- Stoichiometric air for methane
- About 9.52 m³ of air per m³ of methane at standard conditions, because 1 m³ CH4 needs 2 m³ O2 and air is 21 % oxygen.
- Wobbe index
- The calorific value divided by the square root of relative density. It characterises the heat input delivered through a fixed orifice at fixed pressure.
- Methane flammability limits
- Roughly 5 % to 15 % methane by volume in air. Below the lower limit the mixture is too lean to ignite; above the upper limit it is too rich.
- HHV versus LHV
- HHV includes the latent heat recovered from condensing water vapour in the products; LHV excludes it. Natural gas HHV is about 11 % higher than LHV.
- CO/CO2 ratio
- A combustion quality indicator. For natural gas a ratio below 0.004 indicates clean combustion; higher values suggest incomplete combustion and carbon monoxide formation.
- Relative density of natural gas
- About 0.6 compared with air, so natural gas rises and collects at high points, unlike LPG vapour which is heavier than air and settles low.
- MOP and MAOP
- Maximum operating pressure is the pressure at which a system may normally operate; maximum allowable operating pressure is the design limit set by the weakest component rating.
- Monitor regulator function
- A second regulator in series that takes over if the active regulator fails, limiting downstream pressure to a safe value and protecting connected equipment and pipework.
- Purge volume rule
- Displacing air from gas pipework typically requires two to five pipe volumes of gas, confirmed by measuring gas concentration at the purge outlet.
- Odorisation target
- Gas must be odorised so it is detectable at about one fifth of the lower explosive limit, commonly achieved with tetrahydrothiophene at 10–20 mg/m³.
- Type C appliance
- A room-sealed appliance that takes combustion air from outside and discharges products outside through a balanced flue, so it is independent of room air.
- Flame rectification sensing
- A flame ionises gas and conducts a small current between electrode and burner. Loss of flame breaks the circuit and the control shuts the gas valve.
- Gas valve class A
- A multiblock valve class with the tightest closing requirement, used where downstream leakage is critical or appliance input exceeds about 120 kW.
- Appliance turndown ratio
- Maximum rated input divided by minimum stable input. Higher turndown improves part-load efficiency but can destabilise the flame and raise carbon monoxide.
- Combustion air free area
- Open-flue appliances typically need about 5 cm² of permanent free ventilation per kW of input, measured as free area rather than grille dimensions.
- Draught diverter spillage
- Smoke or products escaping at the diverter indicates blocked flue, inadequate combustion air, or adverse pressure, and the appliance must be shut down.
- Balanced flue terminal clearance
- Terminals must be kept clear of openings, boundaries, and mechanical extractor terminals, typically at least 300 mm from an extractor, to prevent recirculation of products.
- Condensing flue materials
- When flue gas falls below its dew point, the flue must resist acidic condensate; stainless steel or polypropylene is used instead of conventional mild steel.
- Gas family definition
- IEC/EN 437 groups gases into families and test gases. Approval applies only to the family and pressure declared on the appliance data plate.
- EN 1775 scope
- The European standard for gas pipework installations in buildings, covering design, materials, installation, testing, and commissioning up to specified pressure limits.
- ATEX zoning
- Hazardous areas are classified into zones by the frequency and duration of explosive gas atmospheres, which determines the permitted electrical equipment category.
- Manufacturer instructions status
- They form part of the compliance basis for installation and maintenance; any deviation needs an engineering assessment and a written record.
- Tightness test procedure
- Pressurise with air or inert gas, allow temperature stabilisation, then measure pressure drop over a defined period against the permitted allowance for the pipe volume.
- Gas detection alarm settings
- Typical settings are 10 % of the lower explosive limit for warning and 20 % for action or automatic shutdown, with calibration checked periodically.
- Hot work permit controls
- Requires gas-free certification, continuous gas monitoring, fire watch during work and a defined period after, and isolation of the gas system.
- Strength versus tightness test
- The strength test runs at a higher pressure, typically 1.5 times design, to prove integrity; the tightness test follows at operating pressure to prove no leakage.
- Excess air from oxygen
- For natural gas, about 5 % oxygen in flue gas corresponds to roughly 30 % excess air; the relationship is used to set burner air during commissioning.
- Gas rate check
- Timing a known volume on the meter confirms rated input. A deviation beyond about 5 % from the data plate points to pressure, orifice, or calorific value issues.
- Regulator lock-up pressure
- The downstream pressure reached at zero flow when the regulator seat closes. A rising lock-up pressure indicates seat leakage and requires servicing.
- MTBF and availability
- MTBF is operating time divided by failure count. Availability is MTBF divided by MTBF plus mean time to repair, used to prioritise maintenance and spares.
- Simple payback
- Capital cost divided by annual savings. It ignores the time value of money, so it is used with net present value for project decisions.
- Degree-day load analysis
- In heating-dominated buildings, gas consumption is proportional to heating degree days; deviations from the trend reveal control faults or envelope problems.