Question 1Basic Electrical Fundamentals and Safety
In a domestic wiring circuit, which conductor colour is used for the earth (protective) wire according to Indian practice?
- Green Correct answer.
- Yellow
- Black
- Red
Explanation
Indian domestic wiring uses green (or green with yellow stripes) exclusively for the protective earth conductor so that it can never be confused with a live or neutral line. Red, yellow and blue are used for phases and black for neutral. The earth wire carries no current in normal operation and exists only to give fault current a low-resistance path.
Question 2Basic Electrical Fundamentals and Safety
Which material is most commonly used for the conductor of a house wiring cable because of its high conductivity and reasonable cost?
- Iron
- Copper Correct answer.
- Nichrome
- Tungsten
Explanation
Copper has very low resistivity, good ductility and resists corrosion, so it is the standard conductor for domestic and industrial wiring. Iron has much higher resistivity and corrodes easily, while tungsten and nichrome are chosen for heating and filament duty, not for carrying supply current over long runs.
Question 3Basic Electrical Fundamentals and Safety
What is the SI unit of electrical resistance?
- Ampere
- Watt
- Ohm Correct answer.
- Volt
Explanation
Resistance is measured in ohms, defined as the resistance that allows one ampere to flow when one volt is applied across it. The volt measures potential difference, the ampere measures current and the watt measures power, so each of the other units describes a different quantity in the circuit.
Question 4Basic Electrical Fundamentals and Safety
A resistor of 12 ohm carries a current of 2.5 A. What is the voltage drop across it?
- 4.8 V
- 14.5 V
- 30 V Correct answer.
- 9.5 V
Explanation
Ohm's law states V = I x R, so 2.5 A multiplied by 12 ohm gives 30 V. The other values come from dividing instead of multiplying or from adding and subtracting the given numbers, which have no physical meaning here.
Question 5Basic Electrical Fundamentals and Safety
Which of the following is the correct first action when a person is found in contact with a live conductor?
- Throw water on the conductor to cool it
- Switch off the supply before touching the person Correct answer.
- Wait for the person to release the conductor
- Pull the person away by the arm immediately
Explanation
The supply must be isolated first, because touching a victim still in contact with a live conductor makes the rescuer a second victim. Only after isolation, or after the conductor is moved with a dry insulating object, should first aid and artificial respiration begin.
Question 6Basic Electrical Fundamentals and Safety
Why is a fuse connected in the phase (live) wire rather than in the neutral wire?
- Because fuses cannot carry return current
- To reduce the voltage drop in the neutral conductor
- Because the neutral wire carries no current at any time
- So that the appliance is isolated from the live supply when the fuse blows Correct answer.
Explanation
A fuse in the phase wire clears the fault by disconnecting the appliance from the live supply, so the equipment and anyone touching it are left at earth potential. If the fuse were in the neutral, the appliance would remain connected to the live line even after the fuse blew.
Question 7Basic Electrical Fundamentals and Safety
Which instrument is used to measure the current flowing in a circuit without breaking the conductor?
- Wattmeter
- Megger
- Frequency meter
- Clamp meter Correct answer.
Explanation
A clamp meter has a split core that is clipped around a single conductor and senses the magnetic field produced by the current, so the circuit need not be opened. A megger measures insulation resistance, a wattmeter measures power and a frequency meter measures supply frequency.
Question 8Basic Electrical Fundamentals and Safety
A coil of wire is connected across a 230 V supply and draws 5 A. What is its resistance?
- 235 ohm
- 1150 ohm
- 0.0217 ohm
- 46 ohm Correct answer.
Explanation
From Ohm's law, R = V / I, so 230 V divided by 5 A gives 46 ohm. Multiplying the two values gives power in watts rather than resistance, and the reciprocal of that product has no meaning in this context.
Question 9Basic Electrical Fundamentals and Safety
Three resistors of 4 ohm, 6 ohm and 10 ohm are connected in series. What is the total resistance of the combination?
- 10 ohm
- 2.4 ohm
- 1.9 ohm
- 20 ohm Correct answer.
