eAIS study materials
eAIS study resources

eAIS cheat sheet

eAIS · Keep the key ideas within reach.

Quick reference

Security Governance, Risk Management, and Compliance in eHealth

  • Governance triad: leadership accountability (board/CIO/CISO), documented policy hierarchy (policy → standard → procedure → guideline), and assurance (audit, metrics, third-party attestation).

  • Risk = likelihood × impact. Qualitative scales (e.g., 1–5) must be defined in a risk register with explicit acceptance thresholds and named risk owners.

  • Risk treatment options: mitigate, transfer (cyber insurance, contractual indemnity), avoid, accept. Residual risk must be formally signed off by an accountable executive.

  • Common assurance frameworks: ISO/IEC 27001 (ISMS requirements), ISO 27799 (health informatics security), NIST CSF (Identify-Protect-Detect-Respond-Recover), HITRUST CSF, SOC 2 Type II.

  • Regulatory overlap in eHealth: GDPR (EU), HIPAA Security and Privacy Rules (US), national eHealth/patient-record acts, medical-device regulation (EU MDR, US FDA premarket cybersecurity).

  • Segregation of duties: no single role should both approve and execute a change, or both administer access and audit it. Compensating controls apply where separation is impossible.

  • Key governance metrics: % critical assets with owners, % risks with treatment plans past due, audit findings closed within SLA, policy exception count and age.

  • Third-party risk: tier vendors by data sensitivity and system criticality; require security clauses, right-to-audit, breach notification timelines, and annual reassessment.

  • Compliance evidence must be retained per record-retention rules; evidence should be reproducible (configuration exports, logs, signed attestations), not narrative claims.

Quick reference

Health Information Privacy and Data Protection Law

  • GDPR lawful bases (Art. 6): consent, contract, legal obligation, vital interests, public task, legitimate interests. Health data is special category (Art. 9) and needs an additional Art. 9 condition.

  • HIPAA identifiers: 18 categories under the Safe Harbor de-identification method; the alternative Expert Determination method requires a qualified statistician's documented method.

  • Data subject rights (GDPR): access, rectification, erasure, restriction, portability, objection; response generally within one month, extendable by two further months for complex requests.

  • Breach notification clocks: GDPR - 72 hours to the supervisory authority after awareness, without undue delay to data subjects if high risk. HIPAA - 60 days from discovery for covered entities.

  • Minimum necessary principle (HIPAA) and data minimization (GDPR Art. 5) both limit collection, use, and disclosure to what the purpose requires.

  • Privacy by design and by default: data protection impact assessment (DPIA) is required for high-risk processing such as large-scale health data or systematic monitoring.

  • Roles: controller determines purpose and means; processor acts on documented instructions. A processor that exceeds instructions becomes a controller for that processing.

  • Cross-border transfers need a valid mechanism: adequacy decision, standard contractual clauses, binding corporate rules, or derogation. Schrems II requires transfer impact assessment.

  • Patient consent in eHealth must be specific, informed, granular, and revocable; consent records must capture version, timestamp, scope, and withdrawal.

Quick reference

Access Control, Identity Management, and Authentication

  • Access control models: DAC (owner discretion), MAC (labels/clearance), RBAC (role → permission), ABAC (attributes: user, resource, environment, purpose). Healthcare often uses ABAC or RBAC with break-glass.

  • Authentication factors: something you know, have, are. MFA requires factors from at least two different categories; two passwords are not MFA.

  • NIST SP 800-63B: memorized secrets should be at least 8 characters, checked against breached-password lists, and not forced into periodic rotation absent compromise evidence.

  • FIDO2/WebAuthn and passkeys are phishing-resistant authenticators; SMS OTP is vulnerable to SIM swap and interception.

  • Identity lifecycle: joiner-mover-leaver. Access must be provisioned on approved request, re-evaluated on role change, and revoked promptly on termination.

  • Least privilege and need-to-know: clinical staff access only the records required for the current care episode; access is logged and auditable.

