WBBSE Madhyamik Vocational Plumbing flashcards
WBBSE Madhyamik Vocational Plumbing · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Nominal bore (NB)
- The approximate internal diameter used to designate a pipe size; for a given NB a heavier schedule means a thicker wall and a smaller actual bore.
- Water seal depth
- The vertical depth of water held in a trap that stops sewer gas entering a building; commonly 50 mm for soil fittings and 25 to 38 mm for waste fittings.
- Self-cleansing velocity
- The minimum flow velocity in a drain, about 0.6 metres per second, that keeps solids moving and prevents silt deposition; it is achieved by laying the drain to the correct gradient.
- Soil pipe versus waste pipe
- A soil pipe carries human waste from a WC, usually 100 mm nominal; a waste pipe carries sullage from sinks and basins, usually 32 to 75 mm.
- Anti-siphon vent pipe
- A pipe that admits air into the drainage system to equalise pressure and protect trap seals from being sucked out; it terminates above roof level, clear of windows.
- Separate sewerage system
- A drainage arrangement in which foul sewage and storm water are carried in two separate sewers, so that rainwater does not overload the treatment works.
- Solvent cement joint
- A joint for PVC-U or CPVC pipe made by cleaning both surfaces, applying solvent cement, pushing the spigot fully into the socket with a quarter turn, and allowing full cure.
- PTFE tape use
- A thin tape wrapped around male pipe threads, in the direction of the thread, to seal threaded joints in water lines; it is not a substitute for a correctly cut thread.
- Pipe cutter reaming
- The operation of removing the internal burr left by a pipe cutter with a reamer or half-round file, so that flow is not restricted and the joint seats squarely.
- Galvanised iron pipe
- Mild steel pipe coated with zinc by hot dipping to resist corrosion; it is joined by threaded sockets and used for exposed water supply and risers.
- Direct water supply
- A system in which each fixture is fed straight from the mains without storage; it depends on continuous mains pressure and gives no reserve during cuts.
- Indirect water supply
- A system in which water is stored in a tank and then distributed by gravity or a pump; it provides a reserve and a steady head at the fixtures.
- Ball valve or float valve
- A valve inside a flushing cistern or tank that opens as the water level falls and closes when the cistern is full, controlling the refill.
- Water hammer
- Banging and vibration in a pipe caused by sudden valve closure; it is controlled by an air vessel, an arrester, or slow-closing valves.
- Gate valve versus globe valve
- A gate valve isolates flow with little resistance when fully open; a globe valve regulates flow but adds resistance because the flow turns through the body.
- Check valve
- A non-return valve that allows flow in one direction only, used to prevent backflow and to protect the supply from contamination.
- Pipe wrench size
- The size marked on a Stillson wrench, such as 8, 10, 12, 14, 18, 24, 36 or 48 inches, indicates the pipe diameter range the jaws can grip.
- Pipe vice
- A bench-mounted vice with shaped jaws that holds pipe horizontally for cutting, filing, and threading without crushing or marking the pipe.
- Hacksaw blade selection
- Blade teeth per inch are chosen by wall thickness: 18 or 24 teeth per inch for general metal pipe, finer 32 teeth per inch for thin-wall copper and plastic.
- Fire extinguisher classes
- Extinguishers are chosen by fire class: water for wood and paper, foam or CO2 for oil and paint, CO2 or dry powder for gas and live electrical equipment.
- Scale on a drawing
- A ratio such as 1:50 or 1:100 that relates a drawn length to the real length; a measurement on a 1:50 drawing is multiplied by 50.
- Bill of quantities
- A priced schedule listing each item of work with its description, unit, quantity, rate, and amount; the total of the amounts gives the estimated cost.
- Single-line plumbing drawing
- A drawing in which each pipe run is shown as one line, giving the route and size but not the wall thickness; used for layout and estimation.
- Quotation versus estimate
- A quotation is a fixed price for specified work and is binding once accepted; an estimate is approximate and may change with the actual quantities and conditions.
- Tax invoice contents
- A proper tax invoice shows the supplier's name and GSTIN, invoice number and date, the customer's details, the description with HSN or SAC code, the taxable value, and the tax charged.
- Job card
- A record for each job giving the customer's name and address, the work required, materials used, labour hours, and the customer's signature on completion.
- Stop-tap leak test
- A method of locating a leak by closing the stop tap and watching the water meter; a meter that still turns with all taps closed indicates a leak on the supply side.
- Dripping tap repair
- A tap that drips at the outlet is usually cured by renewing the washer or ceramic cartridge; a drip at the spindle needs new gland packing or an O-ring.
- Pressure test of pipework
- A new water installation is tested at about 1.5 times the working pressure, held for at least an hour; any drop in pressure or visible leak fails the test.
- Die threading sequence
- Chamfer the pipe, oil it, start the die square, cut one turn forward and half a turn back to break the chip, then clean and check the thread with a gauge.
- Support spacing for pipe
- The interval between pipe brackets: about 2 metres for GI pipe up to 25 mm and about 3 metres for larger sizes; plastic pipe needs closer supports because it sags when hot.
- Wash basin fixing height