InterNACHI Pool & Spa Inspector study materials
InterNACHI Pool & Spa Inspector study resources

InterNACHI Pool & Spa Inspector cheat sheet

InterNACHI Pool & Spa Inspector · Keep the key ideas within reach.

Quick reference

Pool and Spa Inspection

  • Water turnover time equals total volume divided by flow rate; residential pools are commonly designed for roughly a 6-8 hour turnover, and a longer measured turnover signals undersized pump, clogged filter, or restricted suction lines.

  • A skimmer equalizer line or a second low suction outlet (anti-vortex/anti-entrapment cover) is the standard safeguard against full suction at a single blocked skimmer; absence of either is a reportable entrapment hazard.

  • Virginia Graeme Baker Act compliance requires an anti-entrapment drain cover rated for the pump's flow; a missing, cracked, or unlabeled cover on any submerged suction outlet is an immediate hazard, not a maintenance note.

  • Maximum suction outlet velocity for a VGB-compliant cover is 1.5 ft/sec for a single outlet; when two outlets are tied together the design assumes one becomes blocked, so the cover must handle the full pump flow.

  • A working pressure gauge on the filter plus a flow meter allows calculation of system head; a filter pressure rise of 8-10 psi above clean baseline indicates the filter needs backwashing or cleaning.

  • Barrier requirements: a 4-foot minimum height barrier with no footholds, self-closing and self-latching gate opening outward with latch at least 54 inches above grade, and no direct house door opening to the pool without an alarm or safety cover.

  • Entrapment hazards to check and report: missing drain covers, broken skimmer equalizer covers, single-blockable outlets, exposed suction pipe, and loose or deteriorated plaster that can hide a broken cover screw.

  • Deck and safety features: slip-resistant deck surface, deck slope draining away from the pool, no trip hazards at coping joints, and a reach pole or ring buoy within sight of the water at all times.

  • Electrical: all pool equipment must be on GFCI protection, bonded with an equipotential bonding grid, and no overhead conductors within the required clearances over the water surface; report any missing bond wire at the pump.

Quick reference

Pool and Spa Inspection

  • Sanitizer residuals: free chlorine typically 1-3 ppm (cyanuric acid-stabilized pools need higher free chlorine per the CYA/FC chart), bromine 3-5 ppm, and pH 7.2-7.8; report measured values without certifying chemical safety.

  • Total alkalinity 80-120 ppm buffers pH; calcium hardness 200-400 ppm protects plaster; cyanuric acid above roughly 50-100 ppm reduces chlorine effectiveness and is a common finding in outdoor pools.

  • Saturation index (Langelier) uses pH, temperature, calcium hardness, total alkalinity, and total dissolved solids; a negative index etches plaster and a positive index scales it, so record the inputs rather than the verdict alone.

  • Spa chemistry runs hotter and evaporates faster: a spa at 104°F is the maximum safe setpoint, and the small water volume means sanitizer and pH swing much faster than in a pool.

  • A spa's air blower and venturi jets introduce air, raising pH over time; combined chlorine (chloramines) above 0.5 ppm produces the 'chlorine smell' and indicates the need to shock or drain.

  • Inspect the spa's safety suction fitting, the heater's pressure switch and high-limit switch, and the GFCI at the spa disconnect; a spa without a functioning high-limit is a scald and fire risk.

  • Heater and equipment pad: check for gas leaks at unions, a sediment trap on the gas line, proper combustion air, and a check valve preventing hot water backflow into a spa's PVC plumbing.

  • Backflow and cross-connection: an autofill line needs an air gap or vacuum breaker, and a hose bib at the pad needs a backflow preventer to protect the potable supply.

  • Document water clarity, visible algae, staining, scale lines, and the presence of a main drain grate; these are observable conditions, while chemistry testing is a snapshot that must be reported as such.