KY Pesticide Applicator study materials
KY Pesticide Applicator study resources

Calibration That Reads 19 Instead of 15

KY Pesticide Applicator · Put your knowledge to work in context.

All case studies

Calibration That Reads 19 Instead of 15

You are calibrating a 20-foot boom sprayer with 12 nozzles on 20-inch spacing before a preemergence corn herbicide. The label requires 1.5 qt of product per acre in a minimum of 15 gallons of carrier per acre. Your target is 15 GPA at 4 mph and 40 psi. Using the 1/128-acre method with a 204-foot course, you catch these volumes per nozzle, in ounces: 17, 18, 17, 27, 18, 17, 18, 26, 17, 17, 18, 17. The tank is 300 gallons, the nozzles are two seasons old, and there are no spare tips on the truck. Tomorrow's field is 120 acres, with wind forecast at 4-7 mph.

1. What is your actual output, and what goes wrong if you fill the tank as if you were at 15 GPA?

Read the worked answer

The 1/128-acre method: at 20-inch spacing, each nozzle covers 1/128 acre over 204 feet of travel, so ounces caught equals GPA.

  • Average catch = 227 oz across 12 nozzles = 18.9 oz, so about 18.9 GPA, roughly 26% above the 15 GPA target.
  • Carrying capacity falls: 300 gal / 18.9 GPA = 15.9 acres per tank, not the 20 you would expect at 15 GPA.
  • The dangerous mistake: mixing 300 gallons for 20 acres (20 x 1.5 qt = 30 qt of product) and then covering only 15.9 acres delivers 30 qt / 15.9 ac = 1.89 qt/acre - 26% over the labeled rate. That is an off-label application, and on a preemergence herbicide it is exactly the recipe for corn injury in the overlapping or slow-down areas.
  • The good news: 18.9 GPA is legal. The label sets a 15-gallon minimum carrier volume, so more water is allowed; the product rate is per acre, not per gallon of water. The error is in the mixing math, not in the carrier.

Also look at the spread, not just the average. Most nozzles read 17-18 oz, which would put you near 17-18 GPA. Two nozzles read 27 and 26 oz - about 50% above their neighbors. An average hides that; a farmer sees it as streaks of over-application and streaks of weed escapes.

2. Diagnose the two high nozzles and give the correction you can actually make before tomorrow, including the tank mix for 300 gallons.

Read the worked answer

Diagnosis:

  • Two adjacent-ish nozzles running 50% high with everything else consistent is a hardware problem, not a pressure problem. A pressure error would move all 12 nozzles together (flow varies with the square root of pressure, so a uniform 26% over-rate implies about 1.6x the set pressure, not two outliers).
  • Likely causes: worn or eroded orifice, a damaged or missing tip, a partially backed-off cap, or a cracked seat. Worn tips also produce finer droplets, which is a drift problem on top of a rate problem.

Fix before tomorrow:

  1. Pull those two tips and compare them against the catalog flow rate at 40 psi. If they are worn or damaged, replace them - and if the set is two seasons old, price a full set, because the other ten are already reading high against the 15 GPA target.
  2. Check the spray pattern on a flat surface or spray table; streaks confirm a worn tip.
  3. Recalibrate after replacing, with clean screens.

If no spares arrive: spray at the measured 18.9 GPA and recalibrate the mixing math.

  • 300 gal / 18.9 GPA = 15.9 acres per tank.
  • Product: 15.9 ac x 1.5 qt/ac = 23.8 qt, about 5.95 gal per tank.
  • Measure the product, not the acres. Fill half the water, add product with agitation running, then top to 300 gallons.

Then recheck the two bad nozzles after the first load - if they are damaged, they will not hold calibration.

3. Tomorrow's wind is 4-7 mph. What application-technique decisions still need to be made, given the equipment condition?

Read the worked answer

A legal wind speed does not make a worn boom safe.

  • Droplet size: worn orifices shift the spectrum finer. Combined with 40 psi on a preemergence pass, that raises the fine-droplet fraction and the off-target risk. Lower pressure only within the nozzle's rated range, and prefer switching to a drift-reducing (air-induction or extended-range) tip sized for the actual GPA.
  • Boom height: set it per the tip's rated height above the target - typically around 20 inches for a flat-fan on 20-inch spacing. Higher boom equals more time aloft and more drift plus more overlap error; check the whole boom is level, since a bent section is another way to get streaks.
  • Speed: hold a constant 4 mph. Slowing down silently raises GPA; speeding up cuts it and changes the pattern. Use the tachometer or GPS, not feel.
  • Buffers and sensitive areas: walk the downwind edge before starting. Identify any well, pond, dwelling, apiary, or organic field within the label buffer, and add margin if the wind has any component toward them. Stop if the wind gusts above the label limit, and watch for the evening inversion as the day cools.
  • Field operations: keep the sprayer out of overlaps at headlands and waterways, and shut off sections rather than doubling back over the same strip.

Bottom line: the calibration error is fixable tonight with the right arithmetic and two new tips. The technique decisions - tip selection, boom height, speed, buffers - are what determine whether tomorrow's 120 acres get sprayed legally or become a drift complaint.