Explanation
In a series circuit the same current passes through every element, so the resistances simply add: 4 + 6 + 10 = 20 ohm. The smaller values would arise from parallel formulas, which do not apply to this connection.
Question 10Basic Electrical Fundamentals and Safety
Two resistors of 6 ohm and 3 ohm are connected in parallel across a 12 V supply. What current does the supply deliver?
- 4 A
- 6 A Correct answer.
- 0.75 A
- 1.33 A
Explanation
The parallel equivalent is (6 x 3)/(6 + 3) = 2 ohm, so the supply current is 12 V / 2 ohm = 6 A. This equals the sum of the branch currents, 2 A through the 6 ohm and 4 A through the 3 ohm resistor.
Question 11Basic Electrical Fundamentals and Safety
An electric iron rated 1000 W is used for 3 hours. How many units (kWh) of energy does it consume?
- 1 kWh
- 0.33 kWh
- 3 kWh Correct answer.
- 10 kWh
Explanation
Energy in kWh equals power in kilowatts multiplied by time in hours, so 1 kW x 3 h = 3 kWh. One commercial unit of electricity is exactly one kilowatt-hour, which makes the billing calculation direct.
Question 12Basic Electrical Fundamentals and Safety
What is the primary purpose of earthing an electrical installation?
- To reduce the monthly electricity bill
- To increase the voltage available at the socket
- To improve the power factor of the load
- To provide a low-resistance path so fault current trips the protective device Correct answer.
Explanation
Earthing bonds exposed metalwork to the general mass of earth so that a fault to the frame produces a large current, which quickly operates the fuse or breaker. It also holds the metalwork near earth potential, limiting the shock voltage a person can touch.
Question 13Basic Electrical Fundamentals and Safety
A 60 W lamp and a 100 W lamp, both rated 230 V, are connected in series across 230 V. Which lamp glows brighter?
- The 100 W lamp
- Both glow equally
- Neither glows
- The 60 W lamp Correct answer.
Explanation
In series both lamps carry the same current, so the lamp with the higher resistance dissipates more power. The 60 W lamp has the higher resistance because its rated power at the same voltage is lower, so it develops the greater voltage drop and glows brighter.
Question 14Basic Electrical Fundamentals and Safety
Why is a megger test voltage applied between the conductor and earth before energising a new installation?
- To measure the earth electrode current during a fault
- To confirm that the fuse rating matches the cable
- To verify that the insulation resistance is high enough to be safe Correct answer.
- To check the polarity of the socket outlets
Explanation
A megger applies a high DC voltage and measures the tiny leakage current through the insulation, giving a resistance value in megohms. A low reading indicates moisture, damage or contamination that would permit dangerous leakage when the supply is switched on.
Question 15Basic Electrical Fundamentals and Safety
Which of the following is the correct sequence of the wiring system in a domestic installation from the supply to the load?
- Distribution board, service cable, load, main switch
- Load, sub-circuit, main switch, service cable
- Main switch, load, service cable, distribution board
- Service cable, main switch, distribution board, sub-circuit, load Correct answer.
Explanation
The supply enters through the service cable to the main switch and meter, then feeds the distribution board, which splits the supply into final sub-circuits that supply the individual loads. Energy therefore flows in that fixed order from the source to the point of use.
Question 16Basic Electrical Fundamentals and Safety
A fuse of 5 A protects a circuit. Which statement correctly describes its operation?
- It melts when the current exceeds its rating for a sufficient time Correct answer.
- It opens the circuit when the earth leakage exceeds 30 mA
- It opens only when the voltage exceeds 230 V
- It limits the current to exactly 5 A at all times
Explanation
A fuse element is a calibrated piece of metal that heats and melts when the current exceeds its rating, so it is an overcurrent device with an inverse time characteristic. It responds to current, not to voltage, and it does not sense earth leakage.
Question 17Basic Electrical Fundamentals and Safety
What is the resistance of a copper conductor if its length is doubled and its cross-sectional area is halved, the original resistance being R?
- 2R
- R/4
- 4R Correct answer.
