TSGENCO AE key terms
TSGENCO AE · Get comfortable with the vocabulary.
- Load Factor
- Related: Diversity Factor, Plant Capacity Factor
The ratio of average load over a period to the maximum demand during that period. A high value means plant capacity is used steadily rather than sitting idle most of the day.
- Diversity Factor
- Related: Load Factor
The ratio of the sum of individual maximum demands of consumers to the maximum demand on the station. It is always greater than one because consumers peak at different times.
- Skin Effect
- Related: Ferranti Effect, Corona Discharge
The tendency of alternating current to concentrate near the surface of a conductor, raising effective resistance as frequency increases. It is negligible at DC and low frequencies but significant in thick conductors at power frequencies.
- Ferranti Effect
- Related: Surge Impedance Loading, Skin Effect
The rise of receiving-end voltage above sending-end voltage on a long lightly loaded transmission line, caused by the line's shunt capacitance charging current flowing through its series inductance.
- Surge Impedance Loading
- Related: Ferranti Effect
The load at which a lossless line's reactive power generation exactly balances its reactive power absorption, numerically equal to the square of receiving voltage divided by surge impedance.
- Corona Discharge
- Related: Skin Effect
Ionisation of air around a high-voltage conductor when the surface voltage gradient exceeds the breakdown strength of air, producing hissing, ozone smell, power loss and radio interference.
- Equal Area Criterion
- Related: Critical Clearing Angle
A graphical stability test in which the accelerating area between the power-angle curve and the mechanical input must be matched by a decelerating area for the generator to remain in synchronism after a disturbance.
- Critical Clearing Angle
- Related: Equal Area Criterion
The largest rotor angle at which a fault may be cleared while the generator still regains synchronism. Clearing faster than the corresponding critical clearing time preserves stability.
- Slip
- Related: Torque-Slip Characteristic, Synchronous Speed
The fractional difference between synchronous speed and actual rotor speed of an induction machine, expressed as s = (Ns - Nr)/Ns. It is one at standstill and near zero at no load.
- Torque-Slip Characteristic
- Related: Slip, Synchronous Speed
The curve relating electromagnetic torque of an induction motor to slip, showing a stable low-slip region, a maximum torque at the breakdown slip, and a high-slip starting region.
- Synchronous Speed
- Related: Slip
The speed of the rotating magnetic field, given by 120 times frequency divided by number of poles. It is the speed at which a synchronous machine runs in steady state.
- Voltage Regulation
- Related: Parallel Operation of Transformers
The rise in secondary terminal voltage when full load is removed at a given power factor, expressed as a percentage of rated voltage. It indicates how well a transformer or alternator holds its voltage.
- Parallel Operation of Transformers
- Related: Voltage Regulation
Connecting transformers to share a load, requiring matching polarity, voltage ratio, per-unit impedance and vector group. Mismatched impedance causes unequal load sharing and circulating currents.
- Commutation
- Related: Armature Reaction
The process in a DC machine by which the direction of current in a coil reverses as it passes the brush axis. Poor commutation causes sparking at the brushes and limits machine output.
- Armature Reaction
- Related: Commutation
The distortion of the main field flux by the magnetic field set up by armature current. It shifts the magnetic neutral axis and affects voltage regulation and commutation.
- Duty Cycle
- Related: Chopper, Pulse Width Modulation
The fraction of each switching period during which a power semiconductor device conducts. In a buck converter the output voltage equals input voltage multiplied by duty cycle.
- Chopper
- Related: Duty Cycle
A static circuit that converts fixed DC input voltage into a variable DC output voltage by rapidly switching a semiconductor device on and off, controlled through the duty cycle.
- Pulse Width Modulation
- Related: Duty Cycle, Harmonic Distortion
A switching technique that synthesises a variable output voltage by varying the width of fixed-frequency pulses, widely used in inverters to control voltage and reduce low-order harmonics.
- Harmonic Distortion
- Related: Pulse Width Modulation
The presence of voltage or current components at integer multiples of the fundamental frequency, caused by non-linear loads and power electronic converters. Total harmonic distortion quantifies its severity.
