Engineer Electric Railway flashcards
Engineer Electric Railway · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- 12-pulse rectifier
- A traction rectifier using two six-pulse bridges fed by transformer secondaries displaced 30 degrees; series connection cancels the 5th and 7th harmonic currents on the AC side.
- Traction voltage classes
- Common nominal systems are 750 V DC, 1500 V DC and 3000 V DC, plus 15 kV 16.7 Hz AC and 25 kV 50 Hz or 60 Hz AC; voltage tolerances are defined by standards.
- Rectifier no-load voltage
- For a three-phase full bridge, ideal average DC voltage equals 1.35 times the secondary line-to-line RMS voltage; a 12-pulse series arrangement doubles that value when both bridges have equal input.
- Regenerative receptivity
- The ability of the traction supply to accept braking energy; it depends on nearby train load, reversible substations or energy storage, and catenary voltage limits that trigger brake resistors.
- Contact wire stagger
- A deliberate horizontal zigzag, typically plus or minus 200 to 300 mm, that spreads pantograph carbon wear across the strip and avoids a fixed contact point on the wire.
- Catenary sag formula
- For a level span with uniform weight w and tension T, midspan sag D is approximately w times span squared divided by eight times T; pre-sag compensates live load.
- Neutral section
- A short de-energized catenary section separating adjacent feeding zones; trains coast through it, and the pantograph must not bridge both sides unless the design permits.
- Pantograph contact force
- The vertical force between pantograph and contact wire, commonly 60 to 120 N static; dynamic variation must remain bounded to prevent contact loss and arcing at speed.
- Constant flux region
- Below base speed, traction inverters keep voltage-to-frequency ratio approximately constant, producing high torque; above base speed field weakening reduces flux and available torque.
- Regenerative braking
- Traction motors act as generators, and the inverter returns energy to the DC link; energy is reused, stored, or dissipated in brake resistors when the line cannot accept it.
- Auxiliary static inverter
- Converts the DC link or battery voltage to three-phase AC for cooling fans, compressors, lighting and control loads; redundant modules and battery backup preserve essential functions.
- Brake blending
- Coordination of regenerative or dynamic braking with friction brakes so total braking effort meets the demand while respecting adhesion limits and minimizing pad wear.
- Track circuit
- A failsafe train detection circuit using running rails as conductors; train axles short the rails, dropping a relay or receiver and indicating occupancy to the interlocking.
- Approach locking
- Interlocking protection that prevents a signal from being cancelled after a train has passed the approach track, forcing the route to be completed or timed out.
- Movement authority
- Permission for a train to proceed to a defined limit, issued by ATP or the signaler; ATP enforces braking curves so the train stops before the limit.
- Grade of automation
- GoA 1 to 4 classify train operation from manual driving with ATP supervision to unattended automatic operation, covering door control, departure and obstacle detection.
- GSM-R
- A railway mobile radio standard based on GSM, providing voice and data for train control and operations; it is being succeeded by FRMCS in new deployments.
- SCADA RTU
- Remote terminal unit at a substation or facility that acquires status and analog measurements, executes commands, and exchanges telemetry with the control center.
- IEC 60870-5-104
- A telecontrol protocol that carries SCADA messages over TCP/IP, commonly used between railway control centers and remote terminal units for monitoring and control.
- Telecom ring protection
- A fiber transmission ring that reroutes traffic after a link failure, typically within 50 ms, preserving signaling, radio and SCADA communications.
- Stray current corrosion
- DC traction current returning through earth instead of rails causes electrolytic corrosion at buried metal; mitigation uses insulated rails, return bonding, drainage and potential monitoring.
- Surge arrester
- A voltage-dependent device, commonly zinc oxide, that clamps transient overvoltages and diverts surge current to ground, then reseals after the impulse.
- Rail potential
- The voltage between running rails and earth; it must be limited because touch voltages endanger people and elevated potentials drive stray current into buried structures.
- EN 50121
- The European railway electromagnetic compatibility standard series, covering emissions and immunity for rolling stock, infrastructure and signaling equipment.
- Protection selectivity
- Coordination so the protective device nearest a fault trips first, isolating the smallest possible section while upstream devices remain closed for downstream faults.
- DC feeder di/dt protection
- A traction protection that detects the rapid initial current rise of a short circuit; it trips faster than overcurrent thresholds that must ride through train starting current.
- Earth fault protection
- Detection of current flowing from live conductors to earth through insulation failure; it trips the circuit breaker or alarms, depending on system earthing and safety policy.
- Breaking capacity
- The maximum short-circuit current a circuit breaker can interrupt safely at its rated voltage; it must exceed the calculated prospective fault current at the installation point.
- Condition-based maintenance
- Maintenance triggered by measured condition such as wear, temperature, or partial discharge, rather than fixed intervals, reducing unnecessary work while preventing failures.
- Contact wire wear measurement
- Periodic measurement of remaining contact wire cross-section, often by laser or mechanical gauge, compared with limits to schedule renewal before tensile strength is lost.
- Insulation resistance test
- A DC voltage test measuring leakage current to derive insulation resistance; results are compared with minimum values and previous trends to detect moisture or degradation.
- ISO 55000
- An international standard for asset management, defining principles for aligning asset portfolios with organizational objectives, risk, lifecycle cost and performance.