  • Break-glass (emergency access) must be time-limited, reason-coded, alerted in real time, and reviewed retrospectively.

  • Privileged access management: separate admin accounts, just-in-time elevation, session recording, vaulted credentials, no shared generic accounts.

  • Periodic access recertification: managers attest to entitlements at defined intervals; orphaned and dormant accounts are disabled per policy.

Quick reference

Network Security and Infrastructure Protection

  • Segmentation: separate clinical device VLANs, medical IoT, guest, and corporate networks; enforce inter-zone traffic via firewalls with default-deny rules.

  • Zero trust principles: verify explicitly, least-privilege access, assume breach. Identity and device posture drive access, not network location alone.

  • TLS 1.2 minimum, TLS 1.3 preferred; disable SSLv3, TLS 1.0/1.1. Use strong cipher suites and HSTS for web-facing services.

  • VPN and remote access: strong authentication (MFA), split vs full tunnel decision, and endpoint posture checks before granting access.

  • Wireless: WPA2-Enterprise or WPA3 with 802.1X; separate SSIDs for clinical devices, staff, and guests.

  • DNS and email defenses: SPF, DKIM, DMARC for domain protection; DNS filtering to block known malicious infrastructure.

  • IDS/IPS placement: network sensors at perimeter and key internal chokepoints; alert tuning to reduce false positives in clinical environments.

  • Infrastructure hardening: disable unused services/ports, change default credentials, patch firmware on medical devices per vendor-coordinated schedule.

  • Network documentation and inventory: asset register with owner, location, firmware version, and network zone is prerequisite for effective segmentation.

Quick reference

Endpoint, Application, and Software Security

  • EDR capabilities: behavioral detection, process lineage, isolation, rollback, and threat hunting. Signature-only AV is insufficient against fileless and ransomware attacks.

  • Patch management SLA tiers: critical vulnerabilities typically remediated within days (e.g., 14 days), high within 30, medium within 90 - defined per organizational policy.

  • Secure SDLC: threat modeling at design, static analysis (SAST) in code, dynamic analysis (DAST) in test, dependency scanning (SCA) for third-party libraries.

  • OWASP Top 10 categories include broken access control, injection, cryptographic failures, insecure design, security misconfiguration, and vulnerable components.

  • Input validation and output encoding prevent injection; parameterized queries are the primary defense against SQL injection.

  • Medical device software: FDA premarket cybersecurity requires SBOM, vulnerability management plan, and coordinated disclosure; EU MDR requires similar evidence.

  • SBOM (Software Bill of Materials) formats: SPDX and CycloneDX; enables rapid identification of affected components when a CVE is published.

  • Application hardening: disable debug modes, enforce secure headers (CSP, X-Content-Type-Options), remove default accounts, and enforce session timeouts.

  • Endpoint encryption (full-disk) and application allowlisting reduce data loss from lost devices and unauthorized execution on clinical workstations.

Quick reference

Cryptography and Secure Health Data Exchange

  • Symmetric encryption (AES-256) for data at rest and bulk data in transit; asymmetric (RSA ≥ 2048-bit or ECC P-256+) for key exchange and digital signatures.

  • Hashing (SHA-256 or stronger) provides integrity, not confidentiality; passwords must use salted, slow hashes (bcrypt, scrypt, Argon2), never plain SHA.

  • Digital signatures provide authenticity, integrity, and non-repudiation; they rely on a trusted certificate chain and private-key protection.

  • PKI components: CA, registration authority, certificate lifecycle (issue, renew, revoke), CRL/OCSP for revocation checking.

  • HL7 FHIR security: OAuth 2.0 / SMART on FHIR for authorization, TLS for transport, and resource-level scopes for access control.

  • Key management lifecycle: generation, distribution, storage (HSM preferred), rotation, archival, destruction. Key rotation limits exposure window from compromise.

