NFSC Sub-Officer Entrance study materials
NFSC Sub-Officer Entrance study resources

NFSC Sub-Officer Entrance key terms

NFSC Sub-Officer Entrance · Get comfortable with the vocabulary.

Flashover

The sudden transition in a compartment fire where all exposed combustible surfaces ignite almost simultaneously, producing a room fully involved in flame and a rapid, steep rise in temperature.

Related: Backdraught, Pyrolysis, Fire Triangle
Backdraught

A sudden explosion-like ignition of accumulated hot gases when air is admitted to a fire in a poorly ventilated, oxygen-starved compartment, driving flame out of the openings.

Related: Flashover, Smoke Explosion, Fire Triangle
Pyrolysis

Chemical decomposition of a solid fuel by heat in the absence of oxygen, releasing flammable gases and vapours that then burn in the flame zone.

Related: Flashover, Fire Triangle
Fire Triangle

The three elements needed for combustion: fuel, oxygen and heat. Removing any one of them extinguishes or prevents fire, and the model underlies most extinguishing methods.

Related: Fire Tetrahedron, Pyrolysis
Fire Tetrahedron

An extension of the fire triangle adding the chemical chain reaction as a fourth element, used to explain why chemical extinguishing agents such as dry powder stop flaming combustion.

Related: Fire Triangle, Vapour Blanket
Vapour Blanket

A layer of foam, gas or vapour held over a liquid fuel surface that separates the fuel from oxygen and suppresses the release of flammable vapour.

Related: Fire Tetrahedron, Flash Point
Flash Point

The lowest temperature at which a liquid gives off enough vapour to form an ignitable mixture with air near its surface, without the vapour continuing to burn.

Related: Fire Point, Flammable Range, Vapour Blanket
Fire Point

The temperature slightly above the flash point at which a liquid releases vapour fast enough to sustain continuous burning once ignited.

Related: Flash Point, Flammable Range
Flammable Range

The range between the lower and upper concentration limits of fuel vapour in air within which ignition can occur; outside this band the mixture is too lean or too rich to burn.

Related: Flash Point, Vapour Density
Vapour Density

The mass of a vapour or gas compared with an equal volume of air. Values above one mean the vapour is heavier than air and tends to collect in low-lying areas.

Related: Flammable Range, Flash Point
Smoke Explosion

Rapid ignition of a pre-mixed cloud of unburnt smoke and air inside a compartment, producing a pressure wave without the inflow of fresh air that characterises a backdraught.

Related: Backdraught, Flashover
Burning Rate

The speed at which a material loses mass or releases heat per unit area per unit time while burning, used to estimate fire growth and required extinguishing application rates.

Related: Fire Load, Heat Release Rate
Heat Release Rate

The rate at which a fire liberates thermal energy, usually expressed in kilowatts or megawatts, and the main measure of fire size and growth potential.

Related: Burning Rate, Fire Load
Fire Load

The total heat energy that could be released by burning all combustible contents and linings within a compartment, usually expressed per unit floor area.

Related: Burning Rate, Compartmentation
Compartmentation

Dividing a building into fire-resisting compartments by walls, floors and doors so that fire and smoke are held in the area of origin for a defined period.

Related: Fire Load, Fire Door
Fire Door

A door assembly with a stated fire resistance rating, fitted with self-closing and intumescent or smoke-sealing devices, that maintains the integrity of a compartment wall when closed.

Related: Compartmentation, Fire Resistance Rating
Fire Resistance Rating

The period in minutes or hours for which a structural element or assembly resists fire under test, judged on stability, integrity and insulation criteria.

Related: Compartmentation, Fire Door
Dead Load

The permanent, static weight of a structure itself, including walls, floors, roofs and fixed services, that the building must always carry.

Related: Live Load, Structural Collapse Zone
Live Load

The variable weight imposed on a structure by occupants, furniture, stored goods and movable equipment, which changes over time and is allowed for in design.

Related: Dead Load
Structural Collapse Zone

The ground area around a damaged building where debris could fall or walls could topple, calculated as a distance at least equal to the structure's height.

Related: Dead Load, Shoring
Shoring

Temporary timber, steel or pneumatic props placed to support weakened walls, floors or trenches during rescue work to protect casualties and rescuers.

Related: Structural Collapse Zone, Trench Rescue
Trench Rescue

The specialised operation of freeing a person trapped in an excavated trench, requiring collapse protection, shoring and avoidance of loading the sides.

Related: Shoring, Structural Collapse Zone
Extrication

The process of releasing and removing a trapped casualty from a vehicle, structure or machinery using hydraulic, pneumatic or manual cutting and spreading tools.

Related: Trench Rescue, Shoring
Water Hammer

A pressure surge caused by a sudden change in water velocity in a pipe or hose, producing a loud knock and possible damage to fittings and appliances.

Related: Hydrant, Delivery Hose
Hydrant

A valved connection on a water main, above or below ground, from which firefighting crews draw water into pumps or appliances through hose.

Related: Water Hammer, Delivery Hose
Delivery Hose

A flexible hose that carries water from a pump or appliance to a branch or nozzle under pressure, as distinct from a suction hose.

Related: Water Hammer, Hydrant
Jet vs Fog

Two nozzle settings: a solid jet throws water far and penetrates deep-seated fire, while a spray or fog pattern absorbs heat, protects crews and disperses vapour clouds.

Related: Water Hammer, Ventilation
Ventilation

The controlled release of heat, smoke and hot gases from a compartment by opening or cutting openings, improving visibility and reducing the risk of flashover or backdraught.

Related: Flashover, Backdraught, Jet vs Fog
Sprinkler System

A fixed piping network with heat-actuated heads that automatically discharge water onto a fire, controlling or extinguishing it before crews arrive.

Related: Compartmentation, Fire Load
Wet Riser

A vertical pipe installed in a building, kept charged with water and fitted with landing valves so crews can connect hose on upper floors without long hose runs.

Related: Hydrant, Delivery Hose
Bunding

A low wall or embankment around a storage tank or drum area that contains spilled liquid and firefighting water, preventing it from spreading to drains or other risks.

Related: Flash Point, Vapour Density
Hazchem Code

A three-character emergency action code on vehicles and containers carrying dangerous goods, telling responders which extinguishing medium and protective measures to use.

Related: Flash Point, Bunding
UN Number

A four-digit identification number assigned to a dangerous good or article, marked on packages and transport documents to identify the substance quickly in an emergency.

Related: Hazchem Code, Flash Point
Pressure

Force acting per unit area, measured in pascals; in fire service work it explains nozzle reaction, hose friction loss and the lift available from a pump.

Related: Water Hammer, Delivery Hose
Specific Heat Capacity

The heat energy needed to raise the temperature of one kilogram of a substance by one kelvin, explaining why water absorbs large amounts of heat when extinguishing fire.

Related: Latent Heat of Vaporisation, Fire Tetrahedron
Latent Heat of Vaporisation

The energy absorbed when a liquid changes to vapour at its boiling point without a temperature change; water's high value makes steam production a powerful cooling mechanism.

Related: Specific Heat Capacity, Fire Tetrahedron
Inference

A conclusion drawn from stated evidence rather than stated directly; comprehension questions often ask what can be reasonably inferred from a passage.