- R/2
Explanation
Resistance is proportional to length and inversely proportional to area, so doubling the length doubles the resistance while halving the area doubles it again. The combined effect is 2 x 2 = 4 times the original value.
Question 18Basic Electrical Fundamentals and Safety
In a two-way switch circuit used at the top and bottom of a staircase, what happens when either switch is toggled?
- The lamp stays in its previous state
- The lamp always turns off
- The lamp changes state, whether it was on or off Correct answer.
- The lamp always turns on
Explanation
Two-way switches are wired so that the two common terminals feed the lamp and the travellers are cross-connected, making the circuit complete in either switch position. Toggling either switch therefore reverses the state of the lamp, which is the reason the arrangement is used on stairs.
Question 19Basic Electrical Fundamentals and Safety
A 230 V, 2 kW heater is connected to a 230 V supply. What current does it draw?
- 8.7 A Correct answer.
- 2 A
- 0.115 A
- 460 A
Explanation
Current equals power divided by voltage, so 2000 W / 230 V gives about 8.7 A. The heater element resistance is then about 26 ohm, and the circuit must be protected with a fuse or breaker rated above this current.
Question 20Basic Electrical Fundamentals and Safety
Why is a capacitor used in a fluorescent tube luminaire?
- To improve the power factor of the inductive choke circuit Correct answer.
- To provide the starting voltage surge
- To increase the tube current and brightness
- To protect the tube from overvoltage
Explanation
The choke is an inductor, so the luminaire draws a lagging current and has a poor power factor. A capacitor connected across the supply draws a leading current that partly cancels this, raising the power factor and reducing the supply current.
Question 21Basic Electrical Fundamentals and Safety
A 100 W lamp and a 100 W heater are both operated at their rated voltage for the same time. Which statement is correct?
- The heater consumes more energy because it gives heat
- Neither consumes energy because both are resistive
- The lamp consumes more energy because it gives light
- Both consume the same electrical energy but the heater delivers more heat Correct answer.
Explanation
Electrical energy consumed depends only on power and time, so two 100 W appliances running for the same period use identical energy. The difference lies in the form of the output: the heater converts almost all of it into heat, while the lamp converts a large part into light.
Question 22Basic Electrical Fundamentals and Safety
In a circuit, the voltage across a resistor is 20 V and the current through it is 0.5 A. What power is dissipated, and what is the resistance?
- 40 W and 10 ohm
- 40 W and 40 ohm
- 10 W and 40 ohm Correct answer.
- 10 W and 10 ohm
Explanation
Power is the product of voltage and current, 20 V x 0.5 A = 10 W, and resistance is voltage divided by current, 20 V / 0.5 A = 40 ohm. Checking with I squared R gives 0.25 x 40 = 10 W, which confirms both answers.
Question 23Basic Electrical Fundamentals and Safety
An RCCB of 30 mA sensitivity is installed in a circuit. What does this rating indicate?
- It limits the supply voltage to 30 mV
- It trips when the load current exceeds 30 mA
- It trips when the insulation resistance falls below 30 megohm
- It trips when the residual current to earth reaches about 30 mA Correct answer.
Explanation
An RCCB compares the current in the phase and neutral conductors and trips when the difference, which is the current leaking to earth, exceeds its sensitivity. The 30 mA value is chosen because it is near the threshold for dangerous ventricular fibrillation in a healthy adult.
Question 24Basic Electrical Fundamentals and Safety
Why does a short circuit produce a very large current and a risk of fire?
- The earth wire injects extra current into the circuit
- The resistance between the conductors becomes almost zero, so current is limited only by the source and cable impedance Correct answer.
- The power factor becomes unity during the fault
- The supply voltage rises sharply during the fault
Explanation
A short circuit provides a near-zero resistance path between phase and neutral or phase and earth, so by Ohm's law the current rises to a value limited mainly by the source impedance and the cable resistance. The resulting I squared R heating can melt insulation and ignite surrounding material unless the protective device clears the fault quickly.
Question 25Electrical Wiring, Cables and Accessories
किसी घरेलू तार में उपयोग होने वाले ताँबे के चालक का सबसे उपयुक्त गुण क्या है जिसके कारण इसे तारों के लिए चुना जाता है?
