Fukushima Entrance Science · Put your knowledge to work in context.

All case studies

Treating Metal-Laden Groundwater at a School Well

A school well beside a former metal-plating workshop is used for irrigating a vegetable garden. Laboratory analysis reports Ni²⁺ 0.08 mg/L, Cu²⁺ 0.30 mg/L, pH 5.8, alkalinity 10 mg/L as CaCO₃, and dissolved oxygen 6 mg/L. The local irrigation guideline is 0.20 mg/L for both Ni and Cu, so only Cu exceeds. Available materials are a 20 kg bag of activated carbon, 25 kg of ground CaCO₃, 1 L of 1.0 M NaOH, and a cation-exchange column rated for 500 bed volumes before breakthrough. A vendor proposes passing the water through activated carbon and adding HCl to pH 4.5 to 'keep the metals dissolved and prevent scaling.' The chemistry club must judge the proposal, propose a safer treatment train, and say what should be measured before water is used. Ksp values: Ni(OH)₂ = 5.5×10⁻¹⁶; Cu(OH)₂ = 2.2×10⁻²⁰.

1. Evaluate the vendor's proposal using the chemistry of the metals and the guideline values. Include at least one quantitative check at pH 5.8 or at the proposed pH 4.5.

Read the worked answer

Activated carbon is mainly useful for dissolved organic compounds; it is a poor primary treatment for ionic Cu²⁺ and Ni²⁺. Acidifying to pH 4.5 does the opposite of removal: it increases metal solubility and mobility. At pH 4.5, [OH⁻] = 10⁻⁹·⁵ = 3.16×10⁻¹⁰ M. For Cu, 0.30 mg/L = 0.30/63.55 = 4.72×10⁻⁶ M, so the ion product is (4.72×10⁻⁶)(3.16×10⁻¹⁰)² = 4.7×10⁻²⁵, far below Ksp = 2.2×10⁻²⁰. Ni is even further below its Ksp. No hydroxide precipitation is expected, so the acidified water would carry Cu through the system. At the existing pH 5.8, [OH⁻] = 6.3×10⁻⁹ M, and the Cu ion product is about 1.9×10⁻²², still undersaturated. The proposal should be rejected: it does not remove Cu and may increase the amount reaching the garden.

2. Design a treatment train that would bring Cu below 0.20 mg/L and keep Ni below its guideline. State the pH target, the role of each unit, and a monitoring plan.

Read the worked answer

Raise pH to about 8.5–9.0 with ground CaCO₃, using NaOH only for fine adjustment. At pH 9.0, [OH⁻] = 1.0×10⁻⁵ M, so the Cu ion product is (4.72×10⁻⁶)(1.0×10⁻⁵)² = 4.7×10⁻¹⁶, vastly above Ksp = 2.2×10⁻²⁰; Cu(OH)₂ should precipitate. For Ni, (1.36×10⁻⁶)(1.0×10⁻⁵)² = 1.36×10⁻¹⁶, slightly below Ksp = 5.5×10⁻¹⁶, so Ni is not fully removed but is already below its 0.20 mg/L guideline. Let the precipitate settle or filter it, then polish with the cation-exchange column to capture residual Ni and Cu. The column's 500-bed-volume rating is finite, so track throughput and regenerate or replace it before breakthrough. Monitor pH, Cu, Ni, alkalinity, and turbidity after each batch; do not irrigate until Cu is below 0.20 mg/L and pH is in an agronomically acceptable range. Dispose of metal-bearing sludge as hazardous or controlled waste, not on the garden.