Punjab PSEB Matric NSQF Telecom (Optical Fiber Splicer) flashcards
Punjab PSEB Matric NSQF Telecom (Optical Fiber Splicer) · Build recall with a focused review session.
34 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Critical angle
- The minimum incidence angle at which light in the core is totally internally reflected at the core-cladding boundary; it exists only when the core index exceeds the cladding index.
- Numerical aperture
- NA = sqrt(n1 squared minus n2 squared). It sets the acceptance cone of the fibre, so a higher NA couples more light but supports more modes.
- V-number
- V = (2 pi a / lambda) times NA. When V is below about 2.405 the fibre supports only the fundamental mode and behaves as single-mode at that wavelength.
- Decibel formula
- Attenuation in decibels equals ten times the base-10 logarithm of input power divided by output power; loss per kilometre is that value divided by fibre length.
- TIA-598 12-fibre colour code
- Blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, aqua. The same sequence numbers buffer tubes and repeats with tracers beyond twelve.
- Single-mode jacket colour
- Yellow jacket marks single-mode OS1 or OS2 cable with a 9 micrometre core, used at 1310 and 1550 nanometres for long distances.
- Multimode jacket colours
- Orange marks OM1 and OM2, aqua marks OM3 and OM4, and lime green marks OM5; all are used with 850 nanometre sources over short reaches.
- Loose-tube versus tight-buffer
- Loose-tube cable houses fibres in gel-filled tubes for outdoor duct and aerial routes; tight-buffered cable places coating directly on the fibre for indoor riser and patch use.
- Cleaver end-face quality
- An acceptable cleave has an angle of 0.5 degrees or less with no hackle, lip or mist; the splicer end-face viewer confirms it before arc fusion.
- Visual fault locator use
- A red laser injected into the fibre glows at breaks, tight bends and damaged connectors within a few kilometres, giving a quick location before OTDR testing.
- Mandrel wrap live-fibre check
- Five turns of fibre around a 25 or 30 millimetre mandrel strip enough light at 1310 and 1550 nanometres for a power meter to confirm the fibre is not live.
- Connector inspection scope
- A 200x or 400x magnifier used to inspect connector end faces for dust, scratches and residue before mating, preventing permanent damage and high loss.
- Coating strip length
- Bare glass of roughly 30 to 40 millimetres is exposed, then cleaved to the splicer's specified bare-fibre length, commonly 8 to 16 millimetres.
- Buffer tube gel cleaning
- Gel is wiped from exposed fibres with lint-free wipes and 99 percent isopropyl alcohol; dry tissue alone leaves residue that causes bubbles and high splice loss.
- Fibre scrap handling
- Bare glass offcuts go into a rigid sealed scrap container immediately, never on the floor or clothing, because splinters are nearly invisible and penetrate skin.
- Arc calibration check
- An arc check is run before each splicing session and after electrode changes, altitude or humidity shifts, because arc power drifts and affects splice quality.
- Good fusion splice loss
- A single-mode fusion splice should measure about 0.05 decibels or less; a splicer estimate above roughly 0.1 decibels is rejected and re-spliced.
- Mechanical splice loss
- A mechanical splice aligns cleaved fibres in a precision sleeve with index-matching gel and typically gives 0.1 to 0.3 decibels, useful where no power is available.
- Splice protector placement
- The heat-shrink protector with its steel strength rod is centred over the bare fibre and fully shrunk in the oven, then cooled before loading into the tray.
- Bidirectional OTDR testing
- Splice loss is measured from both ends and averaged, because differing backscatter coefficients on the two fibres make single-direction readings inaccurate.
- OTDR dead zone
- The event dead zone is about one metre and the attenuation dead zone about four metres; launch and receive fibres are added to resolve short links.
- Power meter reference method
- The reference is set with the same connectors, launch cords and wavelength as the link under test, then the link is inserted and loss read directly.
- Test wavelengths
- Single-mode links are tested at 1310 and 1550 nanometres, multimode at 850 and 1300 nanometres, and a link must pass at every specified wavelength.
- Closure IP68 rating
- IP68 means dust-tight and protected against water immersion under stated conditions, required for buried and manhole splice closures exposed to standing water.
- Splice tray bend radius
- Fibres inside a splice tray and closure must be routed at a minimum bend radius of about 30 millimetres to avoid macrobending loss and long-term damage.
- Closure earthing bond
- The cable's metallic strength member and armour are clamped and bonded to earth through the closure, keeping the screen continuous across the joint.
- GPON downstream rates
- GPON carries 2.488 gigabits per second downstream at 1490 nanometres and 1.244 gigabits per second upstream at 1310 nanometres over a passive split tree.
- Splitter loss rule
- Splitter loss is about ten times the base-10 logarithm of the split ratio plus excess loss, so a 1:32 splitter contributes roughly 16.5 decibels.
- ONT ranging
- The OLT measures each ONT's round-trip delay and assigns an equalisation delay so all upstream bursts arrive aligned in their granted time slots.
- Optical power budget
- Total loss of fibre attenuation, splices, connectors and splitters must stay below the class budget, about 28 decibels for class B+ GPON.
- Invisible laser hazard
- 1310 and 1550 nanometre light is invisible and focuses on the retina; never view a fibre end or connector directly, and use only filtered indirect scopes.
- Manhole gas testing
- Before entry, test for oxygen, combustible gas, hydrogen sulphide and carbon monoxide, then ventilate continuously with a standby person and harness at the surface.
- Splice schedule record
- A document listing closure ID, cable IDs, fibre numbers spliced, tray assignment and measured loss, which must match the as-built records at handover.
- Splicing quotation basis
- Price equals splices times rate plus materials, testing and travel, with applicable tax; testing and OTDR reports are quoted as separate line items.