Craftsman Information Device Operation flashcards
Craftsman Information Device Operation · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Byte and bit
- A bit is one binary digit (0 or 1); a byte is 8 bits. Storage and file sizes are quoted in bytes, while network speeds are usually quoted in bits per second.
- Unique record key
- A field or combination that identifies exactly one record, such as a serial or job number. Duplicate keys cause overwrites during sync and make records impossible to separate later.
- UTC timestamp storage
- Records store time in Coordinated Universal Time and display a local offset. This keeps ordering correct across time zones and daylight-saving changes when devices from several sites sync together.
- Offline write queue
- A local list of records awaiting sync, each tagged pending, sent, or confirmed. Without state tags, a reconnect can resend records and create silent duplicates.
- Audit trail fields
- The minimum audit entry holds the user, device ID, timestamp, field changed, old value, and new value. The old value is what makes a correction reversible.
- Data classification tiers
- Records are labeled public, internal, confidential, or restricted. The tier sets encryption, sharing, and retention rules, so a device holding restricted data must encrypt at rest.
- Factory reset consequence
- A factory reset erases local records and credentials but leaves server-side data untouched. Any unsynced work is lost, so export or confirm sync before resetting.
- Automatic network time
- The device sets its clock from the network instead of manual entry. Drift beyond about two minutes breaks timestamp ordering and can invalidate token-based sign-in.
- Firmware update conditions
- Apply firmware only on mains power or a battery above 50 percent, and never interrupt the write phase. An interrupted flash can leave the unit unusable.
- Enrollment profile
- A management package that pushes Wi-Fi settings, certificates, and app configuration to the device. Failed application usually means an expired certificate or wrong enrollment token.
- Least-privilege roles
- Operators, supervisors, and administrators get only the permissions their task needs. Administrator accounts are reserved for configuration, not routine data entry.
- Setup acceptance test
- Before handover, capture one record, sync it, retrieve it on the server, and confirm the audit entry shows the right user, device, and timestamp.
- Start-of-shift checks
- Confirm charge or swap the battery, verify network and sync status, confirm the pending queue is empty, then open the assigned work list before capturing any data.
- End-of-shift sync
- Submit open records, force a sync, confirm zero pending items, log out, and place the device on charge in its assigned location.
- Work-order state flow
- Orders move assigned, in progress, paused, complete, closed. Skipping a state or closing with open sub-tasks creates reconciliation gaps at shift end.
- Barcode scan distance
- Hold the scanner 10 to 25 cm from the label with the beam roughly perpendicular. Repeated no-reads usually indicate a damaged or low-contrast label.
- Written shift handover
- Handover records open items, device condition, and pending syncs in writing or in-app. Verbal-only handover loses exceptions and leaves the next operator without context.
- Point-of-failure exception
- When a step cannot be completed, record the reason code and photo evidence at that moment. Reconstructing exceptions later produces inaccurate records.
- Double-entry verification
- High-consequence fields such as serial numbers, quantities, and measurements are entered twice or scanned instead of typed. A mismatch between entries blocks submission.
- Form-level validation
- Required fields, min and max ranges, and pattern masks catch most entry errors before the record is saved, rather than after it reaches the server.
- Unit-with-value rule
- Every measurement is stored with its unit, such as mm, kg, or degrees Celsius. Mixing unit systems in one field is a frequent cause of recalls and rework.
- Correction record protocol
- Submitted values are never overwritten. A correction record references the original and carries a reason and approver, so the history stays intact and auditable.
- Search narrowing order
- Start with the unique key such as serial or job number, then narrow by date range, then use free text. Free-text-only searches return false matches.
- Look-alike serial check
- Before acting on a retrieved record, confirm the key and date match the intent. Serials differing by one character are a known source of wrong-record actions.
- Fault isolation order
- Check power and charge, then connections and card seating, then network, then application, then permissions. Fix the lowest layer before moving upward.
- Forced restart procedure
- If the device will not respond, charge it 30 minutes on a known-good charger, then hold power for 10 to 15 seconds. No response suggests battery or hardware failure.
- Sync failure checklist
- Check signal strength, server address, certificate validity, and account lock status, then retry. Record the error code before clearing it for escalation.
- Scanner no-read test
- Clean the window, inspect label contrast and damage, then scan a known-good label. If that also fails, the scanner needs recalibration or escalation.
- Escalation data package
- Include device serial, firmware version, error code, time of fault, steps already tried, and whether data is at risk. Missing details delay repair.
- Lithium battery hazard
- Never puncture, crush, or charge a lithium battery below 0 degrees Celsius. A swollen, hot, or leaking battery goes to a fire-resistant area and is reported.
- Ex-rated device rule
- In hazardous zones, only intrinsically safe certified devices may be used. Standard units must never be substituted, and the certification label must stay legible.
- Record retention period
- Regulated records are kept for the period set by the applicable standard or contract. Deleting them early is a compliance breach even when the data looks obsolete.