  • Compute series and parallel RLC resonance frequency, bandwidth, Q-factor and power factor correction capacitance for single-phase AC circuits.

  • Calculate star/delta line and phase voltages, currents and three-phase power using √3·V_L·I_L·cosφ for balanced and unbalanced loads.

  • Derive the transformer EMF equation E = 4.44·f·N·Φ_max and relate turns ratio to voltage, current and reflected impedance.

Your checkpoint

A 30-question timed test covering network theorems, three-phase circuits and transformer fundamentals, scored and corrected to at least 65% with every wrong answer rewritten correctly.

Week 2

Electrical Machines (Transformers, DC, Induction and Synchronous Machines)

  • Interpret open-circuit and short-circuit test data to build the transformer equivalent circuit and compute regulation and efficiency at full, half and 25% load.

  • Evaluate transformer parallel-operation conditions, tap-changer operation, autotransformer savings and three-phase connection groups (Yy, Yd, Dy, Dd).

  • Derive the DC generator EMF equation and compare lap and wave windings for voltage and current rating.

  • Sketch and explain the load characteristics of shunt, series and compound DC generators and motors, including commutation and armature reaction effects.

  • Solve DC shunt motor speed-control numericals (armature voltage, field flux, armature resistance) and compute starter resistance steps for a three-point starter.

Your checkpoint

A handwritten one-page formula sheet per domain plus 20 fully solved numericals on transformer testing and DC machine characteristics, checked against a self-made answer key.

Week 3

Electrical Machines (Transformers, DC, Induction and Synchronous Machines)

  • Compute slip, rotor frequency, developed torque, maximum torque and efficiency from the equivalent circuit of a three-phase induction motor.

  • Compare direct-on-line, star-delta, autotransformer and rotor-resistance starting by starting current ratio, starting torque and permitted starting duration.

  • Draw phasor diagrams for a salient and non-salient alternator to show how excitation and load angle change terminal voltage, and compute voltage regulation by EMF and MMF methods.

  • Explain V-curves, damper windings and synchronous-motor starting, then state where a synchronous condenser is preferred for power factor correction.

  • Distinguish split-phase, capacitor-start, capacitor-run and shaded-pole single-phase motors by starting torque, efficiency and typical application.

Your checkpoint

A one-page comparison matrix of induction versus synchronous machines plus 25 solved numericals on slip, torque, starting current and alternator regulation.

Week 4

Power Systems (Generation, Transmission, Distribution and Protection)

  • Compare thermal, hydro and nuclear plant layouts and auxiliaries, then compute load factor, diversity factor, plant capacity factor and a two-part tariff bill.

  • Calculate sag and tension for overhead lines at equal and unequal tower heights, including ice and wind loading effects.

  • Compute inductance and capacitance of single-phase and three-phase line configurations and quantify the effect of conductor bundling and transposition.

  • Model short, medium (nominal-π and nominal-T) and long transmission lines, then compute sending-end voltage, regulation and line efficiency.

  • Explain corona formation, critical disruptive voltage and the methods used to reduce corona loss.

Your checkpoint

A 40-mark sectional test on generation economics and transmission-line performance, reviewed with a written error log listing each mistake and its correct method.

Week 5

Power Systems (Generation, Transmission, Distribution and Protection)

  • Compute voltage drop and power loss in radial and ring distributors carrying concentrated and uniformly distributed loads.

  • Select cable size and derate current rating for ambient temperature, grouping, depth of laying and soil thermal resistivity.

  • Determine CT ratio, plug setting and time multiplier setting for a three-stage overcurrent and earth-fault relay scheme, and explain directional and distance relay zones.

  • Analyse Merz-Price differential protection for transformer and generator, Buchholz relay operation and restricted earth-fault protection.

  • Describe arc-quenching principles in oil, air-blast, SF6 and vacuum circuit breakers and match each breaker type to a voltage class.

Your checkpoint

A relay-setting calculation worksheet for a three-stage overcurrent scheme plus 15 distribution voltage-drop problems solved with assumptions stated.

Week 6

Power Electronics and Electric Drives & Measurements and Instrumentation

  • Derive average and RMS output voltage, ripple factor and input power factor for single-phase and three-phase controlled rectifiers feeding R and RL loads.

  • Compute duty cycle and current ripple for buck, boost and buck-boost choppers to reach a target output voltage.

  • Explain V/f control and PWM inverter operation in induction-motor drives, and distinguish constant-torque from constant-power load duty.

  • Select PMMC versus moving-iron instruments for AC and DC measurement, and compute wattmeter, energy-meter and CT/PT ratio errors.

  • Explain Wheatstone, Maxwell and Schering bridges and state which bridge measures resistance, inductance and capacitance respectively.

Your checkpoint

A 30-question mixed quiz on converters, drives and instrumentation, scored to at least 65%, supported by a one-page formula card.

Week 7

Basic and Digital Electronics & Control Systems

  • Analyse diode, BJT and MOSFET bias circuits, then compute quiescent point, mid-band gain and input/output impedance of a CE amplifier.

  • Convert between binary, octal, hexadecimal and BCD, and simplify Boolean expressions with K-maps before implementing them using only NAND or NOR gates.

  • Design combinational circuits using adders, multiplexers and decoders, and explain flip-flop, counter and shift-register operation with timing waveforms.

  • Derive transfer functions and evaluate rise time, peak overshoot and settling time for first- and second-order systems.

  • Apply Routh-Hurwitz, root-locus and Bode-plot criteria to judge stability and read gain and phase margins.

Your checkpoint

A closed-book 40-minute test on digital logic and control-system stability, scored to at least 70%, with all skipped questions reworked.

Week 8

Electrical Installation, Wiring, Estimation and Safety Practices & Renewable Energy and Energy Conservation & General Awareness, Reasoning and Language (Gujarati/English)

  • Compute connected load, cable size, MCB/fuse rating and plate or pipe earthing requirements for one domestic and one small industrial wiring layout.

  • Apply Indian Electricity Rules and safety practice to earthing resistance limits, RCCB/ELCB selection, permit-to-work and first aid for electric shock.

  • Estimate conduit, wire, switch and accessory quantities for a given wiring layout and prepare a material and cost sheet.

  • Compare grid-tied and off-grid solar PV, wind and biomass systems, then compute annual energy saving, payback period and bulb/fan replacement savings.

  • Attempt a full-length mock covering quantitative aptitude, reasoning and Gujarati/English grammar, and analyse section-wise accuracy.

Your checkpoint

A full-length 100-question mock completed in exam timing, with section-wise score analysis and a ranked list of the ten weakest areas to revise before the exam.

Milestones

Week 2: Solve the 20 transformer and DC-machine numericals with at least 70% accuracy and write the EMF, torque, regulation and efficiency formulas from memory in under 10 minutes.

Week 4: Score at least 65% on the Domains 1-3 sectional test and reproduce all network, machine and transmission-line formulas unaided.

Week 6: Score at least 65% on the power electronics and instrumentation quiz, with both Domain 4 and Domain 5 formula cards completed.

Week 8: Score at least 60% overall on the full-length mock with no section below 50%, and hold a written revision list of remaining weak areas.