RRB JE CBT 2 - Electronics study materials
RRB JE CBT 2 - Electronics study resources

RRB JE CBT 2 - Electronics: Measurements and Instrumentation

RRB JE CBT 2 - Electronics · Work through your exam, one topic at a time.

All guide sections

Measurements and Instrumentation

What this domain tests

This section tests instrument construction and application: PMMC and moving-iron meters, shunts and multipliers, bridges, CRO operation, digital meters, transducers, and measurement error. Expect practical range-extension and bridge-balance calculations.

Core concepts

  • A PMMC meter responds to average current and works only on DC unless a rectifier is added. A moving-iron meter responds to RMS and can measure AC or DC.
  • A shunt extends current range: Rsh = ImRm/(I - Im). A series multiplier extends voltage range: Rm = (V/Im) - Rmeter.
  • Wheatstone bridge measures resistance; Maxwell bridge measures inductance; Wien bridge measures frequency or capacitance. Balance occurs when the detector current is zero.
  • A CRO displays voltage versus time. The timebase setting gives period; vertical scale gives amplitude. Probes may have 10× attenuation.
  • Accuracy is closeness to true value; precision is repeatability. Loading effect occurs when an instrument draws current from the circuit.

Worked example

A PMMC meter has full-scale current 1 mA and resistance 100 ohm. To extend its range to 10 mA, the shunt carries 9 mA at full scale. Rsh = ImRm/(I - Im) = (1 mA × 100 ohm)/9 mA = 11.11 ohm.

Traps

Do not use a PMMC meter directly on AC without a rectifier. Remember that a 10× probe divides the displayed voltage by 10 before the scope input. Bridge balance is a null condition, not a maximum reading. Avoid confusing accuracy with precision.

Key points

  • PMMC: average/Dc; moving iron: RMS.
  • Shunt extends current range.
  • Multiplier extends voltage range.
  • Wheatstone bridge measures resistance.
  • CRO timebase gives period; vertical scale gives voltage.