InterNACHI Stucco/EIFS Inspector flashcards
InterNACHI Stucco/EIFS Inspector · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Scratch coat thickness
- The first coat of three-coat portland cement stucco, nominally about 3/8 inch thick, applied over lath or masonry and scored to provide a key for the brown coat.
- Brown coat purpose
- The second coat of three-coat stucco, nominally 3/8 inch thick, applied over the cured scratch coat to build thickness, provide a level plane, and receive the finish coat.
- Weep screed function
- A metal base screed with weep holes installed at the bottom of stucco walls to allow incidental water to drain out from behind the stucco and to provide a straight termination.
- Metal lath furring
- Self-furred lath or furring fasteners hold metal lath at least 1/4 inch off the sheathing so stucco can key through the openings and embed the lath completely.
- Control joint spacing
- Keyed or surface control joints in stucco are typically spaced about 10 to 15 feet in each direction and placed at substrate changes, corners, and penetrations to control cracking.
- Casing bead use
- A metal accessory with a flange used to terminate stucco at openings and penetrations, providing a straight edge and a joint line for sealant without crushing the lath furring.
- Water-resistive barrier laps
- The WRB behind stucco is lapped shingle-fashion so upper courses overlap lower courses, keeping water flowing outward and downward rather than behind the barrier.
- Barrier EIFS definition
- An EIFS assembly with no drainage cavity that relies on the sealed face lamina to prevent water entry; a breach in the finish or sealant admits water behind the insulation.
- Drainage EIFS components
- A water-managed EIFS with a WRB, a drainage plane, grooved or notched insulation forming a cavity, and a base drainage track or weep detail to discharge water.
- EIFS lamina definition
- The outer EIFS layers consisting of reinforced base coat and textured finish coat over EPS insulation; the lamina provides weather resistance and appearance but is not structural.
- Mesh embedment
- Alkali-resistant fiberglass mesh is embedded in the base coat with specified laps, typically at least 2.5 inches, and backwrapped at terminations to reinforce the lamina.
- EPS board joints
- Insulation board joints in EIFS must be tight and offset from substrate joints; gaps wider than about 1/16 inch are filled to keep the lamina flat and continuous.
- Backwrapping EIFS
- Folding the reinforcing mesh around the edge of the insulation at terminations and openings so the base coat wraps the edge, protecting the lamina from water and impact.
- Sealant joint limitation
- Sealant at EIFS penetrations and windows is a secondary seal; it does not replace flashing, and failed sealant is a common water entry path in barrier systems.
- Four water entry paths
- Common stucco and EIFS water entry points are penetrations, terminations, horizontal ledges, and cracks or failed sealant, each requiring a flashing or drainage remedy.
- Wood moisture threshold
- Elevated sheathing moisture in stucco or EIFS walls is often flagged at roughly 16 to 20 percent wood moisture content, confirmed by probing or destructive testing.
- Kick-out flashing
- A flashing at the bottom of a roof-to-wall intersection that diverts roof water away from the wall; it must extend above the roof and project past the wall face.
- Sill pan flashing
- Flashing installed under a window or door sill, with a sloped sill and back dam, to collect and drain water that enters at the opening instead of relying on sealant.
- Weep screed clearance
- The weep screed should sit at least 4 inches above grade or 2 inches above paved surfaces so the drainage path stays open and the stucco base does not stay wet.
- Diagonal crack significance
- Diagonal cracks radiating from the corners of openings suggest stress concentration or movement and warrant further evaluation, unlike fine random shrinkage map cracking.
- Efflorescence meaning
- A white salt deposit on stucco or masonry that indicates water has moved through the assembly and evaporated at the surface; it is evidence of moisture, not the cause.
- Shingle-fashion flashing
- The rule that upper layers overlap lower layers so water flows down and out; the WRB laps over the top flange of flashing and head flashing laps jamb flashing.
- Window flashing sequence
- At an opening, install sill flashing first, then jamb flashing, then head flashing with a drip edge and end dams so water is directed out and over the layers below.
- Deck ledger flashing
- A Z-flashing or spacer at a deck ledger keeps the ledger off the stucco and directs water away, preventing trapped moisture at the wall-to-deck connection.
- Penetration flashing rule
- Penetrations such as hose bibs and vents need a flanged, sealed flashing that laps the WRB above and is sealed at the face; sealant alone is not an acceptable flashing.
- Roof-to-wall termination
- At a roof-to-wall junction, the wall WRB laps over the roof flashing and the stucco terminates above the roof with a weep screed or casing bead and sealant joint.
- Chimney chase flashing
- A chimney chase or bump-out needs a cricket or diverter at the top and base flashing with a drainage path at the bottom to shed water away from the stucco.
- Identify system before inspection
- Determine whether the wall is three-coat stucco, one-coat stucco, barrier EIFS, or drainage EIFS before judging compliance, because requirements differ by system.
- Concealed work verification
- Substrate, WRB, lath, flashing, and weep screed must be inspected before they are covered by subsequent coats, since defects cannot be seen afterward.
- Moisture meter grid
- Take moisture readings on a regular grid across suspect walls and record location, date, and meter mode; confirm elevated readings with a second method or probe.
- Delamination sounding test
- Tapping the stucco or EIFS lamina with a sounding tool; a hollow sound indicates separation from the substrate and is a reportable defect requiring evaluation.
- Report condition versus opinion
- A report should state the observed condition and measurement, cite the applicable requirement, and recommend specialist evaluation, clearly separating observation from inferred cause.