- उच्च प्रतिरोध और निम्न तन्य शक्ति
- उच्च प्रतिरोध और अच्छी ऊष्मा चालकता
- निम्न प्रतिरोध और अच्छी विद्युत चालकता Correct answer.
- निम्न चालकता और उच्च कठोरता
Explanation
ताँबे का विशिष्ट प्रतिरोध बहुत कम होता है और उसकी चालकता अधिक होती है, इसलिए उसी अनुप्रस्थ काट पर धारा प्रवाह में ऊर्जा हानि कम होती है। घरेलू तारों में इसी कारण ऐनिल्ड ताँबे के बहु-तंतु चालक प्रयोग होते हैं।
Question 26Electrical Wiring, Cables and Accessories
PVC अवरोधन वाले तारों के लिए अधिकतम अनुमत चालक तापमान सामान्यतः कितना माना जाता है?
- 250 डिग्री सेल्सियस
- 40 डिग्री सेल्सियस
- 150 डिग्री सेल्सियस
- 70 डिग्री सेल्सियस Correct answer.
Explanation
सामान्य PVC (पॉलीविनाइल क्लोराइड) अवरोधन की सतत कार्य तापमान सीमा लगभग 70 डिग्री सेल्सियस होती है। इससे अधिक ताप पर अवरोधन नरम होकर गुण खोने लगता है और उम्र घटती है।
Question 27Electrical Wiring, Cables and Accessories
किसी भवन की वायरिंग में तारों के लिए उपयोग होने वाले सबसे सामान्य वाहक (conduit) का कार्य क्या है?
- तारों का तापमान बढ़ाकर अवरोधन सुखाना
- परिपथ का प्रतिरोध बढ़ाकर धारा घटाना
- तारों को यांत्रिक क्षति से बचाना और मार्ग देना Correct answer.
- विद्युत ऊर्जा को यांत्रिक ऊर्जा में बदलना
Explanation
वाहक (conduit) तारों के लिए सुरक्षित मार्ग बनाता है और उन्हें यांत्रिक आघात, नमी व चूहों आदि से बचाता है। यह विद्युत परिपथ का कार्यात्मक अंग नहीं बल्कि सुरक्षात्मक आवरण है।
Question 28Electrical Wiring, Cables and Accessories
स्विच को सदैव किस तार में लगाया जाना चाहिए?
- किसी भी तार में, कोई अंतर नहीं
- फेज (लाइव) तार में Correct answer.
- अर्थ तार में
- न्यूट्रल तार में
Explanation
स्विच फेज तार में लगाने से स्विच बंद करते ही उपकरण फेज से अलग हो जाता है और उसमें वोल्टता नहीं रहती। यदि स्विच न्यूट्रल में हो तो उपकरण बंद होने पर भी उसका आंतरिक भाग फेज से जुड़ा रहता है, जिससे करंट लगने का खतरा बना रहता है।
Question 29Electrical Wiring, Cables and Accessories
किसी तार का अनुप्रस्थ काट क्षेत्रफल 1.5 वर्ग मिलीमीटर है। यह मान किस बात को दर्शाता है?
- तार की कुल लंबाई
- तार पर लगे फ्यूज का अनुमत धारा
- चालक के धातु भाग का क्षेत्रफल Correct answer.
- तार के अवरोधन की मोटाई
Explanation
तार का 'साइज' उसके चालक (धातु) भाग के अनुप्रस्थ काट का क्षेत्रफल बताता है, जो धारा वहन क्षमता निर्धारित करता है। अवरोधन की मोटाई और लंबाई इससे स्वतंत्र राशियाँ हैं।
Question 30Electrical Wiring, Cables and Accessories
विद्युत परिपथ में अर्थ (earthing) का मुख्य उद्देश्य क्या है?
- तारों का रंग बदलना
- धातु आवरण को भू-विभव पर रखकर करंट लगने से बचाना Correct answer.
