UPMSP High School Solar Repair flashcards
UPMSP High School Solar Repair · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Standard Test Conditions
- Irradiance 1000 W/m², cell temperature 25 °C, and AM 1.5 spectrum. Nameplate power, voltage, and current ratings are measured here, so real-world output differs with temperature and irradiance.
- Maximum power point
- The point on a module's I-V curve where voltage times current is greatest. MPPT controllers track this point continuously as irradiance and temperature change through the day.
- Bypass diode function
- A diode across a module substring that conducts when that substring is shaded, allowing current to bypass it. This limits hot-spot heating and preserves the rest of the string's output.
- Fill factor
- The ratio of maximum power to the product of open-circuit voltage and short-circuit current. A squarer I-V curve gives a higher fill factor, typically 0.75–0.82 for crystalline silicon.
- Temperature coefficient of power
- The percentage change in maximum power per degree Celsius of cell temperature. For crystalline silicon it is roughly −0.35 to −0.45 %/°C, so hot modules produce less power.
- Absorption charge stage
- A constant-voltage stage at the elevated absorption setpoint, during which charge current tapers as the battery fills. It restores most capacity before the controller drops to float voltage.
- Depth of discharge
- The fraction of a battery's capacity removed during discharge. Deeper discharges shorten lead-acid cycle life sharply, so systems are usually sized to limit DoD to about 50 %.
- MPPT controller
- A DC-DC converter that continuously adjusts the array operating voltage to its maximum power point, then converts the surplus voltage into extra charge current for the battery.
- Anti-islanding protection
- A grid-tied inverter function that detects loss of grid supply and shuts down within the required time, preventing the inverter from energising a dead grid during utility work.
- Pure sine wave inverter
- An inverter producing a smooth sinusoidal AC output. It runs motors, chargers, and sensitive electronics correctly, unlike modified sine wave units that can cause overheating and buzzing.
- Voltage drop formula
- V_drop = 2 × L × I × ρ / A for a two-wire run, where L is one-way length, ρ is resistivity (copper ≈ 0.0175 Ω·mm²/m), and A is cross-sectional area.
- String fuse rating
- The fuse protecting a PV string is typically 1.25 × short-circuit current, and must not exceed the module's maximum series fuse rating. It protects cables, not the modules.
- Equipotential bonding
- Connecting module frames, rails, and equipment chassis to a common earth electrode so all metalwork sits at the same potential, preventing shock and enabling fault-current paths.
- Shading survey
- A site assessment using a sun-path tool or app to map obstructions across the year. It determines whether trees, chimneys, or cables will shade the array in critical months.
- Module tilt rule of thumb
- For year-round yield in the tropics, tilt roughly latitude minus 10°. Steeper tilts favour winter production; flatter tilts favour summer and reduce dust accumulation.
- Insulation resistance test
- A megger test applying 500 V or 1000 V DC between array conductors and earth. A healthy array reads above 1 MΩ; low readings indicate water ingress or cable damage.
- I-V curve tracing
- A field test plotting current against voltage across the array's operating range. Steps or knees reveal shaded or failed substrings; comparing to the datasheet at measured conditions quantifies degradation.
- Open-circuit voltage test
- Measuring string voltage with no load and comparing to the temperature-corrected sum of module V_oc values. A low reading indicates a broken series link or failed bypass diode.
- Thermal imaging inspection
- Using an infrared camera to find hot spots, failed bypass diodes, loose terminations, and cell cracks. Temperature anomalies reveal faults that a voltmeter alone cannot detect.
- Performance ratio
- Actual energy output divided by the energy the array would produce at its rated power under the measured irradiance. A sudden drop above 10 % signals a fault.
- Soiling loss
- The reduction in output caused by dust, pollen, bird droppings, or salt on the glass. Cleaning restores yield; frequent cleaning is needed at dusty or coastal sites.
- Snail trails
- Discoloured lines along cell fingers caused by encapsulant degradation and silver paste reaction. They are a warranty-relevant degradation sign and can reduce yield.
- CAT III meter rating
- A safety rating for test instruments used on distribution-level circuits. A 1000 V DC array requires a meter rated at least 1000 V DC on the applicable range.
- Lockout tagout
- Isolating AC and DC supplies, locking the isolator, tagging it, and verifying absence of voltage before work. The tester is proved on a known live source before and after.
- Hydrogen hazard
- Flooded lead-acid batteries release hydrogen while charging. Ventilate the battery room and avoid sparks, flames, or smoking near the bank to prevent explosion.
- Solar home system sizing
- Daily appliance watt-hours divided by system voltage and depth of discharge gives battery amp-hours. Array watts equal daily watt-hours divided by peak sun hours and derating.
- Dry-run protection
- A pump controller feature that stops the pump when the water source runs dry, preventing motor overheating and damage. Essential for solar water pumping systems.
- Solar lantern battery
- Most solar lanterns use LiFePO₄ or lithium-ion cells with an integrated controller. Usable watt-hours, not nominal capacity, determine the actual runtime promised to users.
- Inverter surge rating
- The short-term power an inverter can deliver, often twice its continuous rating for a few seconds. It must exceed the starting surge of motor loads such as fridges and pumps.
- Blocking diode
- A series diode that prevents reverse current from flowing into a weaker parallel string or from the battery back into the array at night, protecting modules from damage.
- Float charge
- A lower constant voltage applied after absorption to maintain a fully charged battery while compensating for self-discharge, without causing gassing or overcharge.
- Earth continuity test
- A low-resistance measurement between metalwork and the earth electrode, confirming the bonding path is intact. High resistance means a shock hazard under fault conditions.