Fire tetrahedron
A model connecting fuel, oxidizer, heat and sustained chemical chain reaction in the explanation of combustion.
Flash point
The lowest temperature under a specified test at which a liquid produces vapor that can ignite with an external source.
Autoignition
Ignition without a separate flame or spark under the relevant material and environmental conditions being considered.
Convection
Heat transfer associated with fluid motion, important when hot smoke and gases move through building spaces.
Thermal radiation
Transfer of energy by electromagnetic radiation, allowing a fire to heat surfaces without direct flame contact.
Flashover
A rapid transition toward widespread compartment involvement associated with thermal feedback, whose occurrence depends on the actual conditions.
Wet-pipe sprinkler
A sprinkler arrangement with water normally present in the distribution piping, distinct from dry-pipe or preaction configurations.
Preaction arrangement
A system configuration using a defined detection and valve sequence before discharge, whose actual logic depends on the approved design.
Flow rate
The volume of fluid passing a point per unit time, distinct from pressure or total stored volume.
Pressure loss
The reduction in fluid pressure associated with specified flow and system conditions, including friction and relevant fittings.
Trouble signal
An indication of a fault or abnormal system condition that should be distinguished from a fire alarm indication.
Impairment
A condition in which a protection system or part of it cannot provide its intended function until appropriately restored.
Legal basis
The applicable statutory authority needed for an administrative action, especially where rights are restricted or obligations imposed.
Proportionality
Assessment of suitability, necessity and the balance between the public purpose and the burden imposed on affected persons.
Administrative guidance
A noncoercive administrative communication or recommendation whose legal character differs from an enforceable disposition.
Disposition
An administrative exercise or refusal of public authority with legally relevant effects, assessed under the applicable Korean procedural framework.
Oxidizer
A material capable of supporting or intensifying combustion under relevant conditions, requiring compatibility assessment with other stored substances.
Water-reactive material
A substance that can generate hazardous heat or products on contact with water, requiring material-specific handling and response controls.
Flammable range
The interval of fuel concentration that can support flame propagation under specified test and environmental conditions.
Designated-quantity multiple
The dimensionless ratio of a stored material quantity to its applicable designated reference quantity under the stated classification.