  • Interoperability security: HL7 v2, CDA, and FHIR exchanges must be authenticated, encrypted, and auditable; mTLS is common for system-to-system exchange.

  • Crypto agility: design systems to swap algorithms without re-architecture, given deprecation of legacy algorithms (SHA-1, RSA-1024, 3DES).

  • Data in use protection: confidential computing and enclaves protect health data during processing; tokenization reduces exposure of identifiers.

Quick reference

Security Operations, Monitoring, and Incident Response

  • SIEM function: log aggregation, correlation, alerting, and retention. Critical log sources include identity providers, EDR, firewalls, EHR audit logs, and cloud control planes.

  • Incident response phases (NIST SP 800-61): preparation; detection and analysis; containment, eradication, recovery; post-incident activity.

  • Severity classification drives escalation: define P1 (patient safety or active ransomware) through P4, with response-time SLAs and notification paths.

  • Healthcare-specific incident triggers: EHR downtime, medical device compromise, unauthorized PHI access, ransomware with encryption, and third-party breach.

  • Forensics: preserve volatile data first (memory, network connections), maintain chain of custody, and use write-blockers for disk imaging.

  • Detection coverage: map telemetry to MITRE ATT&CK techniques to identify blind spots; healthcare attacks frequently use phishing, RDP exposure, and valid-account abuse.

  • Threat intelligence and IOC feeds improve detection but must be tuned to avoid alert fatigue in 24/7 clinical operations.

  • Post-incident review: root cause analysis, corrective actions with owners and due dates, and lessons-learned updates to playbooks.

  • Regulatory reporting must be coordinated with legal/privacy; the technical response and the notification obligation run in parallel, not sequentially.

Quick reference

Business Continuity, Disaster Recovery, and Backup

  • RTO = maximum acceptable downtime; RPO = maximum acceptable data loss (measured in time). Both are set by business impact analysis, not by IT preference.

  • BIA output: critical clinical services ranked, dependencies mapped, and minimum service levels defined for degraded operation.

  • Backup 3-2-1 rule: at least 3 copies, on 2 different media, with 1 offsite or offline/immutable.

  • Ransomware resilience requires immutable or air-gapped backups and tested restore procedures; backups reachable from the domain are at risk.

  • EHR downtime procedures: paper forms, read-only backup access, and defined re-synchronization steps when systems return.

  • DR testing types: tabletop, simulation, partial failover, full failover. Untested plans are assumptions, not controls.

  • Recovery tiers: hot site (near-zero RTO), warm site (hours to days), cold site (days to weeks). Selection depends on BIA criticality.

  • Backup verification: restore tests at defined intervals, integrity checks, and documented evidence of successful recovery.

  • Crisis communications: pre-defined contact trees, patient-safety escalation, and public/regulator communication templates.

Quick reference

Emerging Technology and Security Awareness in Healthcare

  • AI/ML in healthcare: risks include model poisoning, data leakage in training, bias, and lack of explainability. Governance requires model inventory, validation, and monitoring.

  • LLM usage policy: prohibit entering PHI into unapproved public generative-AI tools; approved tools must have contractual data protections.

  • IoT and medical device security: inventory, network isolation, default-credential removal, firmware patching, and vendor security requirements in procurement.

  • Cloud shared responsibility: provider secures infrastructure; customer secures identity, configuration, data classification, and access. Misconfiguration is a leading breach cause.

  • Telehealth security: end-to-end encryption, authenticated sessions, secure recording storage, and consent capture for remote consultations.

  • Security awareness effectiveness: measure via phishing simulation click rates, report rates, and time-to-report - not completion percentages alone.

  • Social engineering in healthcare exploits urgency and authority (e.g., fake clinician requests for records); verification procedures must be defined and rehearsed.

  • Supply chain and third-party risk: require SBOM, vulnerability disclosure, and security attestations for connected medical devices and SaaS.

  • Emerging regulation: AI Act (EU) risk classification, medical device software guidance, and national cybersecurity directives for critical health infrastructure.