- धारा बढ़ाकर उपकरण तेज चलाना
- परिपथ का शक्ति गुणांक सुधारना
Explanation
अर्थ तार धातु आवरण या उपकरण के धातु भाग को भू-विभव के निकट रखता है। अवरोधन फेल होने पर दोष धारा भूमि में चली जाती है और संरक्षण युक्ति जल्दी कार्य करती है, जिससे व्यक्ति को झटका नहीं लगता।
Question 31Electrical Wiring, Cables and Accessories
निम्नलिखित में से कौन-सा तार बिना अर्थ तार वाले परिपथ में उपकरण के धातु आवरण से जोड़ा जाना चाहिए?
- फेज तार
- केवल फ्यूज तार
- अर्थ तार Correct answer.
- न्यूट्रल तार
Explanation
उपकरण के धातु आवरण को अर्थ तार से जोड़ना अनिवार्य है ताकि अवरोधन फेल होने पर आवरण पर खतरनाक वोल्टता न रहे। फेज या न्यूट्रल से जोड़ने पर आवरण स्वयं सक्रिय हो जाएगा।
Question 32Electrical Wiring, Cables and Accessories
किसी तार का अवरोधन प्रतिरोध मेगर से मापा जा रहा है। परीक्षण से पहले तार को क्या करना चाहिए?
- मुख्य आपूर्ति से जोड़े रखना
- परिपथ से पूर्णतः अलग करके डिस्चार्ज करना Correct answer.
- केवल फ्यूज निकाल देना
- तार को पानी में डुबो देना
Explanation
मेगर उच्च परीक्षण वोल्टता लगाता है, अतः तार को स्रोत से पूरी तरह अलग करके संचित आवेश डिस्चार्ज करना चाहिए। इससे उपकरण, मापक और व्यक्ति सभी सुरक्षित रहते हैं।
Question 33Electrical Wiring, Cables and Accessories
किसी घरेलू परिपथ में 10 ऐम्पियर की धारा के लिए न्यूनतम किस आकार का ताँबे का तार उपयुक्त माना जाता है?
- 6.0 वर्ग मिलीमीटर
- 0.5 वर्ग मिलीमीटर
- 1.0 वर्ग मिलीमीटर
- 1.5 वर्ग मिलीमीटर Correct answer.
Explanation
सामान्य तापमान पर 1.5 वर्ग मिलीमीटर ताँबे का तार लगभग 10 से 14 ऐम्पियर तक सुरक्षित रूप से वहन कर सकता है, इसलिए प्रकाश परिपथ के लिए यह न्यूनतम मानक साइज है। बहुत पतला तार गर्म होकर अवरोधन जला सकता है।
Question 34Electrical Wiring, Cables and Accessories
किसी उपकरण के धातु आवरण में दोष धारा बहने पर तुरंत परिपथ बंद करने वाली युक्ति कौन-सी है?
- संधारित्र
- MCB Correct answer.
- प्रतिरोध
- साधारण स्विच
Explanation
मिनिएचर सर्किट ब्रेकर (MCB) अधिक धारा या दोष धारा पर स्वतः ट्रिप करके परिपथ को स्रोत से अलग कर देता है। यह पुनः सेट किया जा सकता है और फ्यूज की तुलना में तेज तथा सुरक्षित संरक्षण देता है।
Question 35Electrical Wiring, Cables and Accessories
घरेलू वायरिंग में फेज, न्यूट्रल और अर्थ तारों के लिए मानक रंग क्रमशः क्या हैं?
- लाल, काला या नीला, हरा-पीला Correct answer.
- नीला, हरा, लाल
- हरा, लाल, काला
- पीला, हरा, नीला
Explanation
भारतीय/अंतर्राष्ट्रीय अभ्यास में फेज के लिए लाल या भूरा, न्यूट्रल के लिए काला या नीला, तथा अर्थ के लिए हरा-पीला रंग प्रयोग होता है। अर्थ के लिए हरा-पीला संयोजन विशेष रूप से पहचान योग्य है।
Question 36Electrical Wiring, Cables and Accessories
किसी मोटर के धातु आवरण और अर्थ इलेक्ट्रोड के बीच 500 वोल्ट मेगर से मापा गया प्रतिरोध 0.8 मेगा ओम है। इसका सर्वोत्तम निष्कर्ष क्या है?
