CCPIA flashcards
CCPIA · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Live load
- The load imposed by occupancy and use, such as people, furniture, and movable equipment. ASCE 7 lists typical values: 50 psf for offices, 100 psf for corridors, and 125 psf for storage.
- Dead load
- The permanent, static weight of the structure itself, including framing, finishes, roofing, and fixed equipment. It is calculated from material densities and remains constant over the life of the building.
- L/360 deflection
- A common serviceability limit for floor members under live load, meaning the maximum deflection equals the span divided by 360. Roof members are often limited to L/240.
- Thermal bridging
- Heat flow through continuous, highly conductive framing that bypasses insulation, causing cold spots and condensation. Continuous exterior insulation or thermal breaks reduce the effect.
- Air barrier continuity
- An uninterrupted plane that resists air leakage across the envelope. It must be sealed at penetrations and at roof, wall, and foundation transitions, where most leakage occurs.
- Positive drainage
- Roof design that moves water to drains or scuppers without ponding. Standing water remaining 48 hours after rain indicates inadequate slope or deflected structure.
- Roof cricket
- A small sloped ridge installed on the uphill side of a chimney or large rooftop unit to divert water around the obstruction and prevent ponding and debris accumulation.
- Base flashing height
- The upturned membrane or flashing at a roof-to-wall junction, typically at least 8 inches above the roof surface, with counterflashing lapped over its top edge.
- Ponding water
- Water that remains on a roof more than 48 hours after rainfall. It signals inadequate slope, clogged drains, or structural deflection and can lead to membrane failure and overload.
- Infrared moisture survey
- A thermographic scan that reveals wet roof insulation as temperature anomalies after sunset. It is a screening tool; nuclear or impedance meters confirm suspect areas.
- Trap seal
- The water barrier in a plumbing trap, typically 2 to 4 inches deep, that prevents sewer gas from entering the building. Evaporation from disuse can break the seal.
- T&P relief valve
- A temperature and pressure safety valve on a water heater, mounted within the top 6 inches of the tank, with a full-size discharge pipe terminating 6 to 24 inches above the floor.
- GFCI protection
- Ground-fault circuit interrupter protection required at bathrooms, kitchens, garages, outdoors, and within 6 feet of sinks. It trips at a small current imbalance to prevent shock.
- Plenum-rated cable
- Cable listed for installation in an air-handling plenum, with low smoke and flame spread. It is required by NFPA 90A unless the cable is enclosed in metal conduit.
- Phase I elevator recall
- Automatic recall of elevators to the designated landing when a lobby, machine room, or hoistway smoke detector activates, removing the car from the fire floor.
- Demising wall
- The wall separating one tenant space from another or from common areas. In core-and-shell inspections, it commonly marks the boundary of the inspector's scope.
- Accessible route
- A continuous path connecting accessible elements, with a minimum 36-inch clear width, running slope no steeper than 1:20, and cross slope no steeper than 1:48.
- Van-accessible space
- A parking space with an adjacent 96-inch access aisle, required for one of every six accessible spaces, with a maximum slope of 1:48 in all directions.
- Curb ramp slope
- The maximum running slope for a curb ramp is 1:12, with flared sides no steeper than 1:10. Detectable warning surfaces mark the transition to the street.
- Trip hazard threshold
- A vertical change in walking surface over 1/4 inch is a trip hazard. Displacement over 1/2 inch requires a beveled edge or replacement of the section.
- Egress width factor
- The IBC occupant load multiplier for egress capacity: 0.2 inch per occupant on level components and 0.15 inch per occupant on stairs, with minimum widths by occupancy.
- Travel distance limit
- The maximum distance from the most remote point to an exit. It is 250 feet for nonsprinklered business occupancy and 300 feet when sprinklered, subject to local amendment.
- Class K extinguisher
- A wet-chemical extinguisher for cooking media fires, required in commercial kitchens with deep fryers. Maximum travel distance to the extinguisher is typically 30 feet.
- Smoke detector spacing
- On a flat ceiling, detectors are placed within 21 feet of any wall, with spacing set by the manufacturer and NFPA 72. They are kept at least 3 feet from supply diffusers.
- Self-closing fire door
- A door in a rated assembly that closes and latches automatically after each use. Propping or removing the closer defeats the fire separation and is a reportable deficiency.
- Representative sampling
- Inspecting a documented subset of repeated components, such as a portion of windows or outlets, and stating the sample size and method in the report.
- Observed condition language
- Report wording that describes what was seen rather than speculating about cause. Causation is stated only when directly observable, such as a stain below a visible roof defect.
- Standard of care
- The level of care a reasonably competent inspector would exercise under similar circumstances. It is a performance standard, not a warranty against future failure.
- Conflict of interest
- A situation in which the inspector benefits from repair work identified in the report, such as a referral fee. It must be avoided to preserve objectivity and client trust.
- Scope of work
- The systems and components the inspector agrees to examine. It must meet the applicable standard of practice and disclose any exclusions or limitations before the inspection.
- Errors and omissions insurance
- Professional liability coverage for claims of negligent inspection or reporting. It is typically claims-made, so the retroactive date and prior-acts coverage matter.
- Limitation of liability clause
- A contract provision capping damages, often at the inspection fee. Enforceability varies by state, and some jurisdictions limit or prohibit such caps.