- Line Commutation
- Related: Chopper
Turn-off of a thyristor in a naturally commutated converter that relies on the AC supply voltage reversing to reduce the device current to zero, unlike forced commutation in DC circuits.
- Instrument Transformer
- Related: Potential Transformer, Current Transformer Burden
A current or voltage transformer that scales high line quantities down to safe measurable values for meters and relays while isolating the instrument from the high-voltage circuit.
- Potential Transformer
- Related: Instrument Transformer
A voltage transformer connected in parallel with the circuit whose secondary provides a standard low voltage proportional to the primary voltage for measurement and protection relays.
- Current Transformer Burden
- Related: Instrument Transformer
The total impedance of the secondary circuit, including relays, meters and leads, that a current transformer must drive at rated current. Excessive burden causes ratio and phase errors.
- Wheatstone Bridge
- Related: Instrument Transformer
A four-arm resistive network used to measure an unknown resistance by balancing the bridge so that no current flows through the galvanometer connected across its centre.
- Rankine Cycle
- Related: Regenerative Feed Heating, Reheat Cycle, Condenser Vacuum
The ideal thermodynamic cycle for steam power plants, consisting of isentropic pumping, constant-pressure heat addition in the boiler, isentropic expansion in the turbine and constant-pressure heat rejection in the condenser.
- Reheat Cycle
- Related: Rankine Cycle
A steam cycle in which steam is expanded partway in the turbine, returned to the boiler for reheating at constant pressure, then expanded further, raising efficiency and limiting blade moisture.
- Regenerative Feed Heating
- Related: Rankine Cycle
Bleeding part of the steam from turbine stages to heat boiler feedwater, raising the cycle's mean temperature of heat addition and thereby improving thermal efficiency.
- Condenser Vacuum
- Related: Rankine Cycle
The sub-atmospheric pressure maintained in a steam condenser by removing air and cooling the exhaust steam, which lowers turbine exhaust pressure and increases work output.
- Specific Speed of a Turbine
- Related: Cavitation, Hydraulic Jump
A dimensionless index giving the speed at which a geometrically similar turbine would run while developing unit power under unit head. It determines whether a Pelton, Francis or Kaplan type suits a site.
- Cavitation
- Related: Specific Speed of a Turbine, Net Positive Suction Head
Formation and collapse of vapour bubbles in a liquid where local pressure falls below vapour pressure, causing noise, loss of efficiency and pitting damage to pump and turbine surfaces.
- Net Positive Suction Head
- Related: Cavitation
The absolute pressure margin above vapour pressure available at a pump suction, expressed in metres of liquid. Insufficient NPSH leads to cavitation in the pump.
- Hydraulic Jump
- Related: Specific Speed of a Turbine
An abrupt rise in water surface when flow changes from supercritical to subcritical, dissipating large amounts of energy. It is deliberately created below spillways to protect structures.
- Bearing Capacity
- Related: Liquefaction
The maximum pressure a soil mass can carry at the base of a foundation without shear failure or excessive settlement. It governs footing size and is found from field tests or theory.
- Liquefaction
- Related: Bearing Capacity
Loss of shear strength in saturated loose sands when earthquake shaking raises pore water pressure until effective stress approaches zero, causing foundations to sink or float.
- Limit State Design
- Related: Bearing Capacity
A structural design philosophy that checks separate collapse and serviceability requirements using partial safety factors on loads and material strengths instead of a single global factor.
- Data Sufficiency in Reasoning
- Related: Blood Relation Reasoning
A question type where the candidate decides whether the given statements alone are enough to answer a question, without actually computing the final value.
- Blood Relation Reasoning
- Related: Data Sufficiency in Reasoning
Puzzles that present family relationships through coded statements or a chain of relations, requiring the candidate to deduce how two named persons are related.
- Kaleshwaram Lift Irrigation Project
- Related: Godavari Water Dispute
A large multi-stage lift irrigation scheme on the Godavari in Telangana, drawing water at Medigadda and lifting it through pump houses and reservoirs to serve command areas across several districts.
- Godavari Water Dispute
- Related: Kaleshwaram Lift Irrigation Project
The long-running disagreement among riparian states over sharing Godavari waters, addressed through tribunal awards and inter-state agreements that shape Telangana's irrigation planning.