- अर्थ संयोजन में दोष है और सुधार आवश्यक है Correct answer.
- अर्थ संयोजन संतोषजनक है
- मोटर अधिक गति से चलेगी
- मेगर की बैटरी समाप्त है
Explanation
सुरक्षित अर्थ संयोजन के लिए प्रतिरोध सामान्यतः 1 मेगा ओम से अधिक होना चाहिए; 0.8 मेगा ओम संदिग्ध रूप से कम है और दोषपूर्ण अर्थ या नमी की ओर संकेत करता है। अतः संयोजन जाँचकर सुधारना चाहिए।
Question 37Electrical Wiring, Cables and Accessories
किसी केबल में ताँबे के बहुत पतले अनेक तंतु क्यों प्रयोग किए जाते हैं?
- तार की लंबाई बढ़ाने के लिए
- तार को लचीला बनाने और मुड़ने पर टूटने से बचाने के लिए Correct answer.
- तार का रंग बदलने के लिए
- तार को कठोर और भंगुर बनाने के लिए
Explanation
अनेक पतले तंतुओं वाला (स्ट्रैंडेड) चालक लचीला होता है और बार-बार मुड़ने अथवा कठिन मार्ग से गुजारने पर टूटता नहीं। यही कारण है कि घरेलू उपकरणों के कॉर्ड और वाहक में तंतुयुक्त तार प्रयोग होते हैं।
Question 38Electrical Wiring, Cables and Accessories
किसी भवन में तारों को दीवार के अंदर ले जाने के लिए सबसे उपयुक्त विधि कौन-सी है?
- तारों को दीवार के बाहर खुला लटकाना
- तारों को सीधे प्लास्टर में डालकर चूना लगाना
- वाहक (conduit) में डालकर दीवार में गाड़ना Correct answer.
- तारों को लकड़ी के पट्टे पर कील से बाँधना
Explanation
वाहक दीवार के अंदर तारों के लिए सुरक्षित मार्ग बनाता है और उन्हें नमी तथा यांत्रिक क्षति से बचाता है। इससे भविष्य में तार बदलना या जोड़ना भी सरल हो जाता है।
Question 39Electrical Wiring, Cables and Accessories
किसी परिपथ में 1.5 वर्ग मिलीमीटर ताँबे के तार पर 20 ऐम्पियर का भार लगातार लगाया जा रहा है। सर्वोत्तम कार्रवाई क्या है?
- तार के चारों ओर टेप लपेटकर मोटा करना
- तार को वैसे ही रखना क्योंकि वह चल रहा है
- फ्यूज हटाकर सीधा जोड़ देना
- अधिक क्षमता वाले तार या अलग परिपथ का प्रयोग करना Correct answer.
Explanation
1.5 वर्ग मिलीमीटर ताँबे के तार की सुरक्षित धारा क्षमता लगभग 10 से 14 ऐम्पियर है, इसलिए 20 ऐम्पियर का सतत भार उसे अत्यधिक गर्म करेगा। उपयुक्त उपाय तार का साइज बढ़ाना या भार को अलग परिपथ पर बाँटना है।
Question 40Electrical Wiring, Cables and Accessories
किसी उपकरण के पास लगे स्विच बोर्ड में तारों के जोड़ कैसे बनाए जाने चाहिए?
- जोड़ को दीवार में दबा देना
- मरोड़कर खुला छोड़ देना
- उपयुक्त कनेक्टर या टर्मिनल में कसकर जोड़ना Correct answer.
- केवल टेप से चिपकाना
Explanation
जोड़ उपयुक्त टर्मिनल, कनेक्टर या जंक्शन बॉक्स में कसकर बनाया जाता है ताकि संपर्क प्रतिरोध कम रहे और ऊष्मा उत्पन्न न हो। ढीला या खुला जोड़ चिंगारी और आग का कारण बन सकता है।
Question 41Electrical Wiring, Cables and Accessories
किसी घरेलू परिपथ में तारों को वाहक में खींचते समय तारों की कुल भराई (fill) सामान्यतः कितनी रखी जाती है?
