Inspecting a Buried-Lid Steel Tank on an Occupied Property

InterNACHI Septic · Put your knowledge to work in context.

All case studies

Inspecting a Buried-Lid Steel Tank on an Occupied Property

A 1978 ranch house has a 1,000-gallon steel septic tank with two 24-inch lids buried about 12 inches below grade. There are no risers. The homeowner reports slow drains but will not pump the tank before the inspection because 'it was pumped three years ago.' The inspector has a shovel, a steel probe, a four-gas meter, and a flashlight. The tank is within 10 feet of the foundation and under a wooden deck; the drainfield is in the front yard. The electrical disconnect for the pump, if any, is not labeled. It is a warm day, and the ground over the tank is soft. The homeowner wants a 'full certification' that the system is in good working order. The inspector has no camera or sludge judge.

1. Describe a safe inspection sequence and the limitations you would state.

Read the worked answer

Start by defining the scope and the homeowner's refusal to pump. Locate the tank with a probe using light hand tools, avoiding the house foundation and any buried utilities. Before opening, use the four-gas meter and stand upwind; keep flames and smoking away. Wear gloves and eye protection. On a steel tank, do not stand or kneel on the lid; use a lid hook and assume the lid or tank top may be corroded. Never enter the tank. Observe water level relative to the outlet, baffle condition, corrosion, and evidence of backup. Because there is no sludge judge, do not estimate sludge and scum depth; state that limitation. Check for surfacing or odor at the drainfield. Do not open electrical enclosures; if a pump disconnect is present but unlabeled, recommend evaluation by an electrician or septic contractor. Run water inside to observe flow. Record soft ground and deck loading as access constraints.

2. How should the inspector respond to the request for a 'full certification'?

Read the worked answer

Explain that a visual, non-invasive inspection cannot certify that the system is in good working order. Without pumping, the inspector cannot measure sludge and scum, inspect the tank bottom, or verify the outlet and inlet baffles fully. A steel tank from 1978 may have thin or perforated walls that are not visible from the top. Without a camera, the inspector cannot verify the condition of the inlet and outlet pipes or the distribution box. Offer an inspection report that lists observed conditions and deficiencies, states the limitations, and recommends pumping and evaluation by a licensed septic contractor. Do not use the word 'certified.' If the homeowner insists, decline to provide a certification beyond the scope and document the refusal in writing.

3. What defects would you specifically look for given the tank type and burial conditions?

Read the worked answer

Look for corrosion perforations, a collapsed or bowed lid, a rusted tank top, deteriorated inlet or outlet baffles, root intrusion at the lid, and a water level above the outlet. Check for evidence of recent backup, such as staining or toilet-paper marks at the inlet. Verify that lids are secure and that buried lids without risers create a access and safety deficiency. Check that the tank is not holding water above the outlet and that the outlet is not blocked. At the drainfield, look for wet spots, odors, and lush strips. Note the unlabeled electrical disconnect as a safety defect requiring labeling and evaluation. Report soft ground and the deck as access limitations, and recommend risers to grade for future maintenance and safe access.