- भराई की कोई सीमा नहीं होती
- वाहक के आंतरिक क्षेत्रफल का 100 प्रतिशत
- वाहक के आंतरिक क्षेत्रफल का लगभग 90 प्रतिशत
- वाहक के आंतरिक क्षेत्रफल का लगभग 40 प्रतिशत Correct answer.
Explanation
वाहक में तारों की भराई लगभग 40 प्रतिशत तक सीमित रखी जाती है ताकि तार खींचने में कठिनाई न हो और ऊष्मा का निकास अच्छा रहे। अधिक भराई से तार जाम हो सकते हैं और अवरोधन क्षतिग्रस्त हो सकता है।
Question 42Electrical Wiring, Cables and Accessories
किसी केबल के अवरोधन प्रतिरोध का मान समय के साथ घटता जा रहा है और केबल गर्म रहती है। सबसे संभावित कारण क्या है?
- अवरोधन में नमी या अधिभार के कारण क्षय Correct answer.
- केबल का साइज आवश्यकता से अधिक होना
- केबल का ठीक से रंगीन होना
- अर्थ तार का हरा-पीला होना
Explanation
नमी के प्रवेश या लगातार अधिभार से अवरोधन की गुणवत्ता घटती है, जिससे प्रतिरोध कम होता है और केबल अधिक गर्म रहती है। यह दोष आगे अवरोधन भंग और लघु परिपथ का कारण बन सकता है।
Question 43Electrical Wiring, Cables and Accessories
किसी परिपथ में 230 वोल्ट पर 2 किलोवाट का भार है। इसके लिए लगभग कितनी धारा प्रवाहित होगी?
- लगभग 0.87 ऐम्पियर
- लगभग 17.4 ऐम्पियर
- लगभग 4.3 ऐम्पियर
- लगभग 8.7 ऐम्पियर Correct answer.
Explanation
एकल फेज परिपथ में धारा = शक्ति / वोल्टता = 2000 / 230, जो लगभग 8.7 ऐम्पियर होती है। इसी धारा के आधार पर तार का साइज और संरक्षण युक्ति चुनी जाती है।
Question 44Electrical Wiring, Cables and Accessories
किसी घरेलू वायरिंग में बिजली के झटके से बचाव के लिए सबसे अधिक संवेदनशील युक्ति कौन-सी है?
- फ्यूज
- RCCB Correct answer.
- MCB
- स्विच
Explanation
अवशिष्ट धारा परिपथ ब्रेकर (RCCB) फेज और न्यूट्रल धाराओं के अंतर को महसूस करता है और मिलीऐम्पियर स्तर पर ही परिपथ तोड़ देता है। यही युक्ति भूमि में रिसाव धारा से व्यक्ति को झटके से बचाने में सबसे प्रभावी है।
Question 45Electrical Wiring, Cables and Accessories
किसी तार के अवरोधन पर उसका अनुमत धारा, वोल्टता और निर्माता का नाम अंकित होता है। इस अंकन का मुख्य उद्देश्य क्या है?
- तार की लंबाई बढ़ाना
- तार का रंग बदलना
- तार को सजावटी बनाना
- सही चयन और सुरक्षित उपयोग सुनिश्चित करना Correct answer.
Explanation
अवरोधन पर अंकित धारा और वोल्टता रेटिंग से पता चलता है कि तार किस परिपथ में सुरक्षित रहेगा। इससे गलत साइज चुनने और अधिभार से होने वाली दुर्घटनाओं को रोका जा सकता है।
Question 46Electrical Wiring, Cables and Accessories
किसी परिपथ में 1.5 वर्ग मिलीमीटर ताँबे का तार है और 6 ऐम्पियर का MCB लगा है। उपकरण खराब होकर 25 ऐम्पियर की दोष धारा बहने लगती है। सर्वाधिक संभावित परिणाम क्या होगा?
- MCB की रेटिंग बढ़ जाएगी
- तार पहले जल जाएगा और MCB कभी नहीं ट्रिप करेगा
- दोष धारा शून्य हो जाएगी
- तार सुरक्षित रहेगा और MCB ट्रिप कर देगा Correct answer.
Explanation
25 ऐम्पियर दोष धारा MCB की 6 ऐम्पियर रेटिंग से कई गुना अधिक है, इसलिए MCB तुरंत ट्रिप करेगा और तार को अधिभार से बचाएगा। सही समन्वय का यही उद्देश्य है कि संरक्षण युक्ति तार की क्षमता से पहले कार्य करे।
Question 47Electrical Wiring, Cables and Accessories
किसी भवन की वायरिंग में ताँबे के तार के स्थान पर उसी अनुप्रस्थ काट का ऐलुमिनियम तार लगाया गया है। इसका मुख्य परिणाम क्या होगा?
- तार का प्रतिरोध घट जाएगा
- तार की धारा वहन क्षमता बढ़ जाएगी
- तार की लंबाई घट जाएगी
- तार अधिक गर्म होकर अवरोधन क्षतिग्रस्त हो सकता है Correct answer.
Explanation
ऐलुमिनियम का विशिष्ट प्रतिरोध ताँबे से लगभग 1.6 गुना अधिक है, इसलिए समान काट पर प्रतिरोध और ऊष्मा अधिक होगी। परिणामस्वरूप उसी भार पर तार अधिक गर्म होकर अवरोधन क्षतिग्रस्त कर सकता है।
Question 48Electrical Wiring, Cables and Accessories
किसी उपकरण के अवरोधन प्रतिरोध की माप 0.3 मेगा ओम आई है जबकि उसका केबल नम स्थान से गुजरता है। सर्वोत्तम तकनीकी निर्णय क्या है?
- केबल सुखाकर या बदलकर पुनः परीक्षण करना Correct answer.
- माप को स्वीकार करके उपकरण चालू करना
- मेगर की रेंज बदलकर माप दोहराना
- न्यूट्रल और अर्थ तार को आपस में जोड़ना
Explanation
नमी के कारण अवरोधन प्रतिरोध सामान्य मान से बहुत कम हो जाता है और 0.3 मेगा ओम पर उपकरण चलाना खतरनाक है। पहले कारण दूर करना चाहिए, अर्थात केबल सुखाना या बदलना, फिर परीक्षण दोहराना चाहिए।
Question 49Electrical Wiring, Cables and Accessories
किसी वाहक (conduit) में तार खींचते समय वाहक के भीतर तीव्र 90 डिग्री कोण बनाया गया है। इसका मुख्य दोष क्या है?
- वाहक में नमी का न आना
- वाहक की धारा क्षमता बढ़ना
- तार खींचने में कठिनाई और अवरोधन क्षति Correct answer.
- तार की लंबाई का स्वतः घटना
Explanation
तीव्र कोण पर तार खींचते समय घर्षण बढ़ता है और अवरोधन के फटने या चालक टूटने की संभावना रहती है। मानक अभ्यास में कोमल मोड़ या उपयुक्त कोहनी (bend) का प्रयोग किया जाता है।
Question 50Electrical Wiring, Cables and Accessories
किसी घरेलू वायरिंग में स्विच बोर्ड के अंदर ताँबे के तारों को आपस में जोड़ने के लिए सबसे उपयुक्त विधि कौन-सी है?
- तारों को पीतल की चूड़ी (terminal) पर पेच से कसकर जोड़ना Correct answer.
- तारों के सिरों को केवल टिन करके पास-पास रख देना
- तारों को केवल मोड़कर टेप से लपेट देना
- तारों को सीधा एक-दूसरे पर रखकर स्टेपल से दबा देना
Explanation
विद्युत जोड़ का उद्देश्य कम प्रतिरोध वाला यांत्रिक रूप से मजबूत संपर्क बनाना है, इसलिए तार को टर्मिनल पर पेच या उपयुक्त क्लैंप से कसा जाता है। केवल मोड़ना या टेप लपेटना समय के साथ ढीला पड़कर गर्म होने और स्पार्किंग